GQ Electronics GMC-320 Plus Скачать руководство пользователя страница 29

 

29 

 
Here: 1. UserAccountID: user account ID. This ID is assigned once a user registration is 
completed. 2. GeigerCounterID: a global unique ID for each registered Geiger Counter. 3. 
CPM: Count Per Minute reading from this Geiger Counter . 4. ACPM: Average Count Per 
Minute reading from this Geiger Counter(optional). 5. uSv: uSv/h reading from this Geiger 
Counter(optional). 
 
Followings are valid data submission examples: 
 
1. http://www.GMCmap.com/log.asp?id=15+13.2+0.075 
2. http://www.GMCmap.com/log.asp?id=15+13.2+0 
3. http://www.GMCmap.com/log.asp?id=15+0+0 
4. http://www.GMCmap.com/log.asp?id=0+13.2+0 
5. http://www.GMCmap.com/log.asp?id=0+0+0.075 
 
The result will be returned immediately. 
 
The following are the returned result examples: 
 
1. OK. 
2. Error! User is not found. 
3. Error! Geiger Counter is not found. 
4. Warning! The Geiger Counter location changed, please confirm the location. 
 
If a location change warning received, the user need to confirm the location from that Geiger 
Counter profile. OR Create another Geiger Counter from your account. In this case, you can 
have two locations share one Geiger Counter. 
 
 

Applications 

 
Stationary Application  

 
The unit has two holes on its back for hanging the unit on the wall for stationary monitoring 
of radiation and long term surveillance applications.  With the wall adapter, it is able to 
monitor the data continuously, 24/7. 
 

 

 
 

Mobile Application 

 

To use the unit in the car while driving, use a car adapter to charge/power the unit. 
Position the unit where it can easily detect radiation, i.e. on the dashboard or similar 
locations in the car. You may need to fix the unit to an appropriate location  for safety 
reasons.   
 
 

Other technical details you may want to know 

 

Data Port 

 

This model has a 3.5mm analog data output port. It uses standard 3.5mm audio stereo plug, 
This port is not for the earphone.  The audio signal is for third party device and software. The 
signal can be connected to other devices or computer microphone port directly.  

 

Содержание GMC-320 Plus

Страница 1: ...GQ GMC 320 Plus Geiger Counter User Guide GQ Electronics LLC Revision 2 13 Sep 2017...

Страница 2: ...GQ Electronics LLC Revised for firmware 3 18 Re 2 00 Jan 2015 GQ Electronics LLC Revised for V4 firmware 4 00 Re 2 10 Jul 2015 GQ Electronics LLC Content revise Re 2 11 May 2016 GQ Electronics LLC Co...

Страница 3: ...t 14 Date and Time setting 15 Data Saving Setting 15 Threshold Data Saving Setting 16 Add Note or Add Location for data saving 16 Note Location Input 16 History data searching 17 History data menu 17...

Страница 4: ...com 28 Software 28 Auto Submit Data Protocol 28 Applications 29 Stationary Application 29 Other technical details you may want to know 29 Data Port 29 USB Port 30 Data collection time 30 Tube recover...

Страница 5: ...5 ACKNOWLEDGEMENTS TO BE FILLED...

Страница 6: ...l time clock on board for time related data logging purposes The USB port communicates with the GQ GMC 320 Plus Soft Geiger Counter software and the GQ Geiger Counter Data Viewer software The GQ GMC 3...

Страница 7: ...or mR h After GMC 320 turned on for one minute it will show the background radiation reading The background radiation reading in CPM indicates the nature radiation detected at that minute This readin...

Страница 8: ...0 second if no key is being pressed during this period 4 Now the unit is ready to use You should see the background CPM rate in absence of a radioactive source Note There is a transparent protective s...

Страница 9: ...ce manger you should see which COM port is assigned to the GMC 320 Plus See the example below Windows assigned COM3 to the GMC 320 Plus unit in this example For the data viewer or the data logger soft...

Страница 10: ...em upwards 4 In the menu mode while a popup message box is opened the S2 key changes the value by cycling through the predefined values S3 key 1 In text mode pressing the S3 key will change the displa...

Страница 11: ...be stored when the Popup Window has timed out after 3 seconds if no key has been pressed Graphic User Interface GUI Graphic Icons Graphic ZOOM factors 0 1 0 2 0 3 1 0 2 0 3 0 4 0 5 0 AUTO Battery Stat...

Страница 12: ...12 Average CPM of a specific time frame Maximum CPM since power on...

Страница 13: ...t date and time Press S3 for toggling between date and time Current radiation level reading in CPM Current radiation level in Sv h or mR h format Total count Elapsed time since power on Press S2 for t...

Страница 14: ...ction S3 Sv h mR h CPM selection S4 Menu NOTE Large Font Mode is available in firmware Ver 2 20 or later only Menu Display Main Menu Navigation keys S1 Back S2 Up S3 Down S4 Select Enter User Option N...

Страница 15: ...ode between Year Month Date Hour Minute and Second Each key press will change the mode to be set NOTE Setting of Date and Time is important all history data use Date and Time as a time stamp reference...

Страница 16: ...Threshold saving mode data only will be logged if it exceed the threshold value The data will not be logged while viewing history data in the History Data menu Threshold Data Saving Setting Select th...

Страница 17: ...ery minute H indicates that data has been recorded every hour Searching data in text mode The first symbol indicates this is saved history data to distinguish from real time data display The current h...

Страница 18: ...een to confirm the request After about 3 seconds with Yes confirmation the unit will start to erase entire saved history data It may take a few seconds to complete the task Swivel Display Setting Pres...

Страница 19: ...user can enter up to three calibration points from large to high count rates Procedure 1 Place the testing radiation source 30mm away to the center of unit Geiger Tube side In Text or Graphic mode wai...

Страница 20: ...item and change the popup Windows message to Yes Wait for popup message window s timeout to confirm the reset request Any other key press will cancel the reset request It may take up to 30 seconds to...

Страница 21: ...g the power saving mode Pressing any key will active the LCD backlight again The unit movement does not weak up the unit if the motion detection is OFF Motion Detection GMC 320 has motion detection fe...

Страница 22: ...e real time gyroscope data It displays current unit X Y Z axis data and detected motion event Such as single tap OR double tap Communication Baud Rate This Geiger counter serial communication baud rat...

Страница 23: ...hout a schedule the Timed Count will be started immediately once the timed count period is set The Timed Count can be set from the menu Set a schedule This example shows the schedule is set to 2 minut...

Страница 24: ...starts immediately after the duration set If the Schedule is set then the Timed Count will be started after a scheduled time period passed This is useful if a testing target is not ready immediately O...

Страница 25: ...25 About This menu item is used to gather information about the instruments model number firmware revision and serial number Model information Firmware version Unit serial number...

Страница 26: ...a from GMC 320 Plus Real time monitoring with graphic when it connected with GMC 320 Plus Save the history data in bin OR csv MS Excel format Synchronize the data and time to GMC 320 Plus with compute...

Страница 27: ...SPEAKER1 ALARM0 ALARM1 GETVOLT GETGYRO GETCFG GETCPS GETTEMP HEARTBEAT0 HEARTBEAT1 GETDATETIME CFGUPDATE POWEROFF POWERON SETDATETIME FACTORYRESET For detailed communication protocol commands please...

Страница 28: ...tware automatically submitted data The following tested software are free for automatic submit data feature 1 GQ Geiger Counter Data Logger PRO works on all Geiger Counter 2 GQ Geiger Counter Data Vie...

Страница 29: ...confirm the location If a location change warning received the user need to confirm the location from that Geiger Counter profile OR Create another Geiger Counter from your account In this case you c...

Страница 30: ...Power Saving mode to extend the battery operating time Turn off the speaker if it is not necessary If a fully charged battery run out in less than 5 operating hours then the battery needs to be replac...

Отзывы: