5.2.2.4
(S)erial Output
Alterations within this menu become effective by resetting the system (turn the antenna
off and then on). Depending upon the alterations made, it may be necessary to use a
different baud rate/ text document to call up the monitor (section 5.2.1 on page 27).
Figure 18
Menu: (S)erial Output
Input of
enables switching between 9600 and 19200 Baud. Via
it is possible to
select, whether the highest byte is to be output first or last. When connecting this
equipment with a Siemens PLC, this parameter has to be 0 (
High Byte first
).
With
you choose the desired procedure — 3964R, transparent or Monitor only. In
case Monitor only is chosen you can set the baud rate and procedure. This is useful
whenever the serial output is only used for parametrizing and CAN or Profibus are
used for data output. For the procedure 3964R you have to set the
cknowledgement
delay time.
influences the composition of the output telegram.
Based on the values given in Table 5 „Data words in a telegramm of 21 byte length“
on page 17, you can define the desired elements of your telegram
by hexadecimal
addition. The sequence of the parameters cannot be influenced. It will always comply
with the sequence in the table!
Example
You only want to display the code.
Add up the values 0000.0004 for the upper 16 bits and
0x0000.0008 for the lower code bits as well as the 0x0000.0001
for STX. Therefore input D.
Using „(
)isplay Telegram Content“ it is possible to check the generated telegram
(refer Figure 19). In this example the mask has the value 0x0000 and the telegram
length is 14. Press any key to return to the menu
Serial Output
.
S:0021 X:+0004 Code: 00000000 Read: 0:
Frx[/Hz]:66920 Ftx[/Hz]:127950
U[/mV]:24200 I[/mA]: 240 T[Grd.C]:+28 E: 0000 N: 0
(B)audrate: 9600
(P)rocedure 3964R
(O)rder of Data Transfer (0= HiByte first): 0
(T)elegram Content Mask [0..1FFF]: 1fff
(D)isplay Telegram Content
(C)har-Delaytime [1..220ms]: 220
(A)ck-Delaytime (3964R) [1.1680ms]: 1680
Co(n)tinous Telegrams 1
(S)erial Data Period [1..1000ms]: 8
(Q)uit Menue