Device Description HG G-7335xZB | English, Revision 06 | Date: 30.04.2020
21
Software – Chapter 7
Figure 4
Screenshot: Main menu of the monitor program (HG G-73350 with CAN Bus)
Figure 5
Screenshot: Main menu of the monitor program (HG G-73351 with Profibus)
The first two lines represent the input.
S1, S2, D1, D2
The values for
S1
,
D1
,
S2
, and
D2
are each the sum of the 16 samplings. The range
for the sum voltage is 0 to 16383 and for the difference voltage -8192 to +8191.
X1, X2
X1 and X2 present the calculated values for the collateral deviation of the antennas
above the guide wire in a range from -255 to +255 in mm. The value of the threshold
will be -256 if the corresponding voltages of S1 respectively S2 fall below the set
threshold.
Status
The hexadecimal output of binary coded system statuses in the same format as out
-
put via the serial telegram, PDO_1 (CAN) or Profibus.
S1: 1 D1: -10 S2: 10816 D2: -4403 X1:-256 mm X2: -50 mm Status: 0x40
(1) Select Antenna System 1
(2) Select Antenna System 2
(C)AN Menue
(L)oad Values to EEProm
(O)utput CSV-Data (press 'a' to abort)
(U)pdate Firmware
(S)ervicemenue
(Q)uit
Software Version 73350A01.05 / 15.MAR.2005 Serial Number: 9999999
S1: 6418 D1: 65 S2: 0 D2: -16 X1: +0 X2: -256 Status: 0x80
(1) Select Antenna System 1
(2) Select Antenna System 2
(P)rofibus Menu
(L)oad Values to EEProm
(O)utput CSV-Data (press 'a' to abort)
(U)pdate Firmware
(S)ervicemenue
(Q)uit
Software Version 73351A01.00 / 03.SEP.2008 Serial Number: 7385277