background image

12

307363

Troubleshooting

WARNING

To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.

Before servicing this equipment always make sure to
relieve the pressure.

Check all possible problems and solutions before
disassembling the heater.

PROBLEM

CAUSE

SOLUTION

Heater will not heat

No current.

Check circuit, fuses.

Faulty circuit board.

Replace the cover and circuit board

assembly (20).

Burned out heater element.

Replace the housing.

Temperature too low

Fluid requires more warmup time.

Increase warmup time.

Wrong temperature setting.

Adjust the knob.

Flow rate too high.

Reduce flow rate or use two

heaters.

Clogged fluid passages.

Clean. Flush regularly.

Faulty circuit board.

Replace the cover and circuit board

assembly (20).

Temperature too high

Wrong temperature setting.

Adjust the knob.

Faulty circuit board.

Replace the cover and circuit board

assembly (20).

Too much pressure drop / fluid will
not flow

Flow rate too high.

Reduce flow rate or use two heat-

ers.

Clogged fluid passages.

Clean. Flush regularly.

Leakage from end plates

Loose bolts, damaged seals.

Tighten or replace seals.

Содержание 226816

Страница 1: ...Hazardous Locations Temp Code identification number T3C See the Technical Data on page 20 for additional information on this code US WARNING Hazard of Using Fluids Containing Halogenated Hydrocarbons...

Страница 2: ...ing the equipment D Use the equipment only for its intended purpose If you are uncertain about usage call your Graco distributor D Do not alter or modify this equipment Use only genuine Graco parts an...

Страница 3: ...stem D Always have the tip guard and the trigger guard on the gun when spraying D Be sure the gun trigger safety operates before spraying D Lock the gun trigger safety when you stop spraying D Follow...

Страница 4: ...t lights in the spray area D Do not smoke in the spray area D Do not turn on or off any light switch in the spray area while operating or if fumes are present D Do not operate a gasoline engine in the...

Страница 5: ...or trailer is grounded to a true earth ground also 5 Air compressor or hydraulic power supply follow manufacturer s recommendations 6 Spray gun grounding is obtained through connec tion to a properly...

Страница 6: ...ied person install and wire the heater 4 Be sure the installation is in compliance with all local state and national codes 5 Do not install any shutoff devices downstream from the heater WARNING Heat...

Страница 7: ...he Hoses Connect the fluid lines to the 1 2 npt f inlet and outlet of the heater See the Typical Installation on page 6 To minimize heat loss fluid lines should be insulated when they are especially l...

Страница 8: ...praying D check or service any of the system equipment D or install or clean the spray tip 1 Lock the gun trigger safety 2 Shut off the main power to the heater 3 Circulate the fluid for at least 10 m...

Страница 9: ...ely closed circulating system use a director valve L attached to the pump intake to purge the system See the Typical Installation on page 6 Setting the Heater Controls See Fig 4 NOTE The knob settings...

Страница 10: ...g from the highest one Multiply that result by 0 90 Subtract the new result from the highest viscosity reading Find this number on your temperature and viscos ity records This is the temperature to us...

Страница 11: ...ystem or heater is not in use 3 If the system runs dry refill it immediately before fluid can dry in it Or flush the system thoroughly if you are not going to use it immediately 4 To drain the fluid f...

Страница 12: ...ut heater element Replace the housing Temperature too low Fluid requires more warmup time Increase warmup time Wrong temperature setting Adjust the knob Flow rate too high Reduce flow rate or use two...

Страница 13: ...307363 13 Notes...

Страница 14: ...20b to disconnect the black or white input wire R Discard the screw and lockwasher 4 Disengage the wiring harness female connector 20e from male connector in lower left hand corner of the circuit boar...

Страница 15: ...307363 15 Service Fig 10 20a 20b 20d 20c 20g 1 3 2 1 20f 2 3 White White 120V Black 240V Apply thermal grease Graco Part No 110009 to tip 4 W 20e 20h 4 R X 2...

Страница 16: ...t with a new lamp 3 Screw the lens cap onto the socket 50 until the o ring in the lens cap contacts the socket then turn the lens cap 1 2 to 1 turn more to ensure a good seal WARNING The terminals 46...

Страница 17: ...307363 17 Notes...

Страница 18: ...ee important repair and assembly information on pages 14 16 27 4 46 17 1 5 24 19 19 49 47 48 50 28 30 48 46 22 15 18 8 NOTE See page 11 for important tightening sequence and torque values for the endc...

Страница 19: ...8 SCREW cap hex hd 7 16 x 2 in long 36 17 157974 WASHER flat steel 3 16 in screw size 2 18 166412 PACKING o ring PTFE 2 19 167002 INSULATOR heat 8 20 222217 COVER CIRCUIT BOARD ASSY 120 V Model 226816...

Страница 20: ...14 2 mm2 12 ft 3 7 m Working pressure up to 3000 psi 21 MPa 207 bar maximum Thermometer range 0 to 250_F 18 to 121_C Temperature range 80 to 190_F 26 to 88_C Weight 37 5 lb 17 kg This heater has a sur...

Страница 21: ...226816 Series F For 120 Volt Heater 2 1 2 3 1 4 NEGIN 1 RAMP 5 VS 8 VSYNC 3 POSIN 2 CRAMP 7 GND 6 OUT 1 2 222214j Model 226819 Series F For 240 Volt Heater 2 1 2 3 1 4 NEGIN 1 RAMP 5 VS 8 VSYNC 3 POSI...

Страница 22: ...22 307363 Dimensions Mounting Hole Layout 4 in 102 mm 6 5 in 165 mm 0 41 in 10 4 mm dia...

Страница 23: ...307363 23 Notes...

Страница 24: ...breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or pr...

Отзывы: