TECHNICAL CHARACTERISTICS
KEY TIPE
Y = low temperature operation
NT
– if there is no sign, there is no low temperature
X = installed heater
G
– if there is no sign, there is no heater
Heat pump with an integrated aggregate and one exchanger
Type
TCX 200 Z XY
TCX 201 Z XY
TCX 300 Z XY
TCX 306 Z XY
Use profile
L
L
XL
XL
Energy efficiency class
1)
A+
A+
A+
A+
Energy efficiency of water heating
η
wh
1)
%
128,5
127,0
136,0
134,4
Annual electrical energy consumption
1)
kWh
797
806
1231
1246
Daily electrical energy consumption
1)
kWh
3,762
3,813
5,707
5,787
Set thermostat temperature
°C
55
55
55
55
Level of indoor sound power
3)
dB (A)
59/58
59/58
59/58
59/58
Smart value
0
0
0
0
Storage volume
l
208,0
194,0
295,0
276,0
Mixed water at 40 °C V40
2)
l
260
248
395
368
Potential safety measures
(assembly, installation, maintenance)
Compulsory use of a safety valve with the pressure connection.
Technical characteristics
Heating time A15 / W10-55
4)
h:min
05:21
05:13
08:32
08:00
Heating time A7 / W10-55
5)
h:min
06:24
06:06
09:40
09:39
Energy consumption in the selected cycle of emissions
A15 / W10-55
4)
kWh
3,71
3,86
5,75
5,75
Energy consumption in the selected cycle of emissions
A7 / W10-55
5)
kWh
3,82
3,97
5,80
5,96
COP
DHW
A15/W10-55
4)
3,25
3,12
3,42
3,38
COP
DHW
A7/W10-55
5)
3,10
3,06
3,34
3,30
Power in standby mode
5)
W
24
26
18
20
Refrigerating agent
R134a
R134a
R134a
R134a
Quantity of refrigerant
kg
1,100
1,100
1,100
1,100
Global Warming Potential
1430
1430
1430
1430
Carbon dioxide equivalent
t
1,573
1,573
1,573
1,573
Operation area regular model
°C
7 ÷ 35
7 ÷ 35
7 ÷ 35
7 ÷ 35
Operation area NT
6)
°C
-7 ÷ 35
-7 ÷ 35
-7 ÷ 35
-7 ÷ 35
Area of airflow
m
3
/h
220-450
220-450
220-450
220-450
Max acceptable pressure drop in the pipeline
(volumetric flow rate of a at 330 m
3
/h) (60%)
Pa
100
100
100
100
Electrical characteristics
Specified power of the compressor
W
490
490
490
490
Heater power X
7)
W
2000
2000
2000
2000
Maximum connection power without heater/with heater
W
490/2490
490/2490
490/2490
490/2490
Voltage
V/Hz
230/50
230/50
230/50
230/50
Electrical protection
A
16
16
16
16
Moisture protection
IP24
IP24
IP24
IP24
Water tank
Anti-corrosion protection of tank
Stainless steel
Nominal pressure
MPa
0,6/0,9/1,0
0,6/0,9/1,0
0,6/0,9/1,0
0,6/0,9/1,0
The highest water temperature heat pump
°C
65
65
65
65
The highest water temperature electrical heater
7)
°C
75
75
75
75
Connection measurements
Total height
mm
1540
1540
1960
1960
Width
mm
670
670
670
670
Depth
mm
690
690
690
690
Inlet/outlet water connections
G1
G1
G1
G1
Inlet/outlet air connection dimensions
mm
Ø160
Ø160
Ø160
Ø160
Heating area PT - bottom
m
2
/
1,45
/
1,6
Exchanger connectors
-
G1
-
G1
Weight/Filled with water
kg
104/116/312
133/145/327
123/135/418
177/189/453
The temperature of the heating medium in the heat exchanger
°C
/
5 ÷ 85
/
5 ÷ 85
Transport data
Packaging
mm
800x800x1765
800x800x1765
800x800x2155
800x800x2155
1)
directive 812/2013, 814/2013, EN16147:2011. Average climate conditions
2)
in accordance with EN16147:2011
3)
in accordance with EN12102:2013 (60% fan speed – outside air/40% fan speed – ambient air)
4)
inlet air temperature 15°C, 74% humidity, water temperature between 10 and 55°C in accordance with EN16147:2011
5)
inlet air temperature 7°C, 89% humidity, water temperature between 10 and 55°C in accordance with EN16147:2011
6)
low temperature mode, stated with the typical sign NT - if there is no sign, there is no low temperature operation
7)
installed heater, stated with the typical sign G - if there is no sign, there is no heater
TCX 306 Z XY
22