5
307-488
Setup
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE OR EXPLOSION
HAZARD on page 4.
1.
Pump: check ground wire and clamp for proper
installation. To install ground wire and clamp. See
Fig. 1. Loosen grounding lug locknut (W) and
washer (X). Insert one end of a 1.5 mm
(12 ga)
minimum ground wire (Y) into the slot in lug (Z)
and tighten the locknut securely. Connect the other
end of the wire to a true earth ground. To obtain
ground wire and clamp, order Graco Part No.
238–909 Ground Wire Assembly.
Fig. 1
W
X
Y
Z
0864
2.
Air and fluid hoses: use only electrically conductive
hoses.
3.
Air compressor: follow manufacturer’s recommen-
dations.
4.
Spray gun: ground through connection to a prop-
erly grounded fluid hose and pump.
5.
Fluid supply container: follow your local code.
6.
Object being sprayed: follow your local code.
7.
Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
8.
To maintain grounding continuity when flushing or
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded
metal pail,
then trigger the gun.