![GORMAN-RUPP PUMPS ULTRA V Series Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/gorman-rupp-pumps/ultra-v-series/ultra-v-series_installation-operation-and-maintenance-manual-with-parts-list_2246980043.webp)
OM-06295
ULTRA V SERIES
MAINTENANCE & REPAIR
PAGE E - 16
An alternate method of removing the stationary
seal components is to remove the hardware (7 and
8) and separate the seal plate (4) and gasket (5)
from the bearing housing (9). Position the seal
plate on a flat surface with the impeller side down.
Use a wooden dowel or other suitable tool to press
on the back side of the stationary seat until the
seat, O‐rings, and stationary element can be re
moved.
Remove the shaft sleeve O‐ring (29).
If no further disassembly is required, refer to
Seal
Installation
.
Shaft and Bearing Removal and Disassembly
(Figure 5)
When the pump is properly operated and main
tained, the bearing housing should not require dis
assembly. Disassemble the shaft and bearings
only
when there is evidence of wear or damage.
Shaft and bearing disassembly in the field
is not recommended. These operations
should be performed only in a properly‐
equipped shop by qualified personnel.
Remove the bearing housing drain plug (16A) and
drain the lubricant. Clean and reinstall the drain
plug.
Disengage the hardware (17 and 18) and slide the
drive flange (20) and oil seal (19) off the shaft. Re
move the flange gasket (22) and press the oil seal
from the drive flange.
Place a block of wood against the impeller end of
the shaft and tap the shaft and assembled bear
ings (26 and 30) from the bearing housing.
Pry or press the oil seals (6 and 6A) from the bear
ing housing.
After removing the shaft and bearings, clean and
inspect the bearings
in place
as follows.
To prevent damage during removal from
the shaft, it is recommended that bearings
be cleaned and inspected
in place
. It is
strongly
recommended that the bearings
be replaced
any
time the shaft and bear
ings are removed.
Clean the bearing housing, shaft and all compo
nent parts (except the bearings) with a soft cloth
soaked in cleaning solvent. Inspect the parts for
wear or damage and replace as necessary.
Most cleaning solvents are toxic and
flammable. Use them only in a well ven
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain
ers.
Clean the bearings thoroughly in
fresh
cleaning
solvent. Dry the bearings with filtered compressed
air and coat with light oil.
Bearings must be kept free of all dirt and
foreign material. Failure to do so will great
ly shorten bearing life.
Do not
spin dry
bearings. This may scratch the balls or
races and cause premature bearing fail
ure.
Rotate the bearings by hand to check for rough
ness or binding and inspect the bearing balls. If ro
tation is rough or the bearing balls are discolored,
replace the bearings.
The bearing tolerances provide a tight press fit
onto the shaft and a snug slip fit into the bearing
housing. Replace the bearings, shaft, or bearing
housing if the proper bearing fit is not achieved.
If bearing replacement is required, remove the out
board bearing snap ring and thrust washer (24 and
Содержание ULTRA V Series
Страница 29: ...ULTRA V SERIES OM 06295 MAINTENANCE REPAIR PAGE E 2 SECTION DRAWING PARTSPAGE Figure 1 Pump Model V6A60 D914L6 ...
Страница 31: ...ULTRA V SERIES OM 06295 MAINTENANCE REPAIR PAGE E 4 SECTION DRAWING Figure 2 Pump 48157 039 Mounting Kit ...
Страница 33: ...ULTRA V SERIES OM 06295 MAINTENANCE REPAIR PAGE E 6 SECTION DRAWING Figure 3 46143 094 Deutz D914L6 Power Unit ...