EN 9
IMPORTANT PRECAUTION
In case of left side connection (seen from the front)
the hose must be connected by means of a clamp
fixed in the back cover opening. You will find the
fixing clamp in the accessory kit.
CONNECTION TO THE NATURAL GAS
NETWORK
Connection must be made in accordance with
standing local regulations. In case of excessive gas
pressure use pressure regulator.
CONNECTION TO THE LPG NETWORK
Special LPG coupling must be installed at the 1/2"
pipe connection.
1. Connection ending
2. Knee
3. Connection hose (connection from the right)
4. Connection hose (connection from the left)
5. Fixing clamp
6. Back cover of the cooker
IMPORTANT PRECAUTION
In case of left side connection (seen from the front)
the hose must be connected by means of a clamp
fixed in the back cover opening. You will find the
fixing clamp in the accessory kit.
CONNECTION TO THE MAINS POWER
NOTE
The combined cooker is a Class I appliance
according to the electric shock prevention degree
and must be connected to the earthed mains power
installation. The connections must be carried out by
qualified personnel only.
The appliance is fitted with power cord plug for
connection to the mains.
For appliances exceeding 2 kW of power it is
recommended to use extra feed circuit with a 16A
circuit breaker.
Power socket to which the appliance is connected
must be accessible at all times.
Faulty power cord must be immediately replaced
with a new one.
CAUTION
Make sure that the power cord is installed in such
way to avoid touching hot parts of the cooker
(exhaust at the back side, bottom part of the hob).
High temperature could cause damage to the
insulation.
BURNER SETTINGS
MINIMUM OUTPUT ADJUSTMENT
Before starting any adjustments disconnect the
appliance from the mains power supply.
Adjustments must be carried out with the tap at the
"SAVING" position.
The minimum gas output is correctly adjusted when
the inner cone of the flame arrives at the height of 3
to 4 mm.
If this is not the case, first remove the tap knob and
then tighten or loosen the screw C, depending on
whether the flame is to be reduced or increased.
For butane/propane the screw C must be fully
screwed in.
Burner
Small
Medium
Rapid
Input power (kW)
1,0
1,75
2,7
Natural gas G 20
– 20 mbar
Nozzle
diameter
(mm)
0,77
1,01
1,22
Natural gas G 20
– 13 mbar
Nozzle diameter
(mm)
0,83
1,12
1,37
Propane-butane G 30
– 30 mbar
Nozzle diameter
(mm)
0,50
0,66
0,83
Nominal flow (gram
/ hour)
72,8
127,3
196,5
CONVERSION TO ANOTHER
TYPE OF GAS
Conversion of cooker to another type of gas can be
performed only by qualified technician.
Adhere to the following procedure:
Change nozzles of all burners.
Adjust or change gas pressure regulator if
installed.
Adjust SAVING power position of hob.
Stick new gas setting label with relevant nozzle
information.
To conduct this operation, make the appropriate
entry in "The warranty card."