9) ELECTRICAL CONNECTION

The electrical connections of the appliance must
be carried out in compliance with the provisions
and standards in force.

Before connecting the appliance, check that:
- the  electrical  capacity  of  the  mains  supply  and

current  sockets  suit  the  maximum  power  rating  of
the  appliance  (consult  the  data  label  applied  to  the
underside of the hot plate).

- The  voltage  matches  the  value  shown  on  the

specification  plate  and  the  section  of  the  wires  of
the electrical system can support the load, which is
also indicated on the specification plate.

-  The  socket  or  system  has  an  efficient  earth

connection  in  compliance  with  the  provisions  and
standards  in  force.  The  manufacturer  declines  all
responsibility  for  failing  to  comply  with  these
provisions.

When  the  appliance  is  connected  to  the
electricity main by a socket:

- apply  to  the  input  cable  "C",  if  unprovided  (see 

fig.  11)  a  normalized  plug  adequate  to  the  load

indicated  in  the  identification  label.  Connect  the
cables  according  to  the  scheme  of  fig.  11,  making
sure to respect the undermentioned respondences:

Letter L (live) = brown wire;

Letter N (neutral) = blue wire;

Earth symbol  

= green - yellow wire.

- The power supply cable must be positioned so that

no  part  of  it  is  able  to  reach  an  temperature  of  90
°C.

-  Never  use  reductions,  adapters  of  shunts  for

connection  since  these  could  create  false  contacts
and lead to dangerous overheating.

-  The outlet must be accessible after the built-in.

When the appliance is connected straight to the
electricity main:

- install  an  omnipolar  circuit-breaker  between  the

appliance  and  the  electricity  main.  This  circuit-

breaker should be sized according to the load rating
of the appliance and possess a minimum 3 mm gap
between its contacts.

-  Remember  that  the  earth  wire  must  not  be

interrupted by the circuit-breaker.

- The electrical connection may also be protected by

a high sensitivity differential circuit- breaker.

You  are  strongly  advised  to  fix  the  relative  yellow-
green earth wire to an efficient earthing system.

Before  performing  any  service  on  the  electrical
part  of  the  appliance,  it  must  absolutely  be
disconnected from the electrical network.

WARNINGS: 
all our products are conform with the 
European Norms and relative amendments.  
The product is therefore conform with the 
requirements of the European Directivesin 
force relating to: 
- compatibility electromagnetic (EMC); 
- electrical security (LVD); 
-  restriction  of  use  of  certain  hazardous

substances (RoHS); 

- EcoDesign (ERP).

10

INSTALLATION

IMPORTANT:  the  appliance  must  be  installed
following the manufacturer's instructions. The
manufacturer  will  not  be  liable  for  injury  to
persons  or  animals  or  property  damage
caused by an incorrect installation.

If  the  installation  requires  modifications  to  the
home's  electrical  system  or  if  the  socket  is
incompatible  with  the  appliance's  plug,  have
changes  or  replacements  performed  by
professionally-qualified  person.  In  particular,
this  person  must  also  make  sure  that  the
section of the wires of the socket is suitable for
the power absorbed by the appliance.

FIG. 11

Содержание GW721X/HG2VRSMXG0XS

Страница 1: ...COD 04031 24 01 2018 Instructions for the installation and advice for the maintenance Instructions Manual GW721X HG2VRSMXG0XS GW931X HI3VRSMXG0XS ...

Страница 2: ...n aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Warning durin...

Страница 3: ... iron pan support central 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 4 control knob GW721X HG2VRSMXG0XS GW931X HI3VRSMXG0XS Overall measurement mm Width 730 x Depth 430 x Height 50 Overall measurement mm Width 860 x Depth 500 x Height 40 Attention this appliance has been manufactured for domestic use only and it employment by private person ...

Страница 4: ...er to achieve maximum efficiency with the least possible gas consumption use adequate pans for each burner consult the following table and fig 2 When the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom WARNINGS burners with flame failure device may only be ignited when the relative knob has been set to...

Страница 5: ...y more or replace an old model before disposing of it make it inoperative in conformity with current law on the protection of health and the prevention of environmental pollution by making its dangerous parts harmless especially for children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not...

Страница 6: ...C fig 6 and 6 A have correctly positioned on the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they are difficult open or close Contact the technical assistance service for repairs Correctly preserve the plate after use by treating it with special products...

Страница 7: ...liance belongs to class 3 and is therefore subject to all the provisions established by the provisions governing such appliances 5 FIXING THE HOT PLATE The hot plate has a special seal which prevents liquid from infiltrating into the cabinet Strictly comply with the following instructions in order to correctly apply this seal Detach the seals from their backing checking that the transparent protec...

Страница 8: ...perate correctly the necessary amount of air is that required for regular gas combustion and ventilation of the relative room the volume of which must not be less than 20 m3 Air must naturally flow through permanent openings in the walls of the room in question These openings must vent the fumes outdoors and their section must be at least 100 cm2 see fig 3 Construction of the openings must ensure ...

Страница 9: ...led by a pressure governor conforming to the provisions in force and must be connected with a copper pipe The joints of this pipe must consist of unions with mechanical seals With seamless flexible stainless steel pipe The length of this pipe must be 2 meters at most and the seals must comply with the standards It is advisable to apply the special adapter to the flexible pipe This is easily availa...

Страница 10: ...fter the built in When the appliance is connected straight to the electricity main install an omnipolar circuit breaker between the appliance and the electricity main This circuit breaker should be sized according to the load rating of the appliance and possess a minimum 3 mm gap between its contacts Remember that the earth wire must not be interrupted by the circuit breaker The electrical connect...

Страница 11: ... the tap fig 12 or inside the shaft In any case to access to regulation it can be done trought the insertion of a small screwdriver D beside the tap fig 12 or in the hole C inside the shaft of the tap fig 12 A Turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Reduced rate position The flame should not be too low the lowest small flame should b...

Страница 12: ...with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate table also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas CONVERSIONS BURNER ARRANGEMENT ON THE HOT PLATE FIG 13 BURNERS GAS NORMAL PRESSURE mbar NORMAL RATE INJEC...

Страница 13: ...comes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean the cone and its housing using a cloth soaked in diluent Lightly spread the cone with the relative grease Fit the cone back in place operate it several times and then remove it again Eliminate any excess grease and check that the gas ducts have not become clogged Fit all parts b...

Страница 14: ...supply cable is replaced the installer should leave the ground wire B longer than the phase conductors fig 20 and comply with the recommendations given in paragraph 9 TYPE OF HOT PLATE TYPE OF CABLE SINGLE PHASE POWER SUPPLY Gas hot plate H05 RR F Section 3 x 0 75 mm 2 ...

Страница 15: ... 20Y 28 mbar NATURAL G20 12T 20 mbar ΣQn LPG Gas Rate 10 0 kW ΣQn NATURAL G20 Gas Rate 10 0 kW Σ Qn LPG G30 727 g h Voltage 220 240 V Frequency 50 Hz Loading 1 1 w In case of failure or cut in the cable please move away from the cable and do not touch it Moreover the device must be unplugged and not switched on Call the nearest authorized service center to fix the problem GW721X HG2VRSMXG0XS GW931...

Страница 16: ...er Sales Service Centers and authorized retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packing label The above informations give to the technical assistant the possibility to get fit spare parts and a heaven sent intervention We suggest to fill the table below MARK MODEL SERIES TECHNICAL ASSISTANCE AND SPARE PARTS 16 This appliance ...