Installation
313212B
7
Install the Solenoid
NOTE:
The GFB Interface Module Kit does not include a
solenoid (SO). The solenoid is supplied with the gun
flush box kit. Install the solenoid in the interface module
as follows.
1.
Each gun flush box kit includes one solenoid (SO).
The GFB interface module can accommodate 1 or 2
solenoids. Install the solenoid(s) on the manifold at
the bottom rear of the enclosure. See F
NOTE:
on page 11. If you are using two gun
flush boxes, remove the two sealing screws (4) from the
solenoid manifold (8) before installing SO#2. Also
remove the plug (5) from the connector (15).
2.
Connect the wires from SO#1 to the right side of the
terminal strip (12), as indicated by the label (21); red
(+12V) to pin 9, black (COM) to pin 10. See F
3.
If using a second gun flush box, connect the wires
from SO#2 to the right side of the terminal strip (12),
as indicated by the label (21); red (+12V) to pin 11,
black (COM) to pin 12. See F
F
IG
. 7. Install Solenoid (two shown)
SO#1
SO#2
TI14282a
Solenoid is part of gun flush box kit; not
included with GFB Interface Kit.
1
1
1
F
IG
. 8. Connect Solenoid to Terminal Strip
21
12
TI14279a
Содержание 15V534