20
7.1 STAND-BY
MODE
When the mains is attached, the control panel has following view in STAND-BY mode. Boiler
ON/OFF led is on, but no number is shown on the display:
7.2 OPERATION
MODE
When loading wood logs and starting fire, you can leave the control panel in STAND-BY mode.
When you have continuous flame, switch the control panel on by pressing ON/OFF button.
7.3 TURNING
ON
THE
PANEL
By pressing "ON/OFF button" for three seconds, control panel is switched on. LCD display is
lit and, actual boiler temperature is displayed. During first ignition, you can run the fan in
manual mode. By pressing fan manual button, you can set fan speed at minimum level to help
the fire become alive in short time.
7.4 FAN
OPERATION
MODE
SETTING
You can set the speed of the fan manually at 5 steps, or you can leave fan in "AUTO" mode,
in that case, fan speed is modulated by the electronic board in accordance with boiler set and
actual temperature.