![GPI M-1115S-AU Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/gpi/m-1115s-au/m-1115s-au_product-owners-manual_2248788016.webp)
MAINTENANCE
NOTE: This pump is designed for minimum maintenance. The motor
bearings are sealed and require no lubrication. Inspect the pump and
components regularly for fuel leaks and make sure the hose and power
cord are in good condition. Keep the pump exterior clean to help
identify leaks.
IMPORTANT:
Do not use this pump for water, chemicals or herbicides.
Dispensing any fluid other than those listed in this manual will damage the
pump. Use of the pump with unauthorized fluids will void the warranty.
Clean or Replace Strainer
1. Turn the pump off and disconnect from power. Remove the strainer
coverplate, making sure not to damage the O-ring (see Figure 14).
Remove the inlet strainer and inspect for damage or clogs (see
Figure 12). Clean the strainer with a soft-bristled brush and solvent
(see Figure 13). If the strainer is very dirty, compressed air may be
used. If damaged, replace the strainer.
2. Place the strainer in the cavity. Clean the coverplate and O-ring. Coat
the O-ring lightly with grease. Ensure the coverplate O-ring is properly
seated (see Figure 14) and tighten the strainer coverplate.