![Gotting HG G-193 0-B Series Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/gotting/hg-g-193-0-b-series/hg-g-193-0-b-series_manual_2247524024.webp)
Device Description HG G-193x0-B | English, Revision 02 | Date: 07.05.2018
24
Chapter 6 – Configuration
6.4.6 HG G-193x0ZB: (5) CAN Config
Configuration of NodeID and Baudrate. The sub menu CAN-Status lists the reception and
transmission counters as well as possible errors. Additionally CAN statistics are shown (RX
packet counter, TX packet counter, error counter).
Figure 16
Menu CAN config
6.4.7 Firmware Update
If necessary this menu can be used to update the firmware of the inductive guidance sensor
to a new version. In order to update the firmware the device has to be put into DFU (Device
Firmware Upgrade) mode.
Figure 17
Firmware Update Menu
After pressing
the connection in the terminal program should be closed until the update
in DFU mode is finished.
You need the
.dfu
firmware file and the software
DfuSe
by ST Microelectronics®. You can
request
.dfu
firmware files from Götting and they will be sent to you via e-mail. You can
download the DfuSe software from the following address:
Link
http://www.st.com/en/development-tools/stsw-stm32080.html
HG 193x0 ZB V1.01 CAN config Goetting KG
NodeID: 1
Baudrate: 250 kBit/s
1: Edit Node ID
2: Edit Baudrate
3: CAN Status
Press any other key to quit
Press y to reboot the device in DFU mode
Press any other key to quit