background image

Operating Instructions 

 

PROFITEST H+E TECH

 

Page 

9

   

 

Initial Start-Up 
 
General

 

 
 

Warning!

 

 
 

Danger!

 

The device should be checked to assure that it’s in good condition before initial start-up. 
The device may only be used by trained personnel. 
 

Inserting the Batteries

 

The device can be operated with two rechargeable or regular 9 V block batteries. The two battery 
compartments (3) on the right side of the device are opened in order to insert the batteries.

 

Battery polarity is identified in the battery compartment. 
 

 

Warning!

 

It is absolutely essential to assure that battery polarity is not reversed. 
 
The battery compartments are closed after the batteries have been inserted. 
Only high quality regular or rechargeable batteries should be used! 
 

Connecting the Power Pack

 

A 12 V power pack is included in scope of delivery of the inline tester. The device can be operated 
with either batteries or the power pack. 
The power pack is connected by inserting its plug into the socket (2) at the right side of the device. 
The batteries are disconnected from supply power when the power pack is connected.

 

 

Warning!

 

Use only the included power pack in order to avoid damage to the inline tester!

 

 
Switching the Inline Tester On

 

The on button (4) is pressed and held for about 4 seconds in order to switch the inline tester on. A 
start-up message appears. As soon as the start-up message is replaced with the normal display 
(see page 5), the on button (4) can be released. 
 

Switching the Inline Tester Off

 

Briefly press the off button (3) in order to switch the device off. 
The device is switched off after about 10 minutes if neither of the rotary switches (1 and 2) has 
been activated during this time. Display illumination is switched off after just 30 seconds. 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание M525B

Страница 1: ...structions PROFITEST H E TECH Diagnostics Unit for Electric Charging Stations Type 2 Connector Socket and Plug 3 349 878 03 1 3 16 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ...eneral Notes These operating instructions include important information about your device s features and its use Before using the device read the instructions carefully and familiarize yourself with its operation Keep these operating instruction in a safe place Explanation of Symbols This product fulfills guidelines in accordance with 89 336 EEC Warning regarding property damage Safety precautions...

Страница 3: ... mode 3 charging Use for other purposes is prohibited Target Group Only trained qualified electricians may use the PROFITEST H E TECH inline tester Trained qualified electricians fulfill the following requirements Knowledge of general and specific accident prevention regulations Knowledge of applicable electrotechnical regulations Training in use and care of appropriate safety equipment Ability to...

Страница 4: ... Key 1 Protective cover 2 Power pack connector socket 12 V 1A 3 Battery compartment for two 9 V block batteries 4 Control panel 5 Carrying handle 6 Cable outlet with type 2 charging socket for connection to the vehicle 7 Cable outlet with type 2 charging plug for connection to the charging point 2 1 3 4 5 6 7 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 5: ...ctor switch and OK button 2 Rotary status selector switch and escape button 3 Off button 4 On button the button has to be pressed and held for several seconds in order to switch the unit on 5 Display 6 USB port www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 6: ...s PROFITEST H E TECH Page 5 Display Layout The display is subdivided into various blocks 1 Vehicle States 2 Cable Conditions 3 Error States www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 7: ...Operating Instructions PROFITEST H E TECH Page 6 4 PWM Signal Evaluation 5 Phases and Phase Sequence 6 Battery Level www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 8: ...appear at the display Vehicle States No vehicle connected Vehicle connected Vehicle not ready Vehicle ready to charge No ventilation required Ventilation required Cable Condition No cable 13 A cable 20 A cable 32 A cable 63 A cable www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 9: ...Phase Sequence Phase L1 switched on Phase L2 switched on Phase L3 switched on Clockwise phase sequence Counterclockwise phase sequence Battery Level Battery full Battery depleted www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 10: ...ivery of the inline tester The device can be operated with either batteries or the power pack The power pack is connected by inserting its plug into the socket 2 at the right side of the device The batteries are disconnected from supply power when the power pack is connected Warning Use only the included power pack in order to avoid damage to the inline tester Switching the Inline Tester On The on...

