![GORMAN-RUPP PUMPS ULTRA V Series Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/gorman-rupp-pumps/ultra-v-series/ultra-v-series_installation-operation-and-maintenance-manual-with-parts-list_2246980025.webp)
OM-06295
ULTRA V SERIES
TROUBLESHOOTING
PAGE D - 1
TROUBLESHOOTING - SECTION D
Review all SAFETY information in Section A.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Turn the keyswitch to `OFF', and
disconnect the positive battery
cable to ensure that the pump will
remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
This pump is equipped with an automat
ic starting system, and is subject to au
tomatic restart. Keep hands and cloth
ing away from the unit to prevent injury
during automatic operation. Disconnect
the positive battery cable before per
forming any maintenance. Failure to do
so may result in serious personal injury.
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO PRIME
Not enough liquid in casing.
Suction check valve contaminated or
damaged.
Air leak in suction line.
Lining of suction hose collapsed.
Leaking or worn seal or pump gas
ket.
Suction lift or discharge head too
high.
Strainer clogged.
Add liquid to casing. See
PRIMING
.
Clean or replace check valve.
Correct leak.
Replace suction hose.
Check pump vacuum. Replace leak
ing or worn seal or gasket.
Check piping installation and install
bypass line if needed. See
INSTAL
LATION
.
Check strainer and clean if neces
sary.
PUMP STOPS OR FAILS
TO DELIVER RATED
FLOW OR PRESSURE
Air leak in suction line.
Lining of suction hose collapsed.
Leaking or worn seal or pump gas
ket.
Strainer clogged.
Suction intake not submerged at
proper level or sump too small.
Correct leak.
Replace suction hose.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Check strainer and clean if neces
sary.
Check installation and correct sub
mergence as needed.