background image

4

1) BURNERS

A diagram is screen-printed above each knob on the
front  panel.  This  diagram  indicates  to  which  burner
the  knob  in  question  corresponds. After  having
opened  the  gas  mains  or  gas  bottle  tap,  light  the
burners as described below:

- manual ignition

Push  and  turn  the  knob  corresponding  to  the
required  burner  in  an  anticlockwise  direction  until  it
reaches the full on position (large flame fig. 1), then
place a lighted match near the burner.

- Automatic electrical ignition

Push  and  turn  the  knob  corresponding  to  the
required  burner  in  an  anticlockwise  direction  until  it
reaches the full on position (large flame fig. 1), then
depress the knob.

-  Lighting  burners  equipped  with  flame  failure

device

The  knobs  of  burners  equipped  with  flame  failure
device  must  be  turned  in  an  anticlockwise  direction
until they reach the full on position (large flame fig. 1)
and  come  to  a  stop.  Now  depress  the  knob  in
question  and  repeat  the  previously  indicated
operations.
Keep the knob depressed for about 10 seconds once
the burner has ignited.

HOW TO USE THE BURNERS

Bear  in  mind  the  following  indications  in  order  to
achieve maximum efficiency with the least possible
gas consumption:
- use  adequate  pans  for  each  burner  (consult  the

following table and fig. 2).

- When  the  pan  comes  to  the  boil,  set  the  knob  to

the reduced rate position (small flame fig. 1).

- Always place a lid on the pans.
- Use only pan with a flat bottom.

WARNINGS:
- burners  with  flame  failure  device  may  only  be

ignited when the relative knob has been set to
the Full on position (large flame fig. 1).

- Matches can be used to ignite the burners in a

blackout.

- Never leave the appliance unattended when the

burners are being used. Make sure there are no
children  in  the  near  vicinity.  Particularly  make
sure  that  the  pan  handles  are  correctly
positioned and keep a chek on foods requiring
oil  and  grease  to  cook  since  these  products
can easily catch fire.

-  The  machine  must  not  be  used  by  people

(including  children)  with  impaired  mental  or
physical  capacities,  or  without  experience  of
using  electrical  devices,  unless  supervised  or
instructed  by  an  expert  adult  responsible  for
their  care  and  safety.  Children  should  not  be
allowed to play with the equipment.

- Never  use  aerosols  near  the  appliance  when  it

is operating.

-  Containers    wider    than    the    unit    are  not

recommended.

FIG. 1

FIG. 2

Burners

Power 

ratings

Pan Ø 

in cm

Ultra rapid

4500

24 ÷ 26

Auxiliary

1000

10 ÷ 14

USE

Содержание GW721X/HG2VRSMXG0XS

Страница 1: ...COD 04031 24 01 2018 Instructions for the installation and advice for the maintenance Instructions Manual GW721X HG2VRSMXG0XS GW931X HI3VRSMXG0XS ...

Страница 2: ...n aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Warning durin...

Страница 3: ... iron pan support central 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 4 control knob GW721X HG2VRSMXG0XS GW931X HI3VRSMXG0XS Overall measurement mm Width 730 x Depth 430 x Height 50 Overall measurement mm Width 860 x Depth 500 x Height 40 Attention this appliance has been manufactured for domestic use only and it employment by private person ...

Страница 4: ...er to achieve maximum efficiency with the least possible gas consumption use adequate pans for each burner consult the following table and fig 2 When the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom WARNINGS burners with flame failure device may only be ignited when the relative knob has been set to...

Страница 5: ...y more or replace an old model before disposing of it make it inoperative in conformity with current law on the protection of health and the prevention of environmental pollution by making its dangerous parts harmless especially for children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not...

Страница 6: ...C fig 6 and 6 A have correctly positioned on the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they are difficult open or close Contact the technical assistance service for repairs Correctly preserve the plate after use by treating it with special products...

Страница 7: ...liance belongs to class 3 and is therefore subject to all the provisions established by the provisions governing such appliances 5 FIXING THE HOT PLATE The hot plate has a special seal which prevents liquid from infiltrating into the cabinet Strictly comply with the following instructions in order to correctly apply this seal Detach the seals from their backing checking that the transparent protec...

Страница 8: ...perate correctly the necessary amount of air is that required for regular gas combustion and ventilation of the relative room the volume of which must not be less than 20 m3 Air must naturally flow through permanent openings in the walls of the room in question These openings must vent the fumes outdoors and their section must be at least 100 cm2 see fig 3 Construction of the openings must ensure ...

Страница 9: ...led by a pressure governor conforming to the provisions in force and must be connected with a copper pipe The joints of this pipe must consist of unions with mechanical seals With seamless flexible stainless steel pipe The length of this pipe must be 2 meters at most and the seals must comply with the standards It is advisable to apply the special adapter to the flexible pipe This is easily availa...

Страница 10: ...fter the built in When the appliance is connected straight to the electricity main install an omnipolar circuit breaker between the appliance and the electricity main This circuit breaker should be sized according to the load rating of the appliance and possess a minimum 3 mm gap between its contacts Remember that the earth wire must not be interrupted by the circuit breaker The electrical connect...

Страница 11: ... the tap fig 12 or inside the shaft In any case to access to regulation it can be done trought the insertion of a small screwdriver D beside the tap fig 12 or in the hole C inside the shaft of the tap fig 12 A Turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Reduced rate position The flame should not be too low the lowest small flame should b...

Страница 12: ...with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate table also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas CONVERSIONS BURNER ARRANGEMENT ON THE HOT PLATE FIG 13 BURNERS GAS NORMAL PRESSURE mbar NORMAL RATE INJEC...

Страница 13: ...comes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean the cone and its housing using a cloth soaked in diluent Lightly spread the cone with the relative grease Fit the cone back in place operate it several times and then remove it again Eliminate any excess grease and check that the gas ducts have not become clogged Fit all parts b...

Страница 14: ...supply cable is replaced the installer should leave the ground wire B longer than the phase conductors fig 20 and comply with the recommendations given in paragraph 9 TYPE OF HOT PLATE TYPE OF CABLE SINGLE PHASE POWER SUPPLY Gas hot plate H05 RR F Section 3 x 0 75 mm 2 ...

Страница 15: ... 20Y 28 mbar NATURAL G20 12T 20 mbar ΣQn LPG Gas Rate 10 0 kW ΣQn NATURAL G20 Gas Rate 10 0 kW Σ Qn LPG G30 727 g h Voltage 220 240 V Frequency 50 Hz Loading 1 1 w In case of failure or cut in the cable please move away from the cable and do not touch it Moreover the device must be unplugged and not switched on Call the nearest authorized service center to fix the problem GW721X HG2VRSMXG0XS GW931...

Страница 16: ...er Sales Service Centers and authorized retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packing label The above informations give to the technical assistant the possibility to get fit spare parts and a heaven sent intervention We suggest to fill the table below MARK MODEL SERIES TECHNICAL ASSISTANCE AND SPARE PARTS 16 This appliance ...

Отзывы: