background image

10 308-230

Operation

Pressure Relief Procedure

PRESSURIZED EQUIPMENT HAZARD

The system pressure must be manually relieved to

prevent the system from starting or spraying acci-

dentally. To reduce the risk of an injury from acci-

dental spray from the gun, splashing fluid, or mov-

ing parts, follow the 

Pressure Relief Procedure

whenever you:

are instructed to relieve the pressure,

stop spraying,

check or service any of the system equipment,

or install or clean the spray tips.

WARNING

1. Shut off the air to the pump.

2. Trigger the spray gun.

3. Open the fluid drain valve to relieve all fluid pres-

sure, having a container ready to catch the drain-

age.

Flush the Pump Before First Use

The pump was tested in water. If the test solution

could contaminate the fluid you are pumping, flush the

pump thoroughly with a compatible solvent. Follow the

procedure in 

Starting and Adjusting the Pump.

Starting and Adjusting the Pump

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can

cause serious injury or death if splashed

in the eyes or on the skin, inhaled, or

swallowed. Do not lift a pump under pressure. If

dropped, the fluid section may rupture. Always fol-

low the 

Pressure Relief Procedure

 above before

lifting the pump.

WARNING

1. Be sure the pump is properly grounded. Read

FIRE OR EXPLOSION HAZARD

 on page 3.

2. Check all fittings to be sure they are tight. Be sure

to use a compatible liquid thread sealant or 

tape on all male threads. Tighten the fluid inlet and

outlet fittings snugly. Do not overtighten the fittings

into the pump.

3.

On pail mount units, 

place the suction tube in a

pail of fluid and attach the pail cover using the

thumbscrews. Tighten securely.

On wall mount units,

 install the suction tube and

bung plug in the fluid supply drum as explained on

page 5.

4. Make sure the air regulators (G and H) and bleed

valves (B and E) are closed. Open the fluid drain

valve (J).

5. Connect the air line coupler (D) to the air inlet fit-

ting.

6. With the gun air regulator (G) closed, open the

bleed-type master air valves (B, E) and the pump

air regulator (H).

7. Allow the pump to cycle slowly until all air is

pushed out of the recirculation line and the pump

is primed.

8. Point the spray gun (R) into a grounded metal pail,

holding a metal part of the gun firmly to the side of

the pail.

9. Trigger the air spray gun. Open the gun air regula-

tor (G) and close the fluid drain valve (J). Allow the

pump to cycle slowly until all air is pushed out of

the fluid hose and gun.

If you are flushing, run the pump long enough to

thoroughly clean the pump and hoses. Close the

air regulator. Remove the suction tube from the

solvent and place it in the fluid to be pumped.

PTFE

PTFE

PTFE

Содержание 224-833

Страница 1: ...t Pressure Model 236 870 Series A Pail Mount Unit with Fluid Regulator Model 224 833 Series B Pail Mount Unit with Fluid Regulator and Hose Kit Model 236 412 Series A Pail Mount Unit with Surge Tank a...

Страница 2: ...Graco distributor Do not alter or modify this equipment Use only genuine Graco parts and accessories Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum...

Страница 3: ...and result in a fire or explosion and serious injury Ground the equipment Refer to Grounding on page 9 If there is any static sparking or you feel an electric shock while using this equipment stop pum...

Страница 4: ...depth Tighten the nut securely 3 On Models 236 870 and 224 833 assemble the Fluid Regulator Kit items 17 21 24 and 32 as shown in Fig 1 4 Attach the pail cover 2 to a pail of fluid using the thumbscr...

Страница 5: ...ts full depth then tighten the nut secure ly with a wrench Push the 0 5 in 13 mm OD flexible tube 29 into the elbow 30 to its full depth then tighten the nut secure ly with a wrench Push the other end...

Страница 6: ...kin injury from moving parts or contamination from hazardous fluids A fluid drain valve J is required in your system to relieve pressure in the hose if it is plugged The fluid recirculation valve supp...

Страница 7: ...connect E Master Air Valve for accessories F Air Line Filter G Gun Air Regulator H Pump Air Regulator J Fluid Drain Valve required K Fluid Recirculation Line L Fluid Suction Line M Fluid Regulator and...

Страница 8: ...Valve required L Fluid Suction Line M Surge Tank and Filter N Gun Fluid Supply Hose P Gun Air Supply Hose R Air Spray Gun S Wall Bracket Y Ground Wire included See page 9 for grounding instructions Ai...

Страница 9: ...to the pump grounding strip Z Connect the clamp end of the ground wire to a true earth ground Fig 5 04963 Y Z 34 2 Air and fluid hoses Use only electrically conduc tive hoses 3 Spray gun The spray gu...

Страница 10: ...e sure the pump is properly grounded Read FIRE OR EXPLOSION HAZARD on page 3 2 Check all fittings to be sure they are tight Be sure to use a compatible liquid thread sealant or tape on all male thread...

Страница 11: ...supplied with Models 236 870 224 833 and 236 412 drains unused fluid back into the fluid container ensuring an even flow at the gun Recirculation also provides gentle fluid agita tion To recirculate...

Страница 12: ...rd part 1 111 885 GASKET Vitonr alternative to EPDM shipped loose 1 18 237 534 VALVE ball 3 8 npt m x f sst 1 19 111 928 TEE 3 8 npt f run x 3 8 npt m branch sst 1 20 112 026 ELBOW street 3 8 npt m x...

Страница 13: ...Part of item 17 17a 17b 1 3 4 2 Torque to 35 55 in lb 4 0 6 2 N m Do not over torque Torque to contact plus 1 2 turn Insert tube into elbow 14 to full depth and tighten nut securely with wrench Inser...

Страница 14: ...308 325 1 18 237 534 VALVE ball 3 8 npt m x f sst 1 19 111 928 TEE 3 8 npt f run x 3 8 npt m branch sst 1 21 188 089 NIPPLE 3 8 npt x 3 8 18 6 sf sst 1 22 169 971 FITTING air line 3 8 npt m 1 23 188 0...

Страница 15: ...hten nut securely with wrench Insert tube into elbow 15 to full depth and tighten nut securely with wrench Insert tube into connector 16 to full depth and tighten nut securely with wrench 5 6 7 28 1 2...

Страница 16: ...npt x 3 8 npt sst 1 22 169 971 FITTING air line 3 8 npt m 1 23 188 077 NIPPLE 1 4 18 npt x 1 4 18 6 sf cst 1 24 188 091 NIPPLE 1 2 npt x 3 8 18 6 sf cst Models 236 628 and 236 414 only 1 188 380 NIPP...

Страница 17: ...0 12 13 14 17 23 24 25 26 26 4 5 6 39 40 A A 3 Part of item 17 17a 17b 1 3 4 2 Torque to 35 55 in lb 4 0 6 2 N m Do not over torque Torque to contact plus 1 2 turn Insert tube into elbow 14 to full de...