To select a preset register push the DATA control to highlight the preset number
digits. Turn the DATA control to increment the number to the desired register and
then push the DATA control again. To store the preset turn the DATA control until the
word “Store:” is highlighted. Next, push the DATA control. This will highlight the word
“go” as well. At this point turning the DATA control clockwise or counter-clockwise will
execute the store function. The display will briefly display “
***
Confirmed
***
” and
then return to the Channel Mode.
NOTE: A preamplifier will automatically store all of its current settings into a non-
volatile memory whenever power is removed. When power is restored the
preamplifier will retrieve these settings. This ensures that no settings are lost during
power line interruptions.
Preset Recall:
Registers 1 through 99 are available for user storage and recall.
Register number 0 can not be over-written and contains a "null" set-up. The "null"
setup sets all channels to the lowest gain setting, +48V off, phase reverse off and
deletes any channel groups. Pre-set register 0 is helpful when setting up for a new
session.
Note: when you recall a preset from the front panel of a preamplifier you are recalling
from that preamplifier only. If you recall a preset from the RCU a recall command will
be sent to all of the preamplifiers in the system.
On a preamplifier the recall menu will indicate:
*
Recall Preamp Preset
*
#:
01 Store: go
On the RCU the recall menu will indicate:
*
Recall System Preset
*
#:
01 Store: go
Recalling a preset is identical to storing a preset.
The following setup fields all appear on the last page of the Setup Mode:
ID:1 Peak:hld Contrast :126 Backlight: on
The Preamplifier ID:
This field allows one to select a unique identification for each
preamplifier in a system. The ID number also assigns channel numbers to the
preamplifier. For instance, ID 1 includes channels 1-8, ID 2 includes channels 9-16
and so on to ID 8 which includes channels 57-64. Pushing the DATA knob once
allows the ID number field to changed by rotating the DATA knob. Pushing the DATA
knob again saves the setting.