Software
Englisch, Revision 14, Date: 07.02.2017
31
5.2.2.1
Main menu
Figure 13
Main menu of the monitor program
Each of the screen menus contains important system variables in the first three lines
(refer also to Table 20), as they also appear in the output telegram (described in sec-
tion 4.2.6.1.1 on page 19). The last line on the screen contains possible status mes-
sages, if e. g. predetermined value ranges have not been observed during input.
Description of the system variables
S
Measured voltage of the sum coil within the cover of the casing
in samples (max. 1023).
X
Measured voltage of the difference coil within the cover of the
casing in samples (max. 1023).
Code
The 32 bits of the decoded transponder code.
Read
Number of readings per transponder crossing. This value is pre-
served until another transponder is detected. It is also deleted
through Noise.
U [mV]
Supply voltage of the processor circuit board, measured exactly
to 100 mV. Due to various protective measures, it is always
slightly lower than the applied supply voltage.
I [mA]
Current consumed by the positioning unit, measured to 10 mA
accurately.
T [Grd.C]
Approximate temperature inside the unit, measured in 5
o
C
steps. The sensor is located near a cooling sheet.
Table 20
Description of the system variables (monitor program) (Abschnitt 1 von 2)
S:0568 X:+0000 Code: 00000000 Read: 0
U[/mV]:24000 I[/mA]: 150 T[Grd.C]:+28 E: 0200 N: 0
Ftx[/Hz]:105960 Prog_Code: 00000000
(W)rite Transponder Code
(T)ime & Code
(S)erial Output
C(A)N-Parameters
P(r)ofibus-Parameters
(P)assword
(L)oad Values to EEProm
(E)rror ?
Cs(v) (38,4 KB Code(5d),Sum(4d),Tr(1),Co(1),+-(1),Po(1),Cnt(1d)<crlf>)
(B)oot Load
Serv(i)ce Menu
(Q)uit Monitor
Software Version 98780A11.00 / 31.OCT.2005 Serial Number: 9999999