GPI PA-120H Скачать руководство пользователя страница 1

5252 East 36th Street North
Wichita, KS USA  67220-3205
TEL: 316-686-7361
FAX: 316-686-6746

“ A  G r e a t   P l a i n s   Ve n t u r e s   S u b s i d i a r y ”

www.gpi.net

1-800-835-0113

TABLE  OF  CONTENTS

PA-120H and PA-200H
115-volt Plastic Utility Pump

Owner’s Manual

General Information .............................................................. 1

Installation ............................................................................. 2

Operation .............................................................................. 3

Maintenance ......................................................................... 4

Repair ................................................................................... 6

Troubleshooting .................................................................... 9

Illustrated Parts List ............................................................ 10

Specifications ...................................................................... 11

Service ................................................................................ 11

GENERAL  INFORMATION

Purpose of this Manual

This manual will assist you in operating and maintaining your
pump. It provides information which will help you achieve years
of dependable performance and trouble-free operation.

Using fluids, other than those for which the pump was designed,
could lead to serious personal injury and void the warranty.

Before operating your pump, read this manual thoroughly. If
you have problems with your pump in the future, please refer to
the Maintenance and Troubleshooting Sections.

For assistance, contact your dealer or the GPI Customer
Service Department.

To protect against overload, this pump is equipped with a
thermal protector, which resets automatically, and a circuit

breaker, which resets manually. If your pump stops unexpect-
edly, please reference further information about the thermal
protector and circuit breaker in the Operations or Troubleshoot-
ing Sections.

How to Use this Manual

Specific part names and numbers are given in the Illustrated
Parts List at the end of this manual.

This symbol is used throughout this manual to call
your attention to safety messages.

Warnings alert you to the potential for personal injury.

Cautions call attention to practices or procedures which may
damage your equipment.

Notes  give you information that can improve efficiency of
operations.

It is your responsibility to:

make sure all operators have access to adequate instruc-
tions about safe operating and maintenance procedures.

know and follow all safety precautions specified by your
chemical manufacturer.

know proper safety guidelines for providing electrical power
to your pump.

Read Me!

For your safety, review these warnings and cautions before
operating your pump.

1.

The system is approved for herbicides, pesticides, and
other agricultural chemicals only. Do not use with gaso-
line, diesel, other flammable fluids, or micro-encapsulated
chemicals.

2.

When handling chemicals, always wear protective clothing
such as goggles, gloves, and respirators, as instructed by
the chemical manufacturer.

3.

This pump is designed for use with GFCI protected, 115-
volt power. Do not attempt installation or operation with 12-
volt, 24-volt, or 230-volt power sources. Use only three-
pronged, grounded connectors. Do not use two-prong
adapters. Inspect power cords regularly and replace if
signs of wear are evident.

4.

Serious electrical shock can result from operating electri-
cal equipment on wet ground.

5.

To avoid personal injury, use a ground fault circuit inter-
rupter (GFCI) approved by Underwriters Laboratories Stan-
dard 943 with this pump.

1

Rev. A    921492-2

09/05

Содержание PA-120H

Страница 1: ... List at the end of this manual This symbol is used throughout this manual to call your attention to safety messages Warnings alert you to the potential for personal injury Cautions call attention to practices or procedures which may damage your equipment Notes give you information that can improve efficiency of operations It is your responsibility to make sure all operators have access to adequat...

Страница 2: ...ible Install with 4 inch Inlet 1 Place the Teflon gasket above the EPDM gasket Cen ter both between the bung adapter flange and threads 2 Tighten the bung adapter onto the tank making sure the EPDM gasket stays centered Torque to 50 ft lbs using a bung adapter wrench and a torque wrench 3 Make sure the bung adapter and pump inlet O rings are well seated 4 Place the pump on the bung adapter and pre...

Страница 3: ...d for herbicides pesticides and other agricultural chemicals only Do not use with gasoline diesel other flammable fluids or micro encapsulated chemicals W A R N I N G When handling chemicals always wear protective clothing such as goggles gloves and respirators as instructed by the chemical manufacturer W A R N I N G Figure 4 Make sure hoses are in good condition and connections are tight Make sur...

