GORMAN-RUPP PUMPS PA Seris Скачать руководство пользователя страница 34

PA SERIES

OM-06575

MAINTENANCE & REPAIR

PAGE E - 14

Use caution when handling hot bearings to
prevent burns.

NOTE

If a hot oil bath is used to heat the bearings, both the
oil and the container must be 

absolutely

 clean. If

the oil has been previously used, it must be 

thor­

oughly

 filtered.

Heat the bearings to a uniform temperature 

no

higher than

 250

F (120

C). Position the roller

bearing (34) on the shaft with the internal snap ring
positioned away from the impeller end of the shaft.
Slide the roller bearing onto the shaft until fully
seated against the shaft shoulder. This should be
done quickly, in one continuous motion, to prevent
the bearings from cooling and sticking on the shaft.

After the bearing has been installed and allowed to
cool, check to ensure that it has not moved away
from the shaft shoulder in shrinking. If movement
has occurred, use a suitably sized sleeve and a
press to reposition the bearing against the shaft
shoulder.

Secure the roller bearing on the shaft with the bear­
ing retaining ring (55).

Slide the heated outboard bearings (30) onto the
shaft, one at a time, with the larger inner races of
each bearing positioned away from each other as
shown in Detail E, Figure 3.

If heating the bearings is not practical, use a suit­
ably sized sleeve and an arbor (or hydraulic) press
to install the bearings on the shaft.

When installing the bearings onto the
shaft, 

never

 press or hit against the outer

race, balls, or ball cage. Press 

only

 on the

inner race.

After the bearings have been installed and allowed
to cool, check to ensure that they have not moved
away from the shaft shoulders in shrinking. If
movement has occurred, use a suitably sized
sleeve and a press to reposition the bearings
against the shaft shoulder.

Secure the assembled shaft and bearings by
clamping on the surface between the bearings.
Use caution not to scratch or mar the part number
etched into the shaft in this area. Install the tab
washer (28) and bearing lock nut (27). Torque the
lock nut to 150 ft. lbs. (1800 in. lbs. or 20,7 m. kg.).
Locate the tab on the lock washer that aligns with a
slot in the lock nut, and bend the tab over into the
slot.

Slide the shaft and assembled bearings into the
pedestal from the drive end until the outer race on
the inboard ball bearing (30) seats against the ped­
estal bore.

When installing the shaft and bearings into
the bearing bore, push against the outer
race. 

Never

 hit the balls or ball cage.

Press the oil seal (23) into the bearing cap (24) with
the lip positioned as shown in Figure 3. Lubricate
and install a new bearing cap O‐ring (25) and se­
cure the bearing cap with the capscrews (22). Use
caution not to cut or roll the lip of the oil seal when
installing the bearing cap.

Press the oil seal (23) into the bearing cap (35) with
the lip positioned as shown in Figure 3. Replace
the bearing cap gasket (29) and secure the bear­
ing cap with the capscrews (22). Use caution not to
cut or roll the lip of the oil seal when installing the
bearing cap.

Lubricate the pedestal as indicated in 

LUBRICA­

TION

.

Seal Reassembly and Installation

(Figures 2 and 6)

Clean the bore of the seal plate (40), the seal plate
cover (45) and the shaft (32) with a cloth soaked in
fresh cleaning solvent.

Содержание PA Seris

Страница 1: ...OM 06575 05 July 24 2012 GORMAN RUPP PUMPS www grpumps com 2012 Gorman Rupp Pumps Printed in U S A INSTALLATION OPERATION AND MAINTENANCE MANUAL WITH PARTS LIST PA SERIES PUMP MODEL PA12A60 B...

Страница 2: ...rial number and e mail address required RECORD YOUR PUMP MODEL AND SERIAL NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this in...

Страница 3: ...HARGE LINES PAGE B 4 Siphoning PAGE B 4 Valves PAGE B 4 ALIGNMENT PAGE B 4 Coupled Drives PAGE B 5 Drive Belts PAGE B 5 DRIVE BELT TENSIONING PAGE B 6 General Rules of Tensioning PAGE B 6 COLD WEATHER...

Страница 4: ...emoval PAGE E 11 Impeller Removal PAGE E 12 Seal Removal PAGE E 12 Pedestal Assembly Removal PAGE E 12 Shaft and Bearing Removal and Disassembly PAGE E 12 Bearing Cleaning And Inspection PAGE E 13 Sha...

Страница 5: ...this manual or in other lit erature accompanying the unit please contact your Gorman Rupp distributor or the Gorman Rupp Company The Gorman Rupp Company P O Box 1217 Mansfield Ohio 44901 1217 Phone 41...

Страница 6: ...pump This pump is designed to handle most non volatile non flammable liquids containing specified entrained solids Do not attempt to pump volatile corro sive or flammable materials which may damage th...

Страница 7: ...s will deteriorate and the liquid could come to a boil build pressure and cause the pump casing to rupture or explode Do not attempt to disengage any part of an overheated pump unit Vapor pres sure wi...

Страница 8: ...re at mating sur faces c Carefully read all tags decals and markings on the pump assembly and perform all duties indicated Note that the pump shaft rotates in the required direction Only operate this...

Страница 9: ...ex actly with the pump port Never pull a pipe line into place by tightening the flange bolts and or cou plings Lines near the pump must be independently sup ported to avoid strain on the pump which co...

Страница 10: ...to the sump and air entering the suction line will re duce pump efficiency If it is necessary to position inflow close to the suc tion inlet install a baffle between the inflow and the suction inlet a...

Страница 11: ...hrottling valve be installed in the discharge line to protect the pump from excessive shock pres sure and reverse rotation when it is stopped If the application involves a high discharge head graduall...

Страница 12: ...ds are the same distance apart at all points see Fig ure 2 Figure 2 Aligning Spider Type Couplings Figure 3 Aligning Non Spider Type Couplings Align non spider type couplings by using a feeler gauge o...

Страница 13: ...as a facto ry installed option or as a retrofit kit for most mod els consult the factory This method pumps heat ed liquid from the engine cooling system through the priming chamber to heat the chamber...

Страница 14: ...lectrician interchange any two of the three phase wires to change direction If rotation is incorrect on a single phase motor consult the liter ature supplied with the motor for specific instruc tions...

Страница 15: ...y Strainer Check Check the strainer regularly and clean it as neces sary The strainer should also be checked if pump flow rate begins to drop Monitor and record the vacuum suction gauge readings regul...

Страница 16: ...f the pump will be idle for more than a few hours or if it has been pumping liquids containing a large amount of solids drain the pump and flush it thoroughly with clean water To prevent large solids...

Страница 17: ...rrect leak Lining of suction hose collapsed Replace suction hose Leaking or worn seal or pump gasket Check pump vacuum Replace leaking or worn seal or gasket Air compressor damaged or belts bro ken Ch...

Страница 18: ...ble check and replace bearing s as required Liquid solution too thick Open discharge valve fully to in crease flow rate and run engine at maximum governed speed Discharge flow too slow Dilute if possi...

Страница 19: ...e schedule will help assure trouble free performance and long life from your Gorman Rupp pump For specific questions con cerning your application contact your Gorman Rupp distributor or the Gorman Rup...

Страница 20: ...mpeller Clearance Seal Plate I Check Valve I Pressure Relief Valve If So Equipped C Pump and Driver Alignment I Shaft Deflection I Bearings I Bearing Housing I Piping I Driver Lubrication See Mfgr s L...

Страница 21: ...with minimum suction lift Since pump installations are seldom identical your performance may be dif ferent due to such factors as viscosity specific gravity elevation temperature and impeller trim If...

Страница 22: ...OM 06575 PA SERIES MAINTENANCE REPAIR PAGE E 2 PARTSPAGE ILLUSTRATION 6 7 12 13 15 14 17 16 18 11 10 20 19 2 1 3 4 3 5 6 7 9 8 Figure 1 PA12A60 B Pump Model Assembly...

Страница 23: ...WASHER J14 15991 24 7 HEX NUT D14 15991 24 8 CHECK VALVE 12 26642 128 1 FLAPPER 26688 003 1 GASKET 26688 004 1 O RING 25152 469 1 9 DRAIN VALVE ASSY 46346 262 1 10 PIPE PLUG P04 15079 1 11 12 SPOOL 38...

Страница 24: ...OM 06575 PA SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION SEE FIG 3 Figure 2 Pump End Assembly...

Страница 25: ...29 BEARING CAP GASKET 4184G 18000 1 30 BALL BEARING 23413 015 2 31 KEY N1016 15990 1 32 IMPELLER SHAFT 38512 522 17040 1 33 KEY N0809 15990 1 34 ROLLER BEARING 23528 005 1 35 BEARING CAP 38322 425 100...

Страница 26: ...OM 06575 PA SERIES MAINTENANCE REPAIR PAGE E 6 ILLUSTRATION SEE FIG 2 Figure 3 Pump End Assembly Cont d...

Страница 27: ...5 1 29 BEARING CAP GASKET 4184G 18000 1 30 BALL BEARING 23413 015 2 31 KEY N1016 15990 1 32 IMPELLER SHAFT 38512 522 17040 1 33 KEY N0809 15990 1 34 ROLLER BEARING 23528 005 1 35 BEARING CAP 38322 425...

Страница 28: ...LIST ITEM NO PART NAME PART NUMBER QTY 1 PRIMING VALVE 26664 007 1 ORIFICE BUTTON 26688 021 1 2 HEX HD CAPSCREW B0806 15991 8 3 LOCKWASHER J08 15991 8 4 PRIMING VALVE GASKET 38683 657 19060 1 5 PRIMIN...

Страница 29: ...OM 06575 PA SERIES MAINTENANCE REPAIR PAGE E 9 ILLUSTRATION WEAR RING IMPELLER NOTE UNLESS OTHERWISE SPECIFIED MACHINED SURFACES TO BE 125 RMS Figure 5 Impeller Assembly Machining Tolerances...

Страница 30: ...n the suction and discharge lines For power source disassembly and repair consult the literature supplied with the power source or contact your local power source representative Before attempting to o...

Страница 31: ...alve cap and remove the flap per and gasket Suction Head And Wear Ring Removal Figure 2 Unless replacement of the spool gasket 3 Figure 1 is required the suction head 49 may be re moved without separa...

Страница 32: ...ring to the impeller Use caution not to damage the impeller Pry or carefully grind the wear ring off the impeller Seal Removal Figures 2 and 6 This pump is designed with two seals a primary mechanica...

Страница 33: ...ection Figure 3 Clean the bearing housing shaft and all compo nent parts except the bearings with a soft cloth soaked in cleaning solvent Inspect the parts for wear or damage and replace as necessary...

Страница 34: ...een installed and allowed to cool check to ensure that they have not moved away from the shaft shoulders in shrinking If movement has occurred use a suitably sized sleeve and a press to reposition the...

Страница 35: ...gency carefully wash all metallic parts in fresh cleaning solvent and allow to dry thoroughly Handle the seal parts with extreme care to prevent damage Be careful not to contaminate precision finishe...

Страница 36: ...INTENANCE REPAIR PAGE E 16 IMPELLER SHAFT SPRING SEAL PLATE RETAINER O RINGS BELLOWS ROTATING ELEMENT STATIONARY SEAT SLEEVE O RING IMPELLER STATIONARY ELEMENT SHAFT SLEEVE SHAFT KEY IMPELLER SHIMS Fi...

Страница 37: ...es machining and dynamic balancing the im peller assembly after the wear ring is welded to the impeller Failure to properly install the wear ring and machine and bal ance the impeller assembly can res...

Страница 38: ...to service Discharge Check Valve Assembly and Installation Figure 1 The flapper and gasket are the only serviceable parts of the check valve If the flapper requires re placement remove the hardware se...

Страница 39: ...t of the gauges When lubrication is re quired remove the vented plug 19 and add SAE No 30 non detergent oil through the opening Clean and reinstall the vented plug Do not over lu bricate Over lubricat...

Страница 40: ...For Warranty Information Please Visit www grpumps com warranty or call U S 419 755 1280 Canada 519 631 2870 International 1 419 755 1352 GORMAN RUPP PUMPS...