OPERATION
IMPORTANT:
Always follow safety precautions when operating this
equipment. Review the Safety Instructions.
To prevent physical injury or property damage,
observe precautions against fire or explosion
when dispensing fuel. Do not operate the system in the presence
of any source of ignition including running or hot engines, lighted
tobacco products, gas or electric heaters, or any type of electronic
device. A spark can ignite fuel vapors.
Before each use, repair leaks around seals or
connections. Make sure hoses are in good
condition and connections are tight.
NOTE: Make sure the work area is dry.
Make sure the pump is properly grounded. Repair
any corroded or damaged wiring before use.
NOTE: Ensure the tank contains enough fuel.
IMPORTANT:
Make sure the fuel is not contaminated with debris.
Tighten loose tank lids regularly.
Dispensing Fuel
1. Turn on the pump by removing the nozzle from the holder and pushing
up the switch lever. Insert the nozzle into the receiving tank and
squeeze the handle to start fuel flow. When done, release the nozzle
handle, turn the pump off and return the nozzle to its holder.
IMPORTANT:
This pump is designed to be self-priming. If fuel is not
delivered within 15 to 20 seconds, turn the pump off and refer to priming
information in the Troubleshooting Section.
An automatic bypass valve prevents pressure build
up when the pump is on with the nozzle closed. To
avoid pump damage, do not run the pump more than 10 minutes with
the nozzle closed.
Never leave the pump running without fluid. Dry
running can damage the pump components, and
will void the warranty.
IMPORTANT:
This is an intermittent duty pump, after running the pump
for a maximum of 30 minutes, allow it to cool for 30 minutes.
Thermal Motor Protector
IMPORTANT:
The motor is provided with an internal auxiliary
temperature-limiting device. Excessive motor heat can trip the device.
It resets automatically after the motor has cooled.
1. If the auxiliary temperature limiting device trips, reset by turning the
switch OFF. Let the pump cool then turn ON again. If the device
trips again, see the Troubleshooting Section of this manual.
Always turn the pump off if the temperature-
limiting device trips. If left on, the pump will
automatically reset when cool and start pumping.
Never leave pump running unattended.