Страница 11: ...ter in combination with an electric vehicle The device makes the following functions available Display of the Vehicle State CP States A B C and D can be displayed in accordance with IEC 61851 Symbols corresponding to the various vehicle states appear at the display see pages 6 and 8 Display Status Voltage U L Meaning A 12 V 12 V No vehicle B 9 V 12 V Vehicle connected C 6 V 12 V Ready without vent...

Страница 12: ...tive voltage but with the opposite preceding sign PWM frequency The valid PWM frequency should be 1000 Hz Charging current Displayed charging current is calculated from the duty cycle see explanation under duty cycle Duty cycle In accordance with IEC 61851 the charging point communicates the maximum permissible charging current to the vehicle via the duty cycle Charging current is calculated autom...

Страница 13: ...s no longer possible Battery full is indicated when the power pack is connected USB Port The USB port is used to install firmware updates and depending on software version to transmit diagnostics results to a connected PC Warning Danger The USB port may not be connected to a PC or a notebook while a charging point is being diagnosed Language Selection Upon shipment from the factory the user interf...

Страница 14: ... the user If repairs should become necessary please contact our repair and replacement parts service department see address on back cover Outside surfaces may only be cleaned with a dry lint free cloth Danger No liquids may be permitted to penetrate into the device s interior or the plug connectors Technical Data Input voltage 400 V 3 phase Frequency 50 Hz Test consumer power Max 2 9 kVA Electrica...

Страница 15: ... phase 70 A 1 phase 100 0 5 W 1 2 75 150 Interrupt power supply 75 1 The power dissipation of the resistor caused by the detection circuit shall not exceed the value given above The value of the pull up resistor shall be chosen accordingly 2 Upon open circuit failure mode resistors used should preferably fail such that the resistance value rises Metal film resistors commonly show acceptable proper...

Страница 16: ...not requiring ventilation R3 1 300 1261 1339 Switched resistor value for vehicles requiring ventilation R3 270 261 9 278 1 Equivalent total resistor value no ventilation Figure A 2 Re 882 856 908 Equivalent total resistor ventilation required Figure A 2 Re 246 239 253 Diode voltage drop 2 75 10 mA 40 C to 85 C Vd 0 7 0 55 0 85 V Maximum total equivalent input capacity Cv 2 400 N A pF Value ranges ...

Страница 17: ...t ready off 0 V Steady voltage Vb 0 EVSE or utility problem or utility power not available or pilot short to earth F yes N A no not ready off N A 12 V Steady voltage EVSE not available a All voltages are measured after stabilization period b The EVSE generator may apply a steady state DC voltage or a 12 V square wave during this period The duty cycle indicates the available current as in Table A 5...

Страница 18: ...es D1 D2 positive 2 59 3 3 28 2 3 4 State E 0 0 1 1 0 1 States A2 B2 C2 D2 negative State F a 12 6 12 11 4 13 12 11 a Applicable to Va only Note the EVSE may also be designed to use the voltage of the internal generator Vg as a reference The valid voltage ranges are then to be calculated as given in the following table These ranges are identical to the values in the above table for Vg 12 V Source ...

Страница 19: ... duty cycle 96 available current duty cycle 64 x 2 5 A 96 duty cycle 97 80 A duty cycle 97 Charging not allowed If the PWM signal is between 8 and 97 the maximum current may not exceed the values indicated by the PVM even if the digital signal indicates a higher current In 3 phase systems the duty cycle value indicates the current limit per each phase The current indicated by the PWM signal shall ...

Страница 20: ...and it only functions when a vehicle is detected The diagnostics unit is capable of simulating a vehicle Diagnosis The evaluation of the PWM signal the cable coding for the phases turn off times and the direction of phase rotation are significant with regard to diagnosis The diagnostics unit displays this information www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply c...

Страница 21: ...d forth between states Check parameters and turn off times Switch back and forth between cables Check parameters Trigger errors Check system performance Error diagnosis Error L1 L2 L3 not connected in correct phase sequence www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 22: ... TECH Page 21 Error diagnosis Error L2 not connected or fuse L2 blown Error diagnosis Error No PWM signal Signal generation or cable connection defective www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 23: ...values for duty cycle and charging current Cable detection defective Error diagnosis Error Erroneous values for PWM voltage and frequency Signal generation defective or CP and PP connections reversed www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...