background image

Installation 

6

308048N

Grounding

Proper grounding is an essential part of maintaining a 

safe system. 

Check your local electrical code for detailed grounding 

instructions for your area and type of equipment. Be 

sure to ground all of this equipment:

Pump

: use a ground wire and clamp as shown to 

the right.

Hydraulic hoses and fluid outlet hoses

: use only 

electrically conductive hoses.

Hydraulic power supply and air compressor

follow manufacturer’s recommendations. 

Spray gun

: obtain grounding through connection 

to a properly grounded fluid hose and pump.

Fluid supply container

: according to local code.

Object being sprayed

: according to local code.

Any pails used when flushing

: Use only metal, 

grounded pails when flushing. Make firm 

metal-to-metal contact between the metal part of 

the spray gun and the pail. Use the lowest possible 

pressure.

• To maintain grounding continuity when flushing or 

relieving pressure, always hold a metal part of the 

gun firmly to the side of a grounded metal pail, and 

then trigger the spray gun. 

F

IG

. 2 ___________________________________________

The equipment must be grounded to reduce the risk 

of static sparking. Static sparking can cause fumes 

to ignite or explode. Grounding provides an escape 

wire for the electric current.

A

B

Содержание 223646

Страница 1: ...ofessional use only Model 223646 Series C and D 1500 psi 10 MPa 103 bar Maximum Hydraulic Fluid Input Pressure Important Safety Instructions Read all warnings and instructions in this manual before us...

Страница 2: ...ngs has been updated This cylindrical design replaces the square housing design previously used There is no performance change associated with this update If replacement of a square housing is necessa...

Страница 3: ...damaged parts immediately with genuine manufacturer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure...

Страница 4: ...ug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail lin...

Страница 5: ...s seals When starting up the hydraulic system open the return line shutoff valve first NOTICE Keep the hydraulic system clean To reduce the risk of damaging the hydraulic power supply blow out all hyd...

Страница 6: ...ded fluid hose and pump Fluid supply container according to local code Object being sprayed according to local code Any pails used when flushing Use only metal grounded pails when flushing Make firm m...

Страница 7: ...e the pressure 3 Stop the pump at the bottom of its stroke 4 Disconnect the displacement pump hoses Disconnect the hydraulic hoses and plug all hydraulic connections and lines to prevent contamination...

Страница 8: ...tainer 30b Remove the trip rod 31 from the piston 30a 19 Remove the trip rod locknut 27 and piston stop 28 If the piston is replaced remove the spring 26 to use in the new piston 20 Remove the bearing...

Страница 9: ...12 Install the end cap 47 using thread sealant on the socket screws 51 13 Lubricate the threads of the tie rods 57 and install them with lockwashers 52 If the crown nuts 44 were removed reinstall them...

Страница 10: ...t be positioned with joints opposed Lips must face up toward top of motor Model 235345 use only one seal 23 Torque to 70 80 ft lb 95 108 N m Apply thread lubricant to lower threads Concave surface fac...

Страница 11: ...1 32 26 30a 17 30b 27 28 56 54 54a 3 3a 1 20 16 11 25 24 23 29 57 33 33 24 2 15 14 21 13 12 19 18 A A B B 4342 40 41 39 9 30c Model 223646 Series C NOTE See the service section for important torque an...

Страница 12: ...NUT hex jam 5 8 18 4 20 101577 SCREW machine hex hd No 10 20 x 0 375 in 1 21 110800 O RING buna N 1 23 186223 BEARING piston bronze filled PTFE 1 24 110795 SEAL u cup polyurethane 2 25 186218 HOUSING...

Страница 13: ...Parts Cylindrical Housings 308048N 13 Parts Cylindrical Housings Model 223646 Series D 25a b 30cX 30bX X30a...

Страница 14: ...am 5 8 18 4 20 101577 SCREW machine hex hd No 10 20 x 0 375 in 1 21 110800 O RING buna N 1 23 186223 BEARING piston bronze filled PTFE 1 24 110795 SEAL u cup polyurethane 2 25 20B232 KIT replacement h...

Страница 15: ...Hydraulic fluid consumption 1 gal 3 8 liter per 5 cycles Effective piston area 4 9 sq in 31 6 cm2 Piston rod diameter 2 5 in 64 mm Stroke length 4 69 in 119 1 mm Thrust at 1500 psi 10 MPa 103 bar 7300...

Страница 16: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRAN...