EN 15
CONVERSION INSTRUCTION
Conversion instruction
Adjusting for a different gas type!
Attention!
Performing of these instructions by a non-qualified engineer
can lead to dangerous situations.
The supplier is not responsible for the consequences (the
arising of a hazardous situation and/or damage to persons or
goods) caused by incorrect performance of these instructions by
engineers who are not employees of the supplier.
Consequential damage arising through inexpert performance of
these instructions is not accepted.
With this conversion-set your gas hob can be converted to different
gasses. See conversion Table.
Conversion table
Gas
type
P
mBar
Modification
Auxiliary
Semi rapid
Rapid
nozzle by-pass nozzle by-pass nozzle by-pass
G20
20
-
72
30
97
33
128
42
Convert from G20 / 20 mbar to:
G20
13
Replace nozzle & no action by-pass
84
30
115
33
145
42
G25
20
Replace nozzle & no action by-pass
77
30
105
33
134
42
G30/
G31
28-
30/37
Replace nozzle & screw in bypass
(see 3A)
50
30
65
33
85
42
G150
8
Replace nozzle & adjust bypass
(see 3C)
145
30
200
33
290
42