308081
5
Setup
General Information
NOTE:
Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE:
Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor. Refer to
the Product Data Sheet for your pump, Form No.
305789. If you supply your own accessories, be sure
they are adequately sized and pressure rated for your
system.
Fig. 2 is only a guide for selecting and installing sys-
tem components and accessories. Contact your Graco
distributor for assistance in designing a system to suit
your particular needs.
Prepare the Operator
All persons who operate the equipment must be
trained in the safe, efficient operation of all system
components as well as the proper handling of all fluids.
All operators must thoroughly read all instruction
manuals, tags, and labels before operating the equip-
ment.
Prepare the Site
The King pump requires 180 scfm (5.0 m
#
/min) of
compressed air while operating at 90 psi (0.6 MPa, 6
bar) air pressure and 60 cycles per minute. Ensure
that you have an adequate compressed air supply.
Refer to Fig. 2. Bring a compressed air supply line (A)
from the air compressor to the pump location. Be sure
all air hoses (A) are properly sized and pressure-rated
for your system. Use only electrically conductive
hoses. The air hose should have a 3/4 npsm(m)
thread.
Install a bleed-type shutoff valve (B) in the air line to
isolate the air line components for servicing. Install an
air line moisture trap and drain valve (C) to help re-
move moisture from the compressed air supply.
Keep the site clear of any obstacles or debris that
could interfere with the operator’s movement.
Have a grounded, metal pail available for use when
flushing the system.
Содержание 20:1 KING 231131