50
3909
Gas supply connection plug
A
EN ISO 10226-1 / -2 or EN ISO 228-1 (Depending on the
country-specifi c connection regulations.) connection
plug
B
Non-metal gasket with thickness of 2 mm
C
Pipe adapter for liquid gas (Depending on the country-
specifi c connection regulations.)
After the connection, check the burners for correct
operation. The fl ames must be clearly visible, and should
be blue and green at the center. If the fl ame is unstable,
increase the minimum power. Explain the use of the
burners to the user and read the instructions for use
together.
• The procedure or adaptation of the cooker to another
type of gas does not require removal of the appliance
from the worktop.
• Before adapting, disconnect the appliance from the
power mains and close the gas supply valve.
• Replace the existing nozzles for nominal thermal load
with corresponding nozzles for the new gas type (see
table below).
• When adapting the appliance to liquid gas, fasten the
regulation screw for minimum thermal load as far as it
will go, in order to attain minimum thermal load.
• When adapting the appliance to natural gas, release the
minimum thermal load regulation screw in order to attain
minimum thermal load, but do not rotate it by more than
1.5 turns.
Cooker burner
1
Burner crown cover
2
Burner crown with cover support
3
Thermo-element
4
Spark plug
5
Nozzle
Adaptation to a
diff erent type of gas
1
2
3
4
5
19