We advise the use of this contact to cut off refrigeration in the event of an
overflow in the detection unit.
Ensure that the electrical connections to the pump are sealed fully
using the insulating cap, which must be secured with a cable tie.
Hydraulic connection :
Hydraulic connection :
Hydraulic connection :
Hydraulic connection :
On mini-split, wall mounted equipment, the detection unit is connected to the
end of evacuation pipe by means of a rubber sleeve (supplied). On other types,
the rubber sleeve is connected to the drain tank outlet. The length of this sleeve
can be adjusted. The detection unit must be installed horizontally, in the
location reserved inside the foam elbow (tolerance 15°).To avoid dysfunction of
the magnet, this unit must not be fixed on a metallic brace. Install the
ventilation tube on the detection block.
Assembly on the left
The hydraulic discharge connection uses flexible piping having an inside Ø6 mm.
The
RAPIDO
must not be immersed or placed outside of the premises or in a
damp place, or in temperature below 0°C.
Tubing
Detection unit
Ventilation
tubing