50.04.504 / 1.0
Copyright by GOVI GmbH 2021. The reproduction of this document or any part thereof is prohibited. We reserve the right to make technical changes during the course of further developments.
OPERATION MANUAL - Trailer Refrigeration Unit
arktik 1600N • 1600 N/T • 2000N • 2500N • 2000P • 2500 N/K • 2000 P/K
29
Page
10.2.2 Cleaning Parts Outside the Refrigeration Unit
1.
Disconnect the trailer refrigeration unit from the power supply by
pulling the main plug.
2.
Loosen and remove the five screws on the upper side of the trailer
refrigeration unit and take off the main cover (1).
3.
Clean the condenser (2) by blowing compressed air from top to
bottom through the cooling fins from an appropriate distance.
If necessary, align fins after the cleaning procedure.
4.
Fasten the main cover (1) using the screws.
5.
Connect again the trailer refrigeration unit to the power supply by
inserting the main plug.
Fig. 10-2 Cleaning parts outside
the refrigeration unit
1. Main cover
2. Condenser
1