142541
18
Fault:
Cause/Remedy
The appliance does not operate
after connection to the mains:
• Check if there is power in the socket and if the appliance is
switched on.
Cooling system operates
continuously without intermittent
stoppages:
• Check air circulation for suffi cient cooling of the compressor,
and clean the condenser.
• Ambient temperature too high.
• Frequent opening of the door, door open too long.
• Door not closed properly (particle between door gasket,
sagged door, check gasket sealing, etc...).
• Excessive quantity of fresh food inserted at once.
• ‘Intensive freezing’ option is on.
Ice formation within the freezer
interior is a consequence of:
• Bad door sealing; clean or replace the gasket if dirty or
damaged.
• Frequent opening of the door, door open too long.
• Inserting hot food in the freezer.
Red light is on:
• Frequent opening of the door, door open too long.
• Door not closed properly (particle between door gasket,
sagged door, damaged gasket, etc...).
• Excessively long power failure.
• Excessive quantity of fresh food inserted at once.
Diffi cult door opening:
• If you attempt to open the immediately closed door of the
freezer you may experience resistance. This happens
because certain quantity of cold air escapes from the
appliance through the open door and is replaced by warm
ambient air. Cooling of such air creates negative pressure
(vacuum) and suction, which prevents easy opening of the
door. This is normalized after several minutes and you can
open the door with ease.
Bulb replacement (certain models
only):
• Before replacing the light bulb, disconnect the appliance
form the power supply. Remove the plastic cover, replace the
bulb with a new one (E 14, max. same voltage as the factory
one) and fi t back the cover.
• Please dispose of this correctly.
• Light bulb is consumption material and is not covered by the
warranty.
Green LED is fl ashing:
• If the green LED is fl ashing, call the nearest service center.
Occurrence of murmur after
closing the door
• After closing the door, some murmur can occur. This
phenomenon is normal and is due to pressure equalisation
.
Troubleshooting guide
Содержание UKM235XNF
Страница 1: ...Instructions for use Upright freezer ...
Страница 20: ...ZOS 3167 ZOF 2467 FREEZER 142541 en 07 08 ...