![GORMAN-RUPP PUMPS ULTRA V V3B60-B Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/gorman-rupp-pumps/ultra-v-v3b60-b/ultra-v-v3b60-b_installation-operation-and-maintenance-manual-with-parts-list_2246984033.webp)
OM-06015
ULTRA V SERIES
MAINTENANCE & REPAIR
PAGE E - 11
Figure 2. Press the oil seal into the housing until the
face is
just flush
with the machined surface on the
housing.
Press the oil seal (6) into the bearing cap (18) with
the lip positioned as shown in Figure 2. Replace
the bearing cap gasket (19) and secure the bear
ing cap with the hardware (16 and 17).
Be careful
not to damage the oil seal lip on the shaft keyway.
Lubricate the bearing housing as indicated in
LU
BRICATION
.
Seal Installation
(Figures 2 and 5)
Most cleaning solvents are toxic and
flammable. Use them only in a well ven
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain
ers.
Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent. Inspect the stationary
seat bore in the seal plate for dirt, nicks and burrs,
and remove any that exist. The stationary seat bore
must
be completely clean before installing the
seal.
A new seal assembly should be installed
any time
the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.
Reusing an old seal could result in prema
ture failure.
The seal is not normally reused because wear pat
terns on the finished faces cannot be realigned
during reassembly. This could result in premature
failure. If necessary to reuse an old seal in an emer
gency,
carefully
wash all metallic parts in fresh
cleaning solvent and allow to dry thoroughly.
Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak
age. If any components are worn, replace the com
plete seal;
never mix old and new seal parts
.
If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter.
To ease installation of the seal, lubricate the shaft
sleeve, shaft sleeve O‐ring and the external station
ary seat O‐ring with a very
small
amount of
“P-80
Emulsion” or water. See Figure 5 for seal
part identification.