background image

OM−00856

80 SERIES

MAINTENANCE & REPAIR

PAGE E − 7

oil and the container must be 

absolutely

 clean. If

the oil has been previously used, it must be 

thor-

oughly

 filtered.

Heat the bearings to a uniform temperature 

no

higher than

 250

_

F (120

_

C), and slide the bearings

onto the shaft, one at a time, until they are fully
seated against the shaft shoulders. This should be
done quickly, in one continuous motion, to prevent
the bearings from cooling and sticking on the shaft.

Use caution when handling hot bear-
ings to prevent burns.

After the bearings have been installed and allowed
to cool, check to ensure that they have not moved
out of position in shrinking. If movement has oc-
curred, use a suitably sized sleeve and a press to
reposition the bearings.

If heating the bearings is not practical, use a suit-
ably sized sleeve and an arbor (or hydraulic) press
to install the bearings on the shaft.

When installing the bearings onto the
shaft, 

never

 press or hit against the outer

race, balls, or ball cage. Press 

only

 on the

inner race.

Slide the shaft and assembled bearings into the
pedestal until the inboard bearing is fully seated
against the bore shoulder.

When installing the shaft and bearings into
the bearing bore, push against the outer
race. 

Never

 hit the balls or ball cage.

Position the oil seal (12) in the pedestal bore with
the lip positioned as shown in Figure 1. Press the
oil seal into the bore until fully seated.

Position the oil seal (20) in the bearing retainer (19)
with the lip positioned as shown in Figure 1. Press
the oil seal into the retainer until fully seated.

Replace the bearing retainer O-ring (24) in the ped-
estal, and lubricate it with grease. Press the bear-
ing retainer into the pedestal until it seats against
the bearing. Be careful not to cut the oil seal lip on
the shaft keyway. 

Be sure

 the setscrews (22) in the

bearing retainer are positioned horizontally inline.

Install the same thickness of bearing adjusting
shims (17) as previously removed. Reinstall the re-
taining ring (18) and check shaft endplay.

NOTE

Shaft endplay should be .002 to .005 inch (0,05 to
0,12 mm). Add or remove bearing adjusting shims
to obtain this endplay.

Install the slinger ring (27) and shaft key (20). Install
any leveling shims used under the pedestal feet.

Seal Reassembly and Installation

(Figures 1 and 3)

Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent.

Most cleaning solvents are toxic and
flammable. Use them only in a well-ven-
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain-
ers.

The seal is not normally reused because wear pat-
terns on the finished faces cannot be realigned
during reassembly. This could result in premature
failure. If necessary to reuse an old seal in an emer-
gency, 

carefully

 wash all metallic parts in fresh

cleaning solvent and allow to dry thoroughly.

Handle the seal parts with extreme care to prevent
damage. Be careful not to contaminate precision
finished faces; even fingerprints on the faces can
shorten seal life. If necessary, clean the faces with a

Содержание 80 SERIES

Страница 1: ...MAN RUPP COMPANY D MANSFIELD OHIO www grpumps com GORMAN RUPP OF CANADA LIMITED D ST THOMAS ONTARIO CANADA Printed in U S A eCopyright by the Gorman Rupp Company INSTALLATION OPERATION AND MAINTENANCE...

Страница 2: ...rial number and e mail address required RECORD YOUR PUMP MODEL AND SERIAL NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this in...

Страница 3: ...ps PAGE B 3 Suction Line Positioning PAGE B 3 DISCHARGE LINES PAGE B 4 Siphoning PAGE B 4 Valves PAGE B 4 Bypass Lines PAGE B 4 ALIGNMENT PAGE B 5 Coupled Drives PAGE B 5 V Belt Drives PAGE B 5 V BELT...

Страница 4: ...moval PAGE E 4 Impeller Removal PAGE E 4 Seal Removal and Disassembly PAGE E 5 Shaft And Bearing Removal And Disassembly PAGE E 5 Shaft And Bearing Reassembly And Installation PAGE E 6 Seal Reassembly...

Страница 5: ...on Pumps and related equipment must be installed and operated ac cording to all national local and industry stan dards If there are any questions regarding the pump or its application which are not co...

Страница 6: ...es 6 Vent the pump slowly and cau tiously 7 Drain the pump This pump is designed to handle most non volatile non flammable liquids containing specified entrained solids Do not attempt to pump liquids...

Страница 7: ...sly 6 Refer to instructions in this manual before restarting the pump Do not remove plates covers gauges pipe plugs or fittings from an over heated pump Vapor pressure within the pump can cause parts...

Страница 8: ...ped with a Gorman Rupp double grease lubricated seal therefore the maximum incoming pressure must be limited to 10 p s i For further assistance contact your Gorman Rupp distributor or the Gorman Rupp...

Страница 9: ...emove all customer installed equipment such as suction and discharge hoses or piping before attempting to lift existing installed units The pump assembly can be seriously damaged if the cables or chai...

Страница 10: ...the pump user make certain that the total area of the openings in the strainer is at least three or four times the cross section of the suction line and that the openings will not permit passage of s...

Страница 11: ...ge line use a valve as large as the largest pipe to minimize friction losses Never install a throttling valve in a suction line With high discharge heads it is recommended that a throttling valve and...

Страница 12: ...in both the horizontal and vertical planes Most couplings require a specific gap or clearance between the driving and the driven shafts Refer to the coupling manufacturer s service literature Align s...

Страница 13: ...ion v belts Over tensioning will short en both v belt and bearing life Under tensioning will cause belt slippage Always keep belts free from dirt grease oil and other foreign material which may cause...

Страница 14: ...large O ring is even with the top of the next belt or with the bottom of a straight edge laid across the sheaves Read the force applied from the bottom of the small O ring on the deflection force sca...

Страница 15: ...500 1740 1741 3000 15 5 14 6 23 4 21 8 17 1 16 8 25 5 25 0 8V 12 5 17 0 200 850 851 1500 33 0 26 8 49 3 39 9 200 850 851 1500 39 6 35 3 59 2 52 7 18 0 22 4 Table 2 Sheave Diameter Millimeters Deflect...

Страница 16: ...xtended operation of a dry pump will destroy the seal assembly Add liquid to the pump casing when 1 The pump is being put into service for the first time 2 The pump has not been used for a consider ab...

Страница 17: ...tion line for leaks After the pump has been primed partially close the discharge line throttling valve in order to fill the line slowly and guard against excessive shock pres sure which could damage p...

Страница 18: ...freezing conditions drain the pump to prevent damage from freezing Also clean out any solids by flushing with a hose Operate the pump for approximately one minute this will remove any remaining liqui...

Страница 19: ...e Air leak in suction line Lining of suction hose collapsed Correct leak Replace suction hose Leaking or worn seal or pump gasket Check pump vacuum Replace leaking or worn seal or gasket Suction lift...

Страница 20: ...ng s frozen Disassemble pump and check bearing s Liquid solution too thick Dilute if possible Discharge flow too slow Open discharge valve fully to in crease flow rate and run power source at maximum...

Страница 21: ...ly the same duty cycle the part can be checked and replaced before failure occurs reducing unscheduled down time For new applications a first inspection of wearing parts at 250 hours will give insight...

Страница 22: ...with minimum suction lift Since pump installations are seldom identical your performance may be dif ference due to such factors as viscosity specific gravity elevation temperature and impeller trim If...

Страница 23: ...80 SERIES OM 00856 MAINTENANCE REPAIR PAGE E 2 SECTION DRAWING PARTSPAGE Figure 1 Pump Model 83A2 B...

Страница 24: ...06 15079 1 26 SIGHT GAUGE 26714 011 1 27 PIPE PLUG P06 15079 1 28 SLINGER RING 2351 19120 1 29 STUD C0607 15991 6 30 HEX NUT D06 15991 6 31 SEAL PLATE 388A 10010 1 32 GASKET SET 229G 20010 1 33 HEX HD...

Страница 25: ...the pump 1 Familiarize yourself with this man ual 2 Lock out or disconnect the power source to ensure that the pump will remain inoperative 3 Allow the pump to completely cool if overheated 4 Check th...

Страница 26: ...Remove the outer rotating element Slide the seal plate shaft sleeve and remaining seal parts off the shaft as a unit Carefully remove the stationary and rotating seal elements packing rings and wash e...

Страница 27: ...atches or thread damage on the impeller end Dress small nicks and burrs with a fine file or emery cloth Re place the shaft if defective Clean the bearings thoroughly in fresh cleaning solvent Dry the...

Страница 28: ...al 20 in the bearing retainer 19 with the lip positioned as shown in Figure 1 Press the oil seal into the retainer until fully seated Replace the bearing retainer O ring 24 in the ped estal and lubric...

Страница 29: ...ATIONARY SEAT Figure 3 Seal Assembly This seal is not designed for operation at temperatures above 110_F 43_C Do not use at higher operating temperatures Before installing the seal inspect the bore of...

Страница 30: ...the impeller adjusting shim set until the correct clearance is achieved Pump Casing and Wear Plate Installation If the wear plate assembly 36 was removed install the new wear plate in the pump casing...

Страница 31: ...uge 26 and maintain it at the middle of the gauge When lubrication is required add SAE No 30 non detergent oil through the hole for the air vent 14 Do not over lubricate Over lu brication can cause th...

Страница 32: ...rpumps com warranty or call U S 419 755 1280 International 1 419 755 1352 For Canadian Warranty Information Please Visit www grcanada com warranty or call 519 631 2870 THE GORMAN RUPP COMPANY D MANSFI...