background image

LEDI 6 – LEDI 6/S 

7 /8 

6.4.1 - Transmitter mode 
 

In this mode, the clock transmits a code (configuration 2400 bauds, 8-bit format, even parity, 1 stop 
bit) which has two parts: 

1- time information in the form: 

STX day of week SP day of month/month/year SP SP hour:minute:second CR 

 

2 - status information (timer, temperature, brightness, etc.). 

The first part of the information sequence serves, for example, to synchronise a computer (in this 
case the second part is not taken into account). 
The complete information sequence is used to control another clock. 
 

6.4.2 - Receiver mode 
 

In this mode, the clock works autonomously but is set with respect to the ASCII code that it receives 
(configuration 2400 bauds, 8-bit format, even parity, 1 stop bit). This ASCII code may be either: 
- time information in the form: 

STX day of week SP day of month/month/year SP SP hour:minute:second CR 

generated either by the RT3000 or RADIO TIMING ASCII or any other ASCII code generator, 
- information from another clock of the same type working in transmitter mode; in this case, the clock 
is completely slaved to the other. 
 

6.4.3 - Two-directional mode 
 

In this mode the ASCII coded time message is transmitted after reception of a recognition character 
("D") (configuration 2400 bauds, 8-bit format, even parity, 1 stop bit). 
Message transmitted: 
 

STX hundredth of second SP day of week SP day of month/month/year SP SP 

 hour:minute:second 

CR 

e.g. 76 FRI 03/02/90  15:14:45 

which means that the second corresponding to this message is 76 hundredths of a second over when 
the character "D" is received.  
N.B.:   - In the case of the LEDI 6 (indicating only hour and minute information), the date information 
is replaced by zeros and the day of the week in alphanumeric characters  by three spaces. However, 
if this clock is an AFNOR NFS 87-500 receiver or is radio-synchronised, the date information is 
generated. 
If there is a mains cut, the display goes out but the clock continues to run on its internal battery (the 
hour pips and ASCII output are no longer generated). 
 
 

- For ASCII code receiver clocks, if the incoming message is not in the correct configuration, it 

may be necessary to set the clock manually. As soon as the ASCII message is received, the clock 
compensates for any difference with the reference time. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание LEDI 6

Страница 1: ...LEDI 6 LEDI 6 S USER MANUAL STANDARD FLUSH MOUNTED or WATERTIGHT CASE...

Страница 2: ...7 65 135 Made in France N serie Impuls 230V SW1 OFF ON PROG B1 B2 B3 B4 230V Fig 1 B1 Input PROG 320 Fig 2 Fig 3 Fig 4 2 x diam 4 2 3 1 2 1 Use the lever to make the connections input MOUNTING PRINCIP...

Страница 3: ...ED numerical display of hours minutes seconds S option Height of figures 60 mm Inclination of figures 10 Legibility 25 metres Power supply 230 V 10 50 60 Hz 115 V AC or 48 V AC optional Consumption 6...

Страница 4: ...pport for attaching the bracket Leave at least 60 mm between the top of the case and the ceiling Fix the bracket on the wall support using two 4 mm dia screws Hook the case over the bracket Flush moun...

Страница 5: ...from 1 to 9 seconds 2 adjustment of temperature display time from 1 to 9 seconds 3 adjustment of hours 4 adjustment of minutes SYNCHRONISATION If the minutes have not been modified one press on PROG w...

Страница 6: ...Imax 50 Ma In case of an open collector output the ground is connected to 1 6 2 12 HOUR OPTION This version has the same characteristics as the standard version except that the display goes from 01h0...

Страница 7: ...this case the clock is completely slaved to the other 6 4 3 Two directional mode In this mode the ASCII coded time message is transmitted after reception of a recognition character D configuration 24...

Страница 8: ...LEDI 6 LEDI 6 S 8 8 WARNING ISOLATE BEFORE REMOVE COVER FOR19 A 005D GORGY TIMING RC 74 B Registered trademark and design...