GQ Electronics GMC-320 Plus Скачать руководство пользователя страница 6

 

Overview 

 
The.GQ  GMC-320  PLUS  digital  Geiger  Muller  Counter  is  designed  to  be  a  portable  and 
convenient  device.  It  can  be  used  as  industrial,  commercial  maintenance,  research, 
evaluation,  simulation  and  other  analytical  or  scientific  applications  in  areas  such  as 
industrial  plants,  public  utilities,  hospitals,  universities,  laboratories,  and  electronic  repair 
shops.  The  device  comes  with  built  in  audible  and  visual  signals  for  the  level  of  radiation 
detected. It can be used for radiation detection and monitoring both indoor and outdoor, as 
well as in other similar environments. It features automatic data recording. It can continually 
monitor the radiation and log the data each second into internal memory. When connected to 
a PC, software can download the radiation history data to the computer and the user is able 
to analyze those data later. The GQ GMC-320 Plus installed a high contrast black/white LCD 
module,  one front  LED  indicator  and  one  analog  data  port.  The  analog    data  port  can  be 
connected to any third party device application as data input.  
 
 
The  device  is  equipped  with  an  USB  port,  utilized  for  communication  and  external  power 
supply/charging of the internal rechargeable Li-Ion 3.6V/3.7V battery. 
 
The  GQ  GMC-320  Plus  internal  rechargeable  battery  can  be  charged  with  a  standard  wall 
adapter.  Using  the  adapters,  continuous  data  monitoring  is  possible.  Using  either  power 
adapter you will not have to worry about the batteries charge condition or any data loss. 
 
The main board also has a real time clock on board for time related data logging purposes. 
 
The  USB  port  communicates  with  the 

GQ  GMC-320  Plus  Soft  Geiger  Counter

  software 

and the 

GQ Geiger Counter Data Viewer

 software. 

 
The 

GQ GMC-320 Plus Soft Geiger Counter

 

software’s appearance is an exact copy of the 

GMC-320 hardware human interface. You can download it for free and experience the GMC-
320 user interface before you purchase the real hardware. 
 
The 

GQ  Geiger  Counter  Data  Viewer

  software  can  download  the  time  stamped  radiation 

(history) data from the unit and save it on a computer for future references and analysis. 
 
For professional data logging of radiation data, the 

GQ  Geiger  Counter  Data  Logger 

may 

be  downloaded  for  free.  An  even  more  advanced  version,  the 

GQ  Geiger  Counter  Data 

Logger PRO

 software may be purchased at low cost from GQ Electronics LLC. 

 

Specifications: 

 

Range of dose rate indications, µSv/h

 

 

 

0.00 to 327.99 

Range of exposure dose rate indications,mRem/h

 

0.00 to 32.99 

Range of gamma radiation energy MeV from 0.1 to 1.25  
Range of registered beta radiation energy MeV 

   

0.25 to 3.5  

Range of gamma radiation energy, MeV 

 

 

0.1 to 1.25 

Range of registered X-ray radiation energy MeV

   

0.03 to 3.0 

Reproducibility of indication 

 

 

 

20% 

Alarm levels by CPM

  

 

 

 

 

0 to 65535 (continuously) 

Alarm levels by uSv/h 

 

 

 

 

0.00 to 327.6 (continuously) 

Alarm levels by mRm/h

 

 

 

 

0.00 to 32.76 (continuously) 

Date indication

 

 

 

 

 

YYYY-MM-DD (continuously) 

Time indication 

 

 

 

 

HH-MM-SS (continuously) 

Elapsed time indication

 

 

 

 

99 years(maximum) 

Timed Count

   

 

 

 

 

1 Second to 256 days(programmable) 

Scheduled Timed Count

 

 

 

 

0 Second to 256 days(programmable) 

Radiation detection

:  

 

 

 

b

,

g,

 x

 

Detectable Radiation Range

:  

 

 

0.1 ~ 3 MeV  

Instrument Background

:  

 

 

 

< 0,2 pulses/s  

Working Voltage

 

 

 

 

3.6-3.7V  

Содержание GMC-320 Plus

Страница 1: ...GQ GMC 320 Plus Geiger Counter User Guide GQ Electronics LLC Revision 2 13 Sep 2017...

Страница 2: ...GQ Electronics LLC Revised for firmware 3 18 Re 2 00 Jan 2015 GQ Electronics LLC Revised for V4 firmware 4 00 Re 2 10 Jul 2015 GQ Electronics LLC Content revise Re 2 11 May 2016 GQ Electronics LLC Co...

Страница 3: ...t 14 Date and Time setting 15 Data Saving Setting 15 Threshold Data Saving Setting 16 Add Note or Add Location for data saving 16 Note Location Input 16 History data searching 17 History data menu 17...

Страница 4: ...com 28 Software 28 Auto Submit Data Protocol 28 Applications 29 Stationary Application 29 Other technical details you may want to know 29 Data Port 29 USB Port 30 Data collection time 30 Tube recover...

Страница 5: ...5 ACKNOWLEDGEMENTS TO BE FILLED...

Страница 6: ...l time clock on board for time related data logging purposes The USB port communicates with the GQ GMC 320 Plus Soft Geiger Counter software and the GQ Geiger Counter Data Viewer software The GQ GMC 3...

Страница 7: ...or mR h After GMC 320 turned on for one minute it will show the background radiation reading The background radiation reading in CPM indicates the nature radiation detected at that minute This readin...

Страница 8: ...0 second if no key is being pressed during this period 4 Now the unit is ready to use You should see the background CPM rate in absence of a radioactive source Note There is a transparent protective s...

Страница 9: ...ce manger you should see which COM port is assigned to the GMC 320 Plus See the example below Windows assigned COM3 to the GMC 320 Plus unit in this example For the data viewer or the data logger soft...

Страница 10: ...em upwards 4 In the menu mode while a popup message box is opened the S2 key changes the value by cycling through the predefined values S3 key 1 In text mode pressing the S3 key will change the displa...

Страница 11: ...be stored when the Popup Window has timed out after 3 seconds if no key has been pressed Graphic User Interface GUI Graphic Icons Graphic ZOOM factors 0 1 0 2 0 3 1 0 2 0 3 0 4 0 5 0 AUTO Battery Stat...

Страница 12: ...12 Average CPM of a specific time frame Maximum CPM since power on...

Страница 13: ...t date and time Press S3 for toggling between date and time Current radiation level reading in CPM Current radiation level in Sv h or mR h format Total count Elapsed time since power on Press S2 for t...

Страница 14: ...ction S3 Sv h mR h CPM selection S4 Menu NOTE Large Font Mode is available in firmware Ver 2 20 or later only Menu Display Main Menu Navigation keys S1 Back S2 Up S3 Down S4 Select Enter User Option N...

Страница 15: ...ode between Year Month Date Hour Minute and Second Each key press will change the mode to be set NOTE Setting of Date and Time is important all history data use Date and Time as a time stamp reference...

Страница 16: ...Threshold saving mode data only will be logged if it exceed the threshold value The data will not be logged while viewing history data in the History Data menu Threshold Data Saving Setting Select th...

Страница 17: ...ery minute H indicates that data has been recorded every hour Searching data in text mode The first symbol indicates this is saved history data to distinguish from real time data display The current h...

Страница 18: ...een to confirm the request After about 3 seconds with Yes confirmation the unit will start to erase entire saved history data It may take a few seconds to complete the task Swivel Display Setting Pres...

Страница 19: ...user can enter up to three calibration points from large to high count rates Procedure 1 Place the testing radiation source 30mm away to the center of unit Geiger Tube side In Text or Graphic mode wai...

Страница 20: ...item and change the popup Windows message to Yes Wait for popup message window s timeout to confirm the reset request Any other key press will cancel the reset request It may take up to 30 seconds to...

Страница 21: ...g the power saving mode Pressing any key will active the LCD backlight again The unit movement does not weak up the unit if the motion detection is OFF Motion Detection GMC 320 has motion detection fe...

Страница 22: ...e real time gyroscope data It displays current unit X Y Z axis data and detected motion event Such as single tap OR double tap Communication Baud Rate This Geiger counter serial communication baud rat...

Страница 23: ...hout a schedule the Timed Count will be started immediately once the timed count period is set The Timed Count can be set from the menu Set a schedule This example shows the schedule is set to 2 minut...

Страница 24: ...starts immediately after the duration set If the Schedule is set then the Timed Count will be started after a scheduled time period passed This is useful if a testing target is not ready immediately O...

Страница 25: ...25 About This menu item is used to gather information about the instruments model number firmware revision and serial number Model information Firmware version Unit serial number...

Страница 26: ...a from GMC 320 Plus Real time monitoring with graphic when it connected with GMC 320 Plus Save the history data in bin OR csv MS Excel format Synchronize the data and time to GMC 320 Plus with compute...

Страница 27: ...SPEAKER1 ALARM0 ALARM1 GETVOLT GETGYRO GETCFG GETCPS GETTEMP HEARTBEAT0 HEARTBEAT1 GETDATETIME CFGUPDATE POWEROFF POWERON SETDATETIME FACTORYRESET For detailed communication protocol commands please...

Страница 28: ...tware automatically submitted data The following tested software are free for automatic submit data feature 1 GQ Geiger Counter Data Logger PRO works on all Geiger Counter 2 GQ Geiger Counter Data Vie...

Страница 29: ...confirm the location If a location change warning received the user need to confirm the location from that Geiger Counter profile OR Create another Geiger Counter from your account In this case you c...

Страница 30: ...Power Saving mode to extend the battery operating time Turn off the speaker if it is not necessary If a fully charged battery run out in less than 5 operating hours then the battery needs to be replac...

Отзывы: