6 308-230

Installation

General Information

1. The Typical Installations shown on pages 7 and

8 are only a guide for selecting and installing sys-

tem components. Contact your Graco distributor or

Graco Technical Assistance (see back page) for

assistance in planning a system to suit your needs.

2. Always use Genuine Graco Parts and Accesso-

ries, available from your Graco distributor. Refer to

the Product Data Sheet for the pump, Form No.

305–528. If you supply your own accessories, be

sure they are adequately sized and pressure rated

for your system.

3. Use a compatible, liquid thread sealant or 

tape on all male threads. Tighten all connections

firmly to avoid air or fluid leaks. 

Do not over-

tighten plastic threads.

4. Reference numbers and letters in parentheses re-

fer to the callouts in the Figures and the parts lists

on pages 12–17.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can

cause serious injury or death if splashed

in the eyes or on the skin, inhaled, or

swallowed.

1. Read

 TOXIC FLUID HAZARD

 on page 3.

2. Use fluids and solvents which are compatible

with the equipment wetted parts. Refer to the

Technical Data

 section of all equipment manu-

als. Read the fluid and solvent manufacturer’s

warnings.

WARNING

Accessories

A bleed-type master air valve (B) is required in

your system to relieve air trapped between this

valve and the pump. Trapped air can cause the

pump to cycle unexpectedly, which could result in

serious injury, including splashing in the eyes or on

the skin, injury from moving parts, or contamination

from hazardous fluids.

A fluid drain valve (J) is required in your system to

relieve pressure in the hose if it is plugged. (The

fluid recirculation valve supplied with Models

236–870, 224–833, and 236–412 will serve this

purpose.) The drain valve reduces the risk of seri-

ous injury, including splashing in the eyes or on the

skin, or contamination from hazardous fluids when

relieving pressure. Install the valve close to the

pump’s fluid outlet.

WARNING

1. Install the air line accessories as shown in Figs. 3

and 4. Mount these accessories on the wall or on a

bracket. Be sure the air line supplying the acces-

sories is grounded.
a. Locate one bleed-type master air valve (B)

close to the pump and use it to relieve trapped

air. See the 

WARNING

 above. Locate the oth-

er master air valve (E) upstream from all air

line accessories and use it to isolate them dur-

ing cleaning and repair.

b. The air line filter (F) removes harmful dirt and

moisture from the compressed air supply.

2. Install an electrically conductive, flexible air hose

(C) between the accessories and the pump. Use a

minimum 1/4” (6.3 mm) ID air hose. Screw an air

line quick disconnect coupler (D) onto the end of

the air hose (C)

.

 Do not connect the coupler (D) to

the air inlet fitting (22, see Figs. 1 and 2) yet.

Hose Connections

1. Read the entire spray gun manual before connect-

ing the hoses and operating the sprayer.

2. Connect a fluid hose (N) between the pump fluid

outlet fitting and the fluid inlet of the spray gun (R).

See Figs. 3 and 4.

3. Connect an electrically conductive air hose (P) be-

tween the outlet fitting of the gun air regulator (G)

and the air inlet of the spray gun (R).

PTFE

PTFE

PTFE

Содержание 224-833

Страница 1: ...t Pressure Model 236 870 Series A Pail Mount Unit with Fluid Regulator Model 224 833 Series B Pail Mount Unit with Fluid Regulator and Hose Kit Model 236 412 Series A Pail Mount Unit with Surge Tank a...

Страница 2: ...Graco distributor Do not alter or modify this equipment Use only genuine Graco parts and accessories Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum...

Страница 3: ...and result in a fire or explosion and serious injury Ground the equipment Refer to Grounding on page 9 If there is any static sparking or you feel an electric shock while using this equipment stop pum...

Страница 4: ...depth Tighten the nut securely 3 On Models 236 870 and 224 833 assemble the Fluid Regulator Kit items 17 21 24 and 32 as shown in Fig 1 4 Attach the pail cover 2 to a pail of fluid using the thumbscr...

Страница 5: ...ts full depth then tighten the nut secure ly with a wrench Push the 0 5 in 13 mm OD flexible tube 29 into the elbow 30 to its full depth then tighten the nut secure ly with a wrench Push the other end...

Страница 6: ...kin injury from moving parts or contamination from hazardous fluids A fluid drain valve J is required in your system to relieve pressure in the hose if it is plugged The fluid recirculation valve supp...

Страница 7: ...connect E Master Air Valve for accessories F Air Line Filter G Gun Air Regulator H Pump Air Regulator J Fluid Drain Valve required K Fluid Recirculation Line L Fluid Suction Line M Fluid Regulator and...

Страница 8: ...Valve required L Fluid Suction Line M Surge Tank and Filter N Gun Fluid Supply Hose P Gun Air Supply Hose R Air Spray Gun S Wall Bracket Y Ground Wire included See page 9 for grounding instructions Ai...

Страница 9: ...to the pump grounding strip Z Connect the clamp end of the ground wire to a true earth ground Fig 5 04963 Y Z 34 2 Air and fluid hoses Use only electrically conduc tive hoses 3 Spray gun The spray gu...

Страница 10: ...e sure the pump is properly grounded Read FIRE OR EXPLOSION HAZARD on page 3 2 Check all fittings to be sure they are tight Be sure to use a compatible liquid thread sealant or tape on all male thread...

Страница 11: ...supplied with Models 236 870 224 833 and 236 412 drains unused fluid back into the fluid container ensuring an even flow at the gun Recirculation also provides gentle fluid agita tion To recirculate...

Страница 12: ...rd part 1 111 885 GASKET Vitonr alternative to EPDM shipped loose 1 18 237 534 VALVE ball 3 8 npt m x f sst 1 19 111 928 TEE 3 8 npt f run x 3 8 npt m branch sst 1 20 112 026 ELBOW street 3 8 npt m x...

Страница 13: ...Part of item 17 17a 17b 1 3 4 2 Torque to 35 55 in lb 4 0 6 2 N m Do not over torque Torque to contact plus 1 2 turn Insert tube into elbow 14 to full depth and tighten nut securely with wrench Inser...

Страница 14: ...308 325 1 18 237 534 VALVE ball 3 8 npt m x f sst 1 19 111 928 TEE 3 8 npt f run x 3 8 npt m branch sst 1 21 188 089 NIPPLE 3 8 npt x 3 8 18 6 sf sst 1 22 169 971 FITTING air line 3 8 npt m 1 23 188 0...

Страница 15: ...hten nut securely with wrench Insert tube into elbow 15 to full depth and tighten nut securely with wrench Insert tube into connector 16 to full depth and tighten nut securely with wrench 5 6 7 28 1 2...

Страница 16: ...npt x 3 8 npt sst 1 22 169 971 FITTING air line 3 8 npt m 1 23 188 077 NIPPLE 1 4 18 npt x 1 4 18 6 sf cst 1 24 188 091 NIPPLE 1 2 npt x 3 8 18 6 sf cst Models 236 628 and 236 414 only 1 188 380 NIPP...

Страница 17: ...0 12 13 14 17 23 24 25 26 26 4 5 6 39 40 A A 3 Part of item 17 17a 17b 1 3 4 2 Torque to 35 55 in lb 4 0 6 2 N m Do not over torque Torque to contact plus 1 2 turn Insert tube into elbow 14 to full de...

Страница 18: ...mm Pail is not included Maximum pail outer diameter is 12 125 in 308 mm 13 1 in 332 7 mm Model 236 412 Models 236 870 and 224 833 17 5 in 444 5 mm Wall Mounting Hole Layout 5 in 127 mm 0654 Four 0 43...

Страница 19: ...236 869 acetal Maximum Fluid Working Pressure 100 psi 0 7 MPa 7 bar Air Pressure Operating Range 15 100 psi 104 700 kPa 1 7 bar Pump Air Inlet Size 1 4 npt f Pump Fluid Inlet and Outlet Size 3 8 npt f...

Страница 20: ...ed to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty mu...