GORMAN-RUPP PUMPS SUPER T2C65SC-B Скачать руководство пользователя страница 17

SUPER T SERIES

OM-07334

OPERATION

PAGE C - 2

Consult the operating manual furnished with the
power source before attempting to start the power
source.

If an electric motor is used to drive the pump, re­
move V‐belts, couplings, or otherwise disconnect
the pump from the motor before checking motor
rotation. Operate the motor independently while
observing the direction of the motor shaft, or cool­
ing fan.

If rotation is incorrect on a three‐phase motor, have
a qualified electrician interchange any two of the
three phase wires to change direction. If rotation is
incorrect on a single‐phase motor, consult the liter­
ature supplied with the motor for specific instruc­
tions.

OPERATION

Lines With a Bypass

If a Gorman‐Rupp Automatic Air Release Valve has
been installed, the valve will automatically open to
allow the pump to prime, and automatically close
after priming is complete (see 

INSTALLATION 

for

Air Release Valve operation).

If the bypass line is open, air from the suction line
will be discharged through the bypass line back to
the wet well during the priming cycle. Liquid will
then continue to circulate through the bypass line
while the pump is in operation.

Lines Without a Bypass

Open all valves in the discharge line and start the
power source. Priming is indicated by a positive
reading on the discharge pressure gauge or by a
quieter operation. The pump may not prime imme­
diately because the suction line must first fill with
liquid. If the pump fails to prime within five minutes,
stop it and check the suction line for leaks.

After the pump has been primed, partially close the
discharge line throttling valve in order to fill the line
slowly and guard against excessive shock pres­
sure which could damage pipe ends, gaskets,
sprinkler heads, and any other fixtures connected
to the line. When the discharge line is completely

filled, adjust the throttling valve to the required flow
rate.

Do not operate the pump against a
closed discharge throttling valve for
long periods of time. If operated against
a closed discharge throttling valve,
pump components will deteriorate, and
the liquid could come to a boil, build
pressure, and cause the pump casing to
rupture or explode.

OPERATIONAL CHECKS

Leakage

No leakage should be visible at pump mating sur­
faces, or at pump connections or fittings. Keep all
line connections and fittings tight to maintain maxi­
mum pump efficiency.

Liquid Temperature and Overheating

The 

maximum

 liquid temperature for this pump is

160

F (71

C). Do not apply it at a higher operating

temperature.

Overheating can occur if operated with the valves
in the suction or discharge lines closed. Operating
against closed valves could bring the liquid to a
boil, build pressure, and cause the pump to rup­
ture or explode. If overheating occurs, stop the
pump and allow it to cool before servicing it. Refill

the pump casing

 

with cool liquid.

Allow an over‐heated pump to com­
pletely cool before servicing

Do not re­

move plates, covers, gauges, or fittings
from an over‐heated pump. Liquid with­
in the pump can reach boiling tempera­
tures, and vapor pressure within the
pump can cause parts being disen­

Содержание SUPER T2C65SC-B

Страница 1: ...01 August 31 2020 GORMAN RUPP PUMPS www grpumps com 2020 Gorman Rupp Pumps Printed in U S A INSTALLATION OPERATION AND MAINTENANCE MANUAL WITH PARTS LIST SUPER T SERIES PUMPS MODELS T2C65SC B Includi...

Страница 2: ...rial number and e mail address required RECORD YOUR PUMP MODEL AND SERIAL NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this in...

Страница 3: ...g PAGE B 4 DISCHARGE LINES PAGE B 5 Siphoning PAGE B 5 Valves PAGE B 5 Bypass Lines PAGE B 5 AUTOMATIC AIR RELEASE VALVE PAGE B 6 Air Release Valve Installation PAGE B 6 ALIGNMENT PAGE B 7 Coupled Dri...

Страница 4: ...ion Check Valve Removal PAGE E 7 Rotating Assembly Removal PAGE E 7 Impeller Removal PAGE E 8 Seal Removal PAGE E 8 Shaft and Bearing Removal and Disassembly PAGE E 9 Shaft and Bearing Reassembly and...

Страница 5: ...y P O Box 1217 Mansfield Ohio 44901 1217 Phone 419 755 1011 or Gorman Rupp of Canada Limited 70 Burwell Road St Thomas Ontario N5P 3R7 Phone 519 631 2870 For information or technical assistance on the...

Страница 6: ...Allow the pump to completely cool if overheated 4 Check the temperature before opening any covers plates or plugs 5 Close the suction and discharge valves 6 Vent the pump slowly and cau tiously 7 Dra...

Страница 7: ...entilate the area 3 Allow the pump to completely cool 4 Check the temperature before opening any covers plates gauges or plugs 5 Vent the pump slowly and cau tiously 6 Refer to instructions in this ma...

Страница 8: ...ming pressure to 50 of the maximum permissible operating pressure as shown on the pump performance curve For further assistance contact your Gorman Rupp distributor or the Gorman Rupp Company Pump Dim...

Страница 9: ...ontact your Gorman Rupp distributor or the factory to deter mine the repair or updating policy Do not put the pump into service until appropriate action has been taken POSITIONING PUMP Death or seriou...

Страница 10: ...and tap the suction and discharge lines not less than 18 inches 457 2 mm from the suction and discharge ports and install the lines Installation closer to the pump may result in erratic readings SUCT...

Страница 11: ...ciency of one or both pumps To avoid this position the suction inlets so that they are separated by a dis tance equal to at least 3 times the diameter of the suction pipe Suction Line Positioning The...

Страница 12: ...ate the hose and break up any solids grease or other substances likely to cause clogging A bypass line that is returned to a wet well must be secured against being drawn into the pump suction inlet It...

Страница 13: ...Consult the manual accompanying the Air Release Valve for additional information on valve installation and performance Air Release Valve Installation The Automatic Air Release Valve must be inde pende...

Страница 14: ...ng feet and or pedestal feet and the driver mounting bolts should also be tightly secured When checking alignment disconnect the power source to ensure that the pump will remain inoperative Adjusting...

Страница 15: ...o tight there will be excessive power loss and possible bearing failure Select pulleys that will match the proper speed ra tio overspeeding the pump may damage both pump and power source Do not operat...

Страница 16: ...o service for the first time 2 The pump has not been used for a consider able length of time 3 The liquid in the pump casing has evapo rated Once the pump casing has been filled the pump will prime an...

Страница 17: ...ails to prime within five minutes stop it and check the suction line for leaks After the pump has been primed partially close the discharge line throttling valve in order to fill the line slowly and g...

Страница 18: ...ing to open or service the pump 1 Familiarize yourself with this man ual 2 Disconnect or lock out the power source to ensure that the pump will remain inoperative 3 Allow the pump to completely cool i...

Страница 19: ...pumping liquids con taining a large amount of solids drain the pump and flush it thoroughly with clean water To prevent large solids from clogging the drain port and pre venting the pump from complet...

Страница 20: ...r gasket Not enough liquid in casing Add liquid to casing See PRIMING Suction check valve contaminated or damaged Clean or replace check valve Suction check valve or foot valve clogged or binding Clea...

Страница 21: ...eck valve or foot valve clogged or binding Clean valve Suction lift or discharge head too high Check piping installation and install bypass line if needed See INSTAL LATION Impeller clogged or damaged...

Страница 22: ...tely the same duty cycle the part can be checked and replaced before failure occurs reducing unscheduled down time For new applications a first inspection of wearing parts at 250 hours will give insig...

Страница 23: ...sea level with minimum suction lift Since pump installations are seldom identical your performance may be dif ferent due to such factors as viscosity specific gravity elevation temperature and impell...

Страница 24: ...SERIES MAINTENANCE REPAIR PAGE E 2 ILLUSTRATION PARTSPAGE 33 34 7 32 13 11 31 4 20 1 14 8 15 9 7 24 27 26 25 25 5 10 23 23 23 35 3 28 13 21 21 16 29 11 17 22 22 30 12 6 2 11 18 19 Figure 1 Pump Model...

Страница 25: ...UG P04 17090 3 24 SUCTION FLANGE T2C65SC B 38641 039 17180 1 T2C65SC B F 38642 009 17180 1 T2C65SC B FM 38642 006 17180 1 25 SUCTION FLG GSKT 38683 273 19410 2 26 FLAP VALVE 46411 133 24010 1 27 FLAP...

Страница 26: ...PER T SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION 16 17 18 19 20 21 22 23 8 9 16 1 2 3 4 5 6 7 8 24 10 10 11 30 30 12 13 14 14 15 15 28 29 25 26 31 27 4 2 3 SEALAREA DETAIL Figure 2 Repair Rotatin...

Страница 27: ...L SEAL 25258 344 2 17 BALL BEARING 23276 008 1 18 IMPELLER SHAFT 38514 565 1706H 1 19 KEY N0408 17090 1 20 BALL BEARING 23422 408 1 21 RETAINING RING S248 1 22 BRG CAP GASKET 38683 268 19410 1 23 BEAR...

Страница 28: ...and removing the back cover assembly If major repair is required the piping and or power source must be disconnected The following instructions assume complete disassem bly is required Before attempt...

Страница 29: ...l two 1 2 13 UNC x 2 inch long screws in the tapped holes in the back cover and use them to press the back cover out of the pump casing Inspect the wear plate and replace it if badly scored or worn To...

Страница 30: ...All threads are 1 2 inch NPT Do not pre assemble the tool TEE APPROX 6 IN 152 MM LONG APPROX 14 IN 356 MM LONG Figure 4 Rotating Assembly Tool To install the tool remove the vented plug 11 Fig ure 2 f...

Страница 31: ...l from the bearing cap Place a block of wood against the impeller end of the shaft 18 and tap the shaft and assembled bearings 17 and 20 from the bearing housing After removing the shaft and bearings...

Страница 32: ...he shaft Position the outboard bearing 20 on the shaft with the integral retaining ring on the bearing O D toward the drive end of the shaft The bearings may be heated to ease installation An inductio...

Страница 33: ...he seal cavity and shaft with a cloth soaked in fresh cleaning solvent Inspect the stationary seat bore in the seal plate for dirt nicks and burrs and remove any that exist The stationary seat bore mu...

Страница 34: ...UBRICATION after the impeller is in stalled If necessary to reuse an old seal in an emer gency carefully separate the rotating and station ary seal faces from the bellows retainer and sta tionary seat...

Страница 35: ...er washer 26 and capscrew torque the capscrew to 27 30 ft lbs 324 360 in lbs or 3 7 4 1 m kg Rotating Assembly Installation Figure 1 NOTE If the pump has been completely disassembled it is recommended...

Страница 36: ...er into the pump casing until the wear plate just touches the impeller when the shaft is turned by hand Tighten the back cover nuts evenly to avoid binding With the wear plate just touching the impell...

Страница 37: ...een properly lubricated see LUBRICATION Remove the fill cover assembly 31 and fill the pump casing with clean liquid Reinstall the fill cover and tighten it Refer to OPERATION Section C before putting...

Страница 38: ...For Warranty Information Please Visit www grpumps com warranty or call U S 419 755 1280 Canada 519 631 2870 International 1 419 755 1352 GORMAN RUPP PUMPS...

Отзывы: