6
307552
Installation
5. Connect the dry air hoses (M) to the identically
labeled drum fittings using the special pin fitting (J)
and coupler (N). See Fig 3.
6. Attach a bushing (104) to one end of two of the air
supply hoses (103) and attach a bushing to each
end of the third air hose. See the Parts Drawing on
page 13.
7. Connect one air hose between the feed pump and
the 1/2 npt(f) air manifold on the side of the Foam-
Cat sprayer pump stand. Repeat for the other feed
pump.
8. Connect the hose with the two bushings between
the 1/2 npt(f) air inlet of the Air Dryer and a bleed–
type master air valve (E), required. Then connect
the main air supply line to the air valve.
9. Connect the ISO fluid hose between the 3/4 npt(f)
fluid outlet of the ISO feed pump and the 3/4 npt(f)
inlet of the corresponding displacement pump.
Repeat for the RES pumps.
M
05218
FIG.
3
KEY
A
Air Line
B
Air Line Filter
E
Bleed-type master valve
F
Air Dryer Ring
G
Nipple
H
Drum Air Fittings
J
Pin Fitting
K
Ball Valve
L
Bushing
M
Air Hose (Air Dryer)
N
Special Air Coupler
7
Pin Fitting
8
Air Control Valve
13
Air Line Coupler
103
Air Hoses (Pump)
104
Bushing
105
Air Dryer
WARNING
The special air line fitting (J) and coupler (N) are
designed to prevent accidentally coupling an
unregulated air supply hose to the container.
Unregulated air can overpressurize the container and
cause it to rupture, resulting in serious bodily injury
and property damage. If the coupler and fitting ever
needs to be replaced use only original Graco parts.