The operating temperature is listed in the following table.
Table 4-1 Operating Temperature
Parameter
Min
Typ.
Max
Unit
Normal Temperature
-30
25
75
℃
Storage Temperature
-40
85
℃
Extreme Operating Temperature
-40°C~ -30°C
/
+75°C~ +85°C
℃
4.2.
C
URRENT
C
ONSUMPTION
The values of current consumption in different operating mode are shown below.
Table 4-2 Average current consumption
Parameter
Condition
Typical Value
Unit
Power-off
Shutdown leakage current
2.5
μ
A
PSM mode
Power Save Mode
4
μ
A
eDRX mode
Base current
45
μ
A
PTW=5.12S, eDRX cycle 20.48S,DRX
cycle 2.56S
125
μ
A
IDLE
Idle mode
292
μ
A
Working
current
in
NB-IoT
LTE FDD Band 1, Pout=23dBm
92
mA
LTE FDD Band 3, Pout=23dBm
99
mA
LTE FDD Band 5, Pout=23dBm
105
mA
LTE FDD Band 8 ,Pout=23dBm
105
mA
LTE FDD Band 20 ,Pout=23dBm
107
mA
LTE FDD Band 28 ,Pout=23dBm
125
mA
4.3.
RF
O
UTPUT POWER
Table 4-3 RF Output power
mode
Frequency
Limit
Test(Unit:dbm)
NB-IoT
LTE FDD Band 1
23 ±2.7dBm
23.3
LTE FDD Band 3
23 ±2.7dBm
23.5
LTE FDD Band 5
23 ±2.7dBm
22.8
LTE FDD Band 8
23 ±2.7dBm
23.3
LTE FDD Band 20
23 ±2.7dBm
23.3
LTE FDD Band 28
23 ±2.7dBm
23.3