Страница 4: ...o it rises about 1 2 inch 1cm Figure 6 4 Turn the pump on to recirculate Follow the chemical manufacturer s recommendation for proper recircula tion time When chemical is mixed turn the pump off 5 Before dispensing close the bypass poppet by turning clockwise and pushing in Dispense Chemical The PA 120H pump is intended for use with thin chemicals and the PA 200H for medium thick chemicals only So...

Страница 5: ...erheating and pump damage 7 Drain the hose and nozzle Wipe entire system with a clean wet cloth Clean Pump If chemicals dry inside pump remove the residue before further use 1 Disconnect from power remove the pump from the tank and flush 2 Disassemble the pump as outlined in the Repair Section 3 Thoroughly clean dried chemical from the interior of the pump Take care not to scratch parts NOTE Do no...

Страница 6: ... on the tank 3 Complete the steps given in Before Each Use proce dures 6 Figure 12 Figure 13 During repair carefully inspect all parts for wear or damage and replace as necessary Check O rings and seals for breakage wear and signs of deterioration such as swelling Before installing coat O rings seals and drive components with high temperature lithium grease Clean or Replace Strainer 1 Disconnect p...

Страница 7: ... to 45 to 50 in lbs Convert an Inlet Fitting Inlet fittings may be converted from one size to another by using the replacement instructions above Simply remove one inlet and install another Clean or Replace Bypass Poppet 1 Disconnect pump from power and flush 2 Remove the bypass poppet plug Figure 17 3 Remove the bypass poppet Gently rock it back and forth as necessary to remove 4 Wipe the cavity ...

Страница 8: ...rive shaft with the motor adapter or the planetary gear module When properly aligned the drive shaft will slip into place with the motor against the housing 4 During assembly make sure the motor is properly seated against the motor adapter seal and the housing 5 Replace the screws fastening the motor and handle to the housing Use the two longer screws to secure the handle Torque to 75 to 100 in lb...

Страница 9: ...or Remove and inspect drive shaft Replace if necessary 9 4 inch bung adapter spring Remove pump and bung adapter Clean spring and install again clogged 10 Gear wear Remove the coverplate and inspect wearplates as appropriate gears and drive key Gears must turn freely with the drive key removed Replace any worn or damaged parts C LOW FLOW RATE 1 Low voltage Check for adequate power supply voltage 2...

Страница 10: ...dule PA 200H 1 904003 50 Sems Screw 8 32 x 11 16 in PA 200H not shown 4 118016 1 Shaft Adapter PA 120H not shown 1 6 118505 1 Drive Shaft Kit 1 6A 901001 91 Motor Adapter Seal or Kit 1 6B 904003 70 Motor Shaft Washer or Kit 1 6C 110078 8 Motor Shaft Seal or Kit 1 6D 118020 1 Bearing or Kit 2 11 118006 1 Pump Housing 1 13A 118508 1 Bypass Poppet Assembly Kit 4 inch 1 13B 118508 2 Bypass Poppet Asse...

Страница 11: ...0 minutes ON 30 minutes OFF Duty cycle will vary with viscosity and temperature Electrical Specifications Input 115 volt AC grounded GFCI protected Cord 18 gauge 3 wire grounded plug equipped with circuit breaker Mechanical Connections Bung 2 or 4 inch Nipple 2 inch Inlet 1 inch Outlet 1 inch Recommended Accessories Standard EPDM 1 in x 12 ft 3 7m discharge hose Standard 1 in ball valve nozzle SER...

Страница 12: ...warranty shall not apply if A the product has been altered or modified outside the warrantor s duly appointed representative B the product has been subjected to neglect misuse abuse or damage or has been installed or operated other than in accordance with the manufacturer s operating instructions To make a claim against this warranty contact the GPI Customer Service Department at 316 686 7361 or 1...

Отзывы: