GORMAN-RUPP PUMPS SUPER T T6A60S-4045T Series Скачать руководство пользователя страница 17

OM-06845

SUPER T SERIES

OPERATION

PAGE C - 1

OPERATION - SECTION C

OPERATION

Review all SAFETY information in Section A.

Follow the instructions on all tags, labels and
decals attached to the pump.

Do not operate an internal combustion
engine in an explosive atmosphere.
When operating an internal combustion
engine in an enclosed area, make sure
exhaust fumes are piped to the outside.
These fumes contain carbon monoxide,
a deadly gas that is colorless, tasteless
and odorless.

This pump is designed to handle

 

most

non‐volatile, non‐flammable liquids
containing specified entrained solids
and corrosives. Do not attempt to pump
volatile, corrosive, or flammable liquids
which may damage the pump or endan­
ger personnel as a result of pump fail­
ure.

Pump speed and operating condition
points must be within the continuous per­
formance range shown on the perfor­
mance curve on page E-1.

STARTING

Check the fuel level and oil levels in the engine, air
compressor, pump bearings and seal housing.

Make sure the pump is level. Lower the jack stands
and chock the wheels, if so equipped.

Make sure the pump is level. Lower jack
stands and chock the wheels, if so
equipped. Use caution when positioning
the skid‐mounted unit to prevent damage
to the fuel tank.

This pump is equipped with an automat­
ic starting system, and is subject to au­
tomatic restart. Keep hands and cloth­
ing away from the unit to prevent injury
during automatic operation. Disconnect
the positive battery cable before per­
forming any maintenance. Failure to do
so may result in serious personal injury.

Consult the engine operations manual before at­
tempting to start the unit.

Consult the manual accompanying the engine
control box and start the pump.

PRIMING

Install the pump and piping as described in 

IN­

STALLATION

. Make sure that the piping connec­

tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri­
cated (see 

LUBRICATION

 in 

MAINTENANCE

AND REPAIR

).

This pump is self‐priming, but the pump should
never be operated unless there is liquid in the
pump casing.

Never operate this pump unless there is
liquid in the pump casing. The pump will
not prime when dry. Extended operation of
a dry pump will destroy the seal assembly.

Содержание SUPER T T6A60S-4045T Series

Страница 1: ...October 28 2016 Rev A 03 08 19 GORMAN RUPP PUMPS www grpumps com e2016 Gorman Rupp Pumps Printed in U S A INSTALLATION OPERATION AND MAINTENANCE MANUAL WITH PARTS LIST SUPER T SERIESr PUMP MODEL T6A60...

Страница 2: ...NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this information when you require parts or service Pump Model Serial Number The...

Страница 3: ...ction Lines In Sumps PAGE B 4 Suction Line Positioning PAGE B 4 FLOAT SWITCHES PAGE B 5 Installation PAGE B 5 OPTIONAL SUBMERSIBLE TRANSDUCER PAGE B 6 DISCHARGE LINES PAGE B 7 Siphoning PAGE B 7 Valve...

Страница 4: ...SSEMBLY AND REASSEMBLY PAGE E 11 Back Cover And Wear Plate Removal PAGE E 12 Suction Check Valve Removal PAGE E 12 Separating Intermediate And Drive Assembly From Engine PAGE E 12 Loosening Impeller P...

Страница 5: ...y P O Box 1217 Mansfield Ohio 44901 1217 Phone 419 755 1011 or Gorman Rupp of Canada Limited 70 Burwell Road St Thomas Ontario N5P 3R7 Phone 519 631 2870 For information or technical assistance on the...

Страница 6: ...c restart Keep hands and cloth ing away from the unit to prevent injury during automatic operation Disconnect the positive battery cable before per forming any maintenance Failure to do so may result...

Страница 7: ...combustion engines in an enclosed area make cer tain that exhaust fumes are piped to the outside These fumes contain carbon monoxide a deadly gas that is color less tasteless and odorless Fuel used b...

Страница 8: ...ic application Since the pressure supplied to the pump is critical to performance and safety be sure to limit the incoming pressure to 50 of the maximum permissible operating pressure as shown on the...

Страница 9: ...d the battery termi nals Secure the battery by tightening the holddown brackets The terminals and clamps may be coated with petroleum jelly to retard corro sion Connect and tighten the positive cable...

Страница 10: ...bration decreased bearing life and increased shaft and seal wear If hose type lines are used they should have adequate support to secure them when filled with liquid and under pressure Gauges Most pum...

Страница 11: ...ng the suction line will re duce pump efficiency If it is necessary to position inflow close to the suc tion inlet install a baffle between the inflow and the suction inlet at a distance 1 1 2 times t...

Страница 12: ...on hose is used it may be extended to lay along the bottom of the wet well or sump and the float can be attached to the hose above the point where it bends along the bot tom Direct the suction line to...

Страница 13: ...ower the transducer into the wet well or sump do not drop it to the bottom To avoid clogging sus pend the transducer off the bottom b Be sure to provide sufficient room in the wet well or sump so that...

Страница 14: ...nd a system check valve be in stalled in the discharge line to protect the pump from excessive shock pressure and reverse rota tion when it is stopped If the application involves a high discharge head...

Страница 15: ...e Gorman Rupp Company for selection of an Automatic Air Release Valve to fit your application Except in certain specific applications to prevent flooding during service of an auto matic air release va...

Страница 16: ...ion Connect the valve outlet to a bleed line which slopes back to the wet well or sump The bleed line must be the same size as the outlet opening or larger depending on which Air Release Valve is be i...

Страница 17: ...vel Lower the jack stands and chock the wheels if so equipped Make sure the pump is level Lower jack stands and chock the wheels if so equipped Use caution when positioning the skid mounted unit to pr...

Страница 18: ...pass line or the bypass line may be left open A manual shut off valve should not be installed in any bypass line A manual shut off valve may inadvertently be left closed during operation A pump which...

Страница 19: ...f rapidly after stabilization an air leak exists Before checking for the source of the leak check the point of installa tion of the vacuum gauge Liquid Temperature And Overheating The maximum liquid t...

Страница 20: ...DIC CHECKS Seal Cavity and Bearing Lubrication Both the seal and bearing cavities were fully lubri cated at the factory Check the lubrication levels before startup and regularly thereafter as indi cat...

Страница 21: ...hose Operate the pump for approximately one minute this will remove any remaining liquid that could freeze the pump rotat ing parts If the pump will be idle for more than a few hours or if it has been...

Страница 22: ...during automatic operation Disconnect the positive battery cable before per forming any maintenance Failure to do so may result in serious personal injury Table 1 Trouble Shooting Chart TROUBLE POSSI...

Страница 23: ...auge Re duce lift and or friction losses in suction line Check engine output consult en gine operation manual Check EPS limit settings check and clean submersible transducer PUMP REQUIRES TOO MUCH POW...

Страница 24: ...help assure trouble free performance and long life from your Gorman Rupp pump For specific questions con cerning your application contact your Gorman Rupp distributor or the Gorman Rupp Company Recor...

Страница 25: ...r Impeller Clearance Seal Plate I Check Valve I Pressure Relief Valve If So Equipped C Pump and Driver Alignment I Shaft Deflection I Bearings I Bearing Housing I Piping I Driver Lubrication See Mfgr...

Страница 26: ...level with minimum suction lift Since pump installations are seldom identical your performance may be dif ferent due to such factors as viscosity specific gravity elevation temperature and impeller t...

Страница 27: ...SUPER T SERIES OM 06845 MAINTENANCE REPAIR PAGE E 2 ILLUSTRATION PARTSPAGE 1 4 2 3 Figure 1 Pump Model T6A60S 4045T FT4...

Страница 28: ...standard production model Contact the Gorman Rupp Company to verify part numbers ITEM NO PART NAME PART NUMBER QTY 1 PUMP END ASSY 46186 050 1 2 POWER UNIT KIT 46143 186 1 3 BATTERY SEE OPTIONS REF 4...

Страница 29: ...SUPER T SERIES OM 06845 MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION 2 1 17 19 9 22 21 19 8 6 5 7 4 20 22 23 24 13 14 16 15 3 11 12 18 25 10 A DETAILA Figure 2 Power Unit Kit...

Страница 30: ...1 118 1 12 1 0 NEGATIVE CABLE ASSEMBLY 47311 133 1 13 3 8 ID X 30 LG HOSE 18513 302 1 14 CABLE TIE 27111 218 1 15 HOSE BARB FITTING 26523 447 1 16 AIR VENT S1703 1 17 LOCKING FUEL CAP 29332 111 1 18 3...

Страница 31: ...ER T SERIES OM 06845 MAINTENANCE REPAIR PAGE E 6 ILLUSTRATION 28 32 31 36 20 25 6 26 9 15 18 33 34 24 21 8 14 35 17 7 3 3 3 10 19 22 23 4 27 16 16 12 5 1 29 5 30 13 18 11 12 2 Figure 3 Pump End Assemb...

Страница 32: ...NDLE 12354 13010 1 22 HEX HEAD CAP SCREW B0804 1 2 15991 4 23 HEX HEAD CAP SCREW B0604 15991 2 24 LOCK COLLAR 38115 551 15001 4 25 ADJUSTING SCREW 31871 070 1500G 4 26 BACK COVER NUT 31871 073 15000 4...

Страница 33: ...OM 06845 MAINTENANCE REPAIR PAGE E 8 ILLUSTRATION 13 15 4 18 21 17 20 19 23 16 22 16 1 2 5 4 26 3 24 4 25A 25 12 11 10 9 7 6 8 14 27 28 29 29 30 31 32 REPAIR ROTATING ASSEMBLY REF Figure 4 Repair Rot...

Страница 34: ...NG 25154 026 REF 15 IMPELLER SHAFT 38514 823 1706H 1 16 INTERMEDIATE GUARD 42381 509 24152 2 17 KEY N0607 15990 1 18 BEARING CAP GASKET 38683 478 18000 1 19 BALL BEARING S1030 1 20 SNAP RING 24124 425...

Страница 35: ...TY 1 COUPLING KIT 48112 001 1 2 BUSHING 24131 345 1 3 COUPLING ASSEMBLY 44165 011 1 4 LOCKWASHER J06 15991 8 4 LOCKWASHER 21171 536 8 5 SOCKET HD CAPSCREW BD0606 1 2 15991 8 5 SOCKET HD CAPSCREW 22644...

Страница 36: ...this manual cannot possibly antici pate and provide detailed instructions and precautions for every situation that might occur during maintenance of the unit Therefore it is the responsibility of the...

Страница 37: ...r worn Suction Check Valve Removal Figure 3 If the check valve assembly 30 is to be serviced remove the check valve pin 32 reach through the back cover opening and pull the complete assem bly from the...

Страница 38: ...with the V notch positioned over the shaft key With the impeller rotation still blocked see Figure 6 and use a long piece of heavy bar stock to pry against the arm of the lathe dog in a counterclock w...

Страница 39: ...parate the seal plate 3 and gasket 5 from the bearing housing 8 Position the seal plate on a flat surface with the impeller side down Use a wooden dowel or other suitable tool to press on the back sid...

Страница 40: ...bearing puller to remove the bearings from the shaft Shaft and Bearing Reassembly and Installation Figure 4 Clean the bearing housing shaft and all compo nent parts except the bearings with a soft clo...

Страница 41: ...the O D of the lip seal area of the shaft With the lip seal sleeve in place lubricate the lip seal area of the shaft and slide the shaft and as sembled bearings into the bearing housing until the ret...

Страница 42: ...housing O ring 28 and lubricate it with light grease To prevent damaging the shaft sleeve O ring 14 on the shaft threads stretch the O ring over a piece of tubing just large enough to slide over the s...

Страница 43: ...sembly should be installed any time the old seal is removed from the pump Wear patterns on the finished faces cannot be realigned during reassembly Reusing an old seal could result in prema ture failu...

Страница 44: ...has been installed in the pump casing this clearance may be measured by reaching through the priming port with a feeler gauge Rotating Assembly Installation Figure 3 NOTE If the pump has been complet...

Страница 45: ...ss the back cover into the pump casing until the wear plate just touches the impeller when the shaft is turned by hand Tighten the back cover nuts evenly to avoid binding With the wear plate just touc...

Страница 46: ...to 45 ft lbs 540 in lbs or 6 2 m kg Using a suitable lifting device position the pump end so the flexible portion of the coupling seats in side the outer ring attached to the engine flywheel NOTE To e...

Страница 47: ...ith approximately 64 ounces 1 9 liter of SAE No 30 non detergent oil to the middle of the sight gauge 24 and maintain it at the middle of the gauge Clean and reinstall the vented plug Maintain the oil...

Страница 48: ...For Warranty Information Please Visit www grpumps com warranty or call U S 419 755 1280 Canada 519 631 2870 International 1 419 755 1352 GORMAN RUPP PUMPS...

Отзывы: