1. Remove the Needle Plate.
2. Rotate your Hook Assembly so that the
positioning guide is at the highest point during
rotation.
3. Attach your Hook Holder to your sewing
machine with a M5 X 10mm FHCS (don’t
tighten the screw during this step) with the
Hook Holder’s finger in the middle of the Hook
Assembly’s positioning guide.
4. Slide your Hook Holder away from the Hook
Assembly so there is about a 0.75mm gap
between the Hook Holder and the Hook
Assembly, and tighten the M5 X 10mm FHCS.
Tools Needed:
3mm Allen Wrench
Flat Head Screwdriver
Needle
Plate
Hook
Holder
M5 x 10mm
FHCS
|
Hook Holder
Q’nique 21: Service Manual
Hook Assembly
0.75mm Gap
between Hook
Holder and Hook
Assembly
Hook Assembly
Positioning
Guide
Hook Assembly
Positioning
Guide
5
Hook Holder
It’s hard to measure
so just make it so
tip of Hook Holder is
flush with Positioning
Guide Finger