GORMAN-RUPP PUMPS SUPER T2C65SC-B Скачать руководство пользователя страница 29

OM-07334

SUPER T SERIES

MAINTENANCE & REPAIR

PAGE E - 7

necessary and keep personnel away
from suspended objects.

Use 

Only Genuine Gorman-Rupp

 re­

placement parts.  Failure to do so may cre­
ate a hazard and damage the pump or di­
minish optimal pump performance.  Any
such hazard, damage or diminished per­
formance is not covered by the warranty.

NOTE

When appropriate recycling facilities are available,
the user should recycle components and fluids
when doing any routine maintenance / repairs and
also at the end of the pump’s useful life.  All other
components and fluids shall be disposed of ac­
cording to all applicable codes and regulations.

Back Cover and Wear Plate Removal

(Figure 1)

Before attempting to service the pump, remove the
pump casing drain plug (3) and drain the pump.
Clean and reinstall the drain plug.

It is not necessary to remove the inspection cover
(14) to service the wear plate (2). However, if the
O‐ring (9) requires replacement, remove the hard­
ware (10 and 11) and pull the inspection cover out
of the back cover assembly (8). Replace the in­
spection cover O‐ring and reinstall the inspection
cover in the back cover assembly.

The wear plate is easily accessible and may be
serviced by removing the back cover assembly (9).

Remove the back cover nuts (15) and pry the back
cover and assembled wear plate from the pump
casing (1).

NOTE

An alternate method of removing the back cover
from the pump casing is to remove the back cover
nuts (15) and two diagonally opposing locking col­
lars (19). Install two 1/2-13 UNC x 2 inch long
screws in the tapped holes in the back cover and
use them to press the back cover out of the pump

casing. 

Inspect the wear plate and replace it if badly scored
or worn. To remove the wear plate, disengage the
hardware (5 and 6).

Inspect the back cover O‐rings (4 and 7) and re­
place them if damaged or worn.

Suction Check Valve Removal

(Figure 1)

If the check valve assembly (26) is to be serviced,
remove the hardware (28 and 29) and remove the
check valve cover (27). Pull the complete check
valve assembly from the pump casing (1).

NOTE

Further disassembly of the check valve is not re­
quired since it must be replaced as a complete unit.
Individual parts are not sold separately.

Rotating Assembly Removal

(Figure 2)

The rotating assembly may be serviced without
disconnecting the suction or discharge piping;
however, the power source must be removed to
provide clearance.

The impeller (1) should be loosened while the rotat­
ing assembly is still secured to the pump casing.
Before loosening the impeller, remove the seal cav­
ity drain plug (15) and drain the seal lubricant. This
will prevent the oil in the seal cavity from escaping
when the impeller is loosened. Clean and reinstall
the seal cavity drain plug.

Immobilize the impeller by wedging a block wood
between the vanes and the pump casing and re­
move the impeller capscrew and washer (25 and
26).

Install the shaft key (19). Install a lathe dog on the
drive end of the shaft (18) with the “V” notch posi­
tioned over the shaft key.

With the impeller rotation still blocked, see Figure 3
and use a long piece of heavy bar stock to pry
against the arm of the lathe dog in a counterclock­
wise direction (when facing the drive end of the

Содержание SUPER T2C65SC-B

Страница 1: ...01 August 31 2020 GORMAN RUPP PUMPS www grpumps com 2020 Gorman Rupp Pumps Printed in U S A INSTALLATION OPERATION AND MAINTENANCE MANUAL WITH PARTS LIST SUPER T SERIES PUMPS MODELS T2C65SC B Includi...

Страница 2: ...rial number and e mail address required RECORD YOUR PUMP MODEL AND SERIAL NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this in...

Страница 3: ...g PAGE B 4 DISCHARGE LINES PAGE B 5 Siphoning PAGE B 5 Valves PAGE B 5 Bypass Lines PAGE B 5 AUTOMATIC AIR RELEASE VALVE PAGE B 6 Air Release Valve Installation PAGE B 6 ALIGNMENT PAGE B 7 Coupled Dri...

Страница 4: ...ion Check Valve Removal PAGE E 7 Rotating Assembly Removal PAGE E 7 Impeller Removal PAGE E 8 Seal Removal PAGE E 8 Shaft and Bearing Removal and Disassembly PAGE E 9 Shaft and Bearing Reassembly and...

Страница 5: ...y P O Box 1217 Mansfield Ohio 44901 1217 Phone 419 755 1011 or Gorman Rupp of Canada Limited 70 Burwell Road St Thomas Ontario N5P 3R7 Phone 519 631 2870 For information or technical assistance on the...

Страница 6: ...Allow the pump to completely cool if overheated 4 Check the temperature before opening any covers plates or plugs 5 Close the suction and discharge valves 6 Vent the pump slowly and cau tiously 7 Dra...

Страница 7: ...entilate the area 3 Allow the pump to completely cool 4 Check the temperature before opening any covers plates gauges or plugs 5 Vent the pump slowly and cau tiously 6 Refer to instructions in this ma...

Страница 8: ...ming pressure to 50 of the maximum permissible operating pressure as shown on the pump performance curve For further assistance contact your Gorman Rupp distributor or the Gorman Rupp Company Pump Dim...

Страница 9: ...ontact your Gorman Rupp distributor or the factory to deter mine the repair or updating policy Do not put the pump into service until appropriate action has been taken POSITIONING PUMP Death or seriou...

Страница 10: ...and tap the suction and discharge lines not less than 18 inches 457 2 mm from the suction and discharge ports and install the lines Installation closer to the pump may result in erratic readings SUCT...

Страница 11: ...ciency of one or both pumps To avoid this position the suction inlets so that they are separated by a dis tance equal to at least 3 times the diameter of the suction pipe Suction Line Positioning The...

Страница 12: ...ate the hose and break up any solids grease or other substances likely to cause clogging A bypass line that is returned to a wet well must be secured against being drawn into the pump suction inlet It...

Страница 13: ...Consult the manual accompanying the Air Release Valve for additional information on valve installation and performance Air Release Valve Installation The Automatic Air Release Valve must be inde pende...

Страница 14: ...ng feet and or pedestal feet and the driver mounting bolts should also be tightly secured When checking alignment disconnect the power source to ensure that the pump will remain inoperative Adjusting...

Страница 15: ...o tight there will be excessive power loss and possible bearing failure Select pulleys that will match the proper speed ra tio overspeeding the pump may damage both pump and power source Do not operat...

Страница 16: ...o service for the first time 2 The pump has not been used for a consider able length of time 3 The liquid in the pump casing has evapo rated Once the pump casing has been filled the pump will prime an...

Страница 17: ...ails to prime within five minutes stop it and check the suction line for leaks After the pump has been primed partially close the discharge line throttling valve in order to fill the line slowly and g...

Страница 18: ...ing to open or service the pump 1 Familiarize yourself with this man ual 2 Disconnect or lock out the power source to ensure that the pump will remain inoperative 3 Allow the pump to completely cool i...

Страница 19: ...pumping liquids con taining a large amount of solids drain the pump and flush it thoroughly with clean water To prevent large solids from clogging the drain port and pre venting the pump from complet...

Страница 20: ...r gasket Not enough liquid in casing Add liquid to casing See PRIMING Suction check valve contaminated or damaged Clean or replace check valve Suction check valve or foot valve clogged or binding Clea...

Страница 21: ...eck valve or foot valve clogged or binding Clean valve Suction lift or discharge head too high Check piping installation and install bypass line if needed See INSTAL LATION Impeller clogged or damaged...

Страница 22: ...tely the same duty cycle the part can be checked and replaced before failure occurs reducing unscheduled down time For new applications a first inspection of wearing parts at 250 hours will give insig...

Страница 23: ...sea level with minimum suction lift Since pump installations are seldom identical your performance may be dif ferent due to such factors as viscosity specific gravity elevation temperature and impell...

Страница 24: ...SERIES MAINTENANCE REPAIR PAGE E 2 ILLUSTRATION PARTSPAGE 33 34 7 32 13 11 31 4 20 1 14 8 15 9 7 24 27 26 25 25 5 10 23 23 23 35 3 28 13 21 21 16 29 11 17 22 22 30 12 6 2 11 18 19 Figure 1 Pump Model...

Страница 25: ...UG P04 17090 3 24 SUCTION FLANGE T2C65SC B 38641 039 17180 1 T2C65SC B F 38642 009 17180 1 T2C65SC B FM 38642 006 17180 1 25 SUCTION FLG GSKT 38683 273 19410 2 26 FLAP VALVE 46411 133 24010 1 27 FLAP...

Страница 26: ...PER T SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION 16 17 18 19 20 21 22 23 8 9 16 1 2 3 4 5 6 7 8 24 10 10 11 30 30 12 13 14 14 15 15 28 29 25 26 31 27 4 2 3 SEALAREA DETAIL Figure 2 Repair Rotatin...

Страница 27: ...L SEAL 25258 344 2 17 BALL BEARING 23276 008 1 18 IMPELLER SHAFT 38514 565 1706H 1 19 KEY N0408 17090 1 20 BALL BEARING 23422 408 1 21 RETAINING RING S248 1 22 BRG CAP GASKET 38683 268 19410 1 23 BEAR...

Страница 28: ...and removing the back cover assembly If major repair is required the piping and or power source must be disconnected The following instructions assume complete disassem bly is required Before attempt...

Страница 29: ...l two 1 2 13 UNC x 2 inch long screws in the tapped holes in the back cover and use them to press the back cover out of the pump casing Inspect the wear plate and replace it if badly scored or worn To...

Страница 30: ...All threads are 1 2 inch NPT Do not pre assemble the tool TEE APPROX 6 IN 152 MM LONG APPROX 14 IN 356 MM LONG Figure 4 Rotating Assembly Tool To install the tool remove the vented plug 11 Fig ure 2 f...

Страница 31: ...l from the bearing cap Place a block of wood against the impeller end of the shaft 18 and tap the shaft and assembled bearings 17 and 20 from the bearing housing After removing the shaft and bearings...

Страница 32: ...he shaft Position the outboard bearing 20 on the shaft with the integral retaining ring on the bearing O D toward the drive end of the shaft The bearings may be heated to ease installation An inductio...

Страница 33: ...he seal cavity and shaft with a cloth soaked in fresh cleaning solvent Inspect the stationary seat bore in the seal plate for dirt nicks and burrs and remove any that exist The stationary seat bore mu...

Страница 34: ...UBRICATION after the impeller is in stalled If necessary to reuse an old seal in an emer gency carefully separate the rotating and station ary seal faces from the bellows retainer and sta tionary seat...

Страница 35: ...er washer 26 and capscrew torque the capscrew to 27 30 ft lbs 324 360 in lbs or 3 7 4 1 m kg Rotating Assembly Installation Figure 1 NOTE If the pump has been completely disassembled it is recommended...