Specifications Information and Repair Parts Manual  

    

573X Series

                                                           

5730-250-00

2

1/2020

ORIENTING PUMP

1.  The pump can be oriented in any desired position: discharge up or down, 

left or right.

2.  If motor is oriented vertically up, a means of venting air from the seal 

chamber must be installed in the seal plate (Ref. No. 8) 1/8” NPT port. 
Remove 1/8” NPT plug (Ref. No. 6) and install air venting device or liquid 
injection line.

3.  DO NOT INSTALL UNIT with motor vertically down, any liquid breaching 

the mechanical shaft seal will run directly down shaft into motor. 

NOTE: 

Proper motor support is required to avoid damage to pump or motor. 

Use correct size motor hanger similar to the one pictured based on model 
being installed. Hangers vary depending on horizontal or vertical installation 

(see figure 1). 

INSTALLING FLANGES

1. 

Included with pump: (2) 3” NPT flanges, 2 gaskets, and 4 bolts, nuts, and 

washers.

2. 

Install flanges on piping using sealing tape or pipe sealant.

3. 

Insert gasket into machined groove on pump flange.

4. 

Position pump by lining up bolt holes on pump flange with bolt holes on 
pipe flange.

5.  Install 4 hex head bolts, nuts, and washers with thread sealant (Vibra-Tite 

(12150) Threadlocker Medium Strength Removable).

6. 

Torque both flange bolts in even increments to a value of 8-11 ft-lbs (1.1-
1.5 Kg-m). Torque the bolts in both the suction and discharge flanges in 

this manner.

OPERATION

1. 

Prior to pump start up, be sure system is clean and filled with clean liquid 

that is compatible with pump components.

2. 

Pressure the pump body slowly. Check for leaks at the flange joint, the 

pump casing and motor shaft.

 

Pressurize  pump  casing  slowly.  Failure  to  check  for  leaks  at  all  joints 
sealed with a gasket may result in personal injury or property damage. 
Installation of a collection pan and/or drain is required to prevent property 
damage from system leaks.

3.  DO NOT RUN PUMP DRY!

 Mechanical shaft seal damage will occur 

if pump is run dry. Pump body must be filled with liquid before starting 

motor. Air must be vented from the system by means of an air vent located 
at a high point in the system. 

MAINTENANCE

 

 

Make certain that the unit is disconnected and locked out from the power 
source before attempting to service or remove any components. 

1. 

System  must  be  drained  or  pump  isolated  by  turning  off  suction  and 

discharge valves before attempting to remove pump.

Patterson/AMT Inline Circulator Pumps

 

 

Water temperature in system cannot exceed 90̊ F (32̊ C) before removing 
or  servicing  pump.  If  draining  system,  leave  drain  valve  open  during 
servicing.

 

Pump surface temperature cannot exceed 90̊ F (32̊ C) before removing or 
servicing pump.

 

 

Loosen flange bolts slightly and shift pump side to side to vent internal 
pump casing pressure before removing or servicing pump.

2. 

Remove pump from the system by removing eight flange mounting bolts, 

nuts and washers (Ref. Nos. 18 & 19).

SHAFT SEAL REPLACEMENT

Refer to Figure No. 2 for part identification. Order Ref. No. 13A to replace all 

seals and o-rings.

REMOVAL OF OLD SEAL

IMPORTANT: 

Always replace both seal seat (Ref. No. 10) and seal head 

(Ref. No. 11) to ensure proper mating of components. Also, impeller seal (Ref. 
No. 13) should be replaced anytime impeller fastener (Ref. No. 14) has been 
removed.
1.  Remove fasteners (Ref. No. 5) connecting casing (Ref. No. 15) to adapter 

(Ref. No. 7).

2. 

Slide  casing  off  of  adapter  locating  boss.  Take  care  when  removing 

casing, it may be heavy.

  

Care should be taken not to pinch or “shave” casing o-ring (Ref. No. 9) 
between seal plate (Ref. No. 8) and casing.

3.  Use a box wrench and/or socket wrench to remove impeller fastener. 

Remove impeller seal and impeller (Ref. No. 12).

NOTE:

 Stub shaft must be held in place to remove impeller. Insert a hex key 

through adapter opening into one of the screws fastening shaft clamp (Ref. No. 
2) to motor/stub shaft. Brace hex key against side of adapter opening. Impeller 
and impeller fastener unscrew CCW when looking at the impeller eye. 
4.  Disconnect any piping or venting apparatus attached to seal plate 1/8” 

NPT wash/vent port.

5.  The seal head can now be pulled from shaft. Remove seal plate (Ref. No. 

8) from adapter.

6.  Pry seal seat from cavity in seal plate.

Содержание Patterson/AMT 573 Series

Страница 1: ...ump will not self prime 2 Piping system must be designed for adequate thermal expansion 3 A pressure relief valve should be considered to protect pump casing from over pressurization and pressure spik...

Страница 2: ...th liquid before starting motor Air must be vented from the system by means of an air vent located at a high point in the system MAINTENANCE Make certain that the unit is disconnected and locked out f...

Страница 3: ...Remove fasteners Ref No 5 connecting adapter Ref No 7 to motor Ref No 1 3 Remove adapter from motor 4 Loosen fasteners of shaft clamp Ref No 2 Remove shaft clamp stub shaft Ref No 4 and drive key Ref...

Страница 4: ...250 00 4 1 2020 For Repair Parts contact dealer where pump was purchased Please provide following information Model Number Serial Number if any Part description and number as shown in parts list Patt...

Страница 5: ...Incl w Ref KIT 1643 411 00 Incl w Ref KIT 1643 411 00 Incl w Ref KIT 1643 411 00 Incl w Ref KIT 1 12 Impeller Kit 5735 010 97 5735 010 97 5735 010 97 5735 010 97 1 includes Ref Nos 12 and 14 13 Impell...

Страница 6: ...Specifications Information and Repair Parts Manual 573X Series 5730 250 00 6 1 2020 NOTES...

Страница 7: ...Specifications Information and Repair Parts Manual 573X Series 5730 250 00 7 1 2020...

Страница 8: ...Specifications Information and Repair Parts Manual 573X Series 5730 250 00 8 1 2020 www amtpump com...

Отзывы: