![GORMAN-RUPP PUMPS ULTRA V V3B60-B Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/gorman-rupp-pumps/ultra-v-v3b60-b/ultra-v-v3b60-b_installation-operation-and-maintenance-manual-with-parts-list_2246984034.webp)
OM-06015
ULTRA V SERIES
MAINTENANCE & REPAIR
PAGE E - 12
SEAL PLATE
O‐RINGS
IMPELLER
SHAFT
STATIONARY
SEAT
STATIONARY
ELEMENT
ROTATING
ELEMENT
DRIVE BAND
BELLOWS
IMPELLER
SHIMS
IMPELLER
SPRING
RETAINER
INTEGRAL
SHAFT
SLEEVE
SLEEVE
O‐RING
SPRING
CENTERING
WASHER
SHEAR
RING
(SHEARED)
Figure 5. Cartridge Seal Assembly
This seal is not designed for operation at
temperatures above 160
F (71
C). Do not
use at higher operating temperatures.
If the seal plate was removed, install the seal plate
gasket (5). Position the seal plate over the shaft
and secure it to the bearing housing with the hard
ware (8 and 9).
To prevent damaging the shaft sleeve O‐ring (24)
on the shaft threads, stretch the O‐ring over a piece
of plastic tubing that the I.D. is a little larger than the
O.D. of the shaft. Slide the tube over the shaft
threads, then slide the O‐ring off the tube and onto
the shaft. Remove the tube, and continue to slide
the O‐ring down the shaft until it seats against the
shaft shoulder.
When installing a new cartridge seal assembly
,
remove the seal from the container, and remove
the mylar storage tabs, if so equipped, from be
tween the seal faces.
Some cartridge seal assemblies are
equipped with mylar storage tabs between
the seal faces. These storage tabs
must
be
removed before installing the seal.
Lubricate the external stationary seat O‐ring with
“P-80
Emulsion” or water. Slide the seal assem
bly onto the shaft until the external stationary seat
O‐ring engages the bore in the seal plate.
Clean and inspect the impeller as described in
Im
peller Installation and Adjustment
. Install the full
set of impeller shims (2) provided with the seal, and
screw the impeller onto the shaft until it is seated
against the seal (see Figure 6).