background image

www.globalplasmasolutions.com

www.gpsair.com

For technical product queries, please reach out to [email protected]

Thank you for purchasing a GPS-FC24-AC air ionization system from GPS Air.

Hardware Provided by GPS

Before you start, confirm the contents of your shipment. Each GPS-FC24-AC will consist of the 

following

1. GPS-FC24-AC with in line power switch.
2. Rare earth magnets (2).
3. Machine screws and nuts (2 each) for mounting magnets. 

Hardware by Others

1. Electrical wiring, junction box, or receptacle to provide power to the GPS-FC24-AC.
2. Self-tapping screws (optional) if not using magnet mount.
3. Zip ties.

As part of the installation process, a Startup Document should be  
completed. For the latest version of the document,  visit our website  
or utilize the QR code.

Installation Location

WARNING:

 MAKE SURE POWER IS DISCONNECTED TO THE HVAC EQUIPMENT BEFORE INSTALLATION

AVERTISSEMENT:

 ASSUREZ-VOUS QUE L’ALIMENTATION EST DÉCONNECTÉE DE L’ÉQUIPEMENT CVC

AVANT L’INSTALLATION

GPS recommends mounting the GPS-FC24-AC after the filtration system and after the coil(s) section(s) in the HVAC 
system. In ductless mini-split ceiling cassette applications, it is suggested to mount the unit to the fan inlet. The 
emitter brushes should be no closer than two inches from any wiring or metal objects.

NOTE: 

Use Temperature - Maximum Ambient temperature in which unit shall be used: 140 degree F/ 60°C

!

!

Содержание GPS-FC24-AC

Страница 1: ...www globalplasmasolutions com Installation Operation Maintenance Manual GPS FC24 AC NOTICE This product is to be used only as directed Read entire manual before use Do not use unless properly installed ...

Страница 2: ...et mount 3 Zip ties As part of the installation process a Startup Document should be completed For the latest version of the document visit our website or utilize the QR code Installation Location WARNING MAKE SURE POWER IS DISCONNECTED TO THE HVAC EQUIPMENT BEFORE INSTALLATION AVERTISSEMENT ASSUREZ VOUS QUE L ALIMENTATION EST DÉCONNECTÉE DE L ÉQUIPEMENT CVC AVANT L INSTALLATION GPS recommends mou...

Страница 3: ... GPS FC24 AC using included hardware See FIGURE 1 4 When mounting in a ceiling cassette use zip ties to secure GPS FC24 AC to fan inlet screen or grid NOTE if mounting in a ceiling cassette that has a self cleaning filter the unit must be mounted behind the screen and self cleaning system but before the fan inlet 5 Install the GPS FC24 AC so that airflow is passing by both emitters at the same tim...

Страница 4: ...ATING SHOCK MAY OCCUR MISE EN GARDE NE JAMAIS TOUCHER AUX BROSSES PENDANT LE FONCTIONNEMENT UN CHOC PEUT SE PRODUIRE Once powered and the inline switch is in the on position the unit initiates an internal check of all systems If the auto cleaning wiper blade is not in the home position it will move to the home position in series with the airflow Cleaning Cycle The GPS FC24 AC comes with a preset c...

Страница 5: ...rify correct height after tightening screw b If the emitter is worn to the point where there is no adjustment replacement emitters can be ordered from GPS Remove the screw and the emitter base unplug the emitter from the connector Plug the new emitter in reinstall base adjust emitter height and tighten screw 4 If unit does not operate properly after verifying the above instructions please contact ...

Страница 6: ...r materials Please visit www gpsair com trademarks for a list of our marks ZERO OZONE EMISSIONS MEASURED OZONE EMISSIONS FROM GPS FC24 AC DURING USE PHASE DOES NOT EXCEED 0 005 PPM AS TESTED BY UL 867 UL COM ECV 3101 Yorkmont Road Suite 400 Charlotte NC 28208 980 279 5622 To access a list of applicable patents please visit www gpspatents com ...

Отзывы: