Dear buyer, we thank you for purchase of our product.

Prior to installation and first use of the electric water heater, please carefully read 

these instructions.

THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) 

WITH  REDUCED  PHYSICAL,  SENSORY  OR  MENTAL  CAPABILITIES,  OR  LACK  OF 

EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR 

INSTRUCTION CONCERNING USE OF THE APPLIANCE BY PERSON RESPONSIBLE 

FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH 

THE APPLIANCE.

This  water  heater  has  been  manufactured  in  compliance  with  the  relevant  standards  and  tested  by 

the  relevant  authorities  as  indicated  by  the  Safety  Certificate  and  the  Electromagnetic  Compatibility 

Certificate. The technical characteristics of the product are  listed on the label affixed between the inlet 

and outlet pipes. The installation must be carried out by qualified staff. All repairs and maintenance 

work within the water heater, e.g. lime removal or inspection/replacement of the protective anticorrosion 

anode, must be carried out by the authorised maintenance service provider.

BUILDING-IN

The water heater shall be built-in as close as possible to the outlets. When installing the water heater 

in a room with bat htub or shower tub, take into account requirements defined in IEC Standard 60364-

7-701 (VDE 0100, Part 701). It has to be fitted to the wall using appropriate rag bolts with minimum 

diameter of 8 mm. The wall with feeble charging ability must be on the spot where the water heater shall 

be hanged suitably reinforced. Due the universal construction the waterheater it can be fixed vertically 

on the wall or horizontally on the wall (output pipes must be on the left). We recommend the distance 

between the water heater and the ceiling is large enough to allow simple replacement of the MG anode 

(see dimension G in the Installation Drawing), in order to avoid unnecessary dismounting of the heater 
during the servicing intervention. 

TECHNICAL PROPERTIES OF THE APPLIANCE

Type

TG 50 N

TG 80 N

TG 100 N

TG 120 N

TG 150 N

TG 200 N

Model

TGU 50 N

TGU 80 N TGU 100 N TGU 120 N TGU 150 N TGU 200 N

Volume                                        [ l ] 

50

80

100

120

150

200

Rated pressure                     [MPa ] 

0,6

Weight / Filled with water       [kg]

24/74

30/110

34/134

38/158

44/194

65/265

Anti-corrosion protection of tank 

Enameled/Mg Anode

Connected power                    [ W ] 

2000

Voltage                                      [V

~

]

230

Heating time to 75°C 

1)

            [ h ] 

1

55

3

05

3

55

4

35

5

45

7

40

Quantity of mixed water at 40°C    [ l ] 

95

146

193

226

282

360

Energy consumption 

2)

       [kWh/24h] 1,32/1,45 1,85/2,10 2,20/2,45 2,60/2,90 3,20/3,60 2,80/3,10

1) Time for heating of the whole volume of heater with electric immersion heater by entering temperature of  
     cold water from water supply 10°C.
2)  Energy  consumption  to  maintain  stable  temperature  of  water  in  the  water  heater  65°C  at  surrounding  
      temperature 20°C, measured according to SIST EN 60379.

EN

Содержание TG 100 N

Страница 1: ...TGU 50 200 N...

Страница 2: ...ung 11 15 N vod k obsluze 27 Udh zime p r p rdorim 51 a a 23 Instructions for Use 7 35 Instrukcja obs ugi 31 Haszn lati tmutat 39 a 43 Upute za upotrebu 19 N vod na obsluhu 59 Instrukcij 63 Upute za u...

Страница 3: ...a IEC 60364 7 701 VDE 0100 Teil 701 Na steno ga pritrdite s stenskimi vijaki nominalnega premera minimalno 8mm Steno s slabo nosilnostjo morate na mestu kamor ga boste obesili primerno oja ati Grelnik...

Страница 4: ...ot 0 1 MPa nad nominalnim Izto na odprtina na varnostnem ventilu mora imeti obvezno izhod za atmosferski tlak Pri segrevanju vode v grelniku se tlak vode v kotlu zvi uje do meje ki je nastavljena v va...

Страница 5: ...nik vgraditi priklju no vrvico minimalnega preseka vsaj 1 5 mm2 H05VV F 3G1 5mm2 Ob monta i priklju nega kabla je potrebno zvezati tudi priklju ni ici kontrolne svetilke v za to predvideni priklju ni...

Страница 6: ...estiti poseben fiting T len ali izpustni ventil Grelnik lahko izpraznite tudi neposredno skozi varnostni ventil s pomikom ro ice oziroma s pomikom vrtljive kapice v polo aj kot pri preverjanju delovan...

Страница 7: ...60364 7 701 VDE 0100 Part 701 It has to be fitted to the wall using appropriate rag bolts with minimum diameter of 8 mm The wall with feeble charging ability must be on the spot where the water heate...

Страница 8: ...ircuit pressure system requires the use of pressure mixer taps For safety reasons the supply pipe must be fitted with a return safety valve or alternatively a valve of the safety class that prevents t...

Страница 9: ...ric connection the water heater must obligatorily be filled with water By first filling the tap for the hot water upon the mixing tap must be opened When the heater is filled with water the water star...

Страница 10: ...a special fitting T fitting should be mounted between the relief valve and the heater inlet pipe or a discharge tap The heater can be discharged directly through the relief valve by rotating the handl...

Страница 11: ...en Falls sie ihn in den Raum mit Badewanne oder Dusche einbauen m ssen Sie den Einbau laut Norm VDE 0100 Teil 701 IEC 364 7 701 ausf hren Das Ger t wird mittels vier Wandschrauben mit Nominaldurchmess...

Страница 12: ...erwenden F r eine sichere Betriebsweise ist unbedingt ein baumustergepruftes Sicherheitsventil an das Zulaufrohr einzubauen oder eine Sicherheitsgruppe die einen Druckanstieg von mehr als 0 1 MPa ber...

Страница 13: ...erster F llung ffnen Sie die Spindel f r warmes Wasser auf der Mischbatterie Der Warmwasserbereiter ist aufgef llt wann das Wasser durch das Ausflu rohr der Mischbatterie flie t ANSCHLU AN DAS ELEKTR...

Страница 14: ...Drehkappe des Ventils in die Position wie bei einer Funktionskontrolle entleeren Vor dem Entleeren muss der Warmwasserspeicher vom elektrischen Netz abgeschaltet und dann der Warmwasserhahn der angesc...

Страница 15: ...200 N TGU 50 N TGU 80 N TGU 100 N TGU 120 N TGU 150 N TGU200N 50 80 100 120 150 200 0 6 24 74 30 110 34 134 38 158 44 194 65 265 g 2000 230 75 1 155 305 355 435 545 740 40 95 146 193 226 282 360 2 24...

Страница 16: ...E F G TGU 50 N 561 365 185 145 461 454 130 TGU 80 N 766 565 190 345 461 454 180 TGU 100 N 926 715 200 495 461 454 260 TGU 120 N 1081 865 205 645 461 454 260 TGU 150 N 1296 1065 220 845 461 454 260 TGU...

Страница 17: ...17 1 6 2 7 3 4 5 0 5 5 0 5 5 K 1 5 2 H05VV F 3G1 5 2 RUS...

Страница 18: ...18 ryry 20 75 ry c o ry a RUS 1 2 4 L N...

Страница 19: ...standarda IEC 60364 7 701 VDE 0100 Teil 701 Na zid ga pri vrstite dvjema vijcima za zidove nominalnog promjera minimalno 8 mm Ako je zid namijenjen monta i grijalice nedostatne nosivosti moramo ga pri...

Страница 20: ...Ispusni otvor na sigurnosnom ventilu obavezno mora imati izlaz na atmosferski tlak Kod zagrijavanja vode u bojleru tlak vode se u kotlu pove ava do granice pode ene na sigurnosnom ventilu Budu i da je...

Страница 21: ...roz cijev mije alice PRIKLJU AK NA ELEKTRI NU MRE U Najprije sa raspakirane grijalice odvija em skinemo za titnu kapu sa njezina ku i ta Prije priklju enja na elektri nu mre u potrebno je u napravu za...

Страница 22: ...ri ugradnji izme u sigurnosnog ventila i dovodne cijevi naprave za grijanje namjestiti poseban fiting T komad ili ispusni ventil Napravu za grijanje mo ete tako er isprazniti neposredno kroz sigurnosn...

Страница 23: ...N TGU 80 N TGU 100 N TGU 120 N TGU 150 N TGU200N l 50 80 100 120 150 200 MPa 0 6 kg 24 74 30 110 34 134 38 158 44 194 65 265 Mq W 2000 V 230 75 1 h 155 305 355 435 545 740 40 95 146 193 226 282 360 2...

Страница 24: ...D E F G TGU 50 N 561 365 185 145 461 454 130 TGU 80 N 766 565 190 345 461 454 180 TGU 100 N 926 715 200 495 461 454 260 TGU 120 N 1081 865 205 645 461 454 260 TGU 150 N 1296 1065 220 845 461 454 260 T...

Страница 25: ...25 1 2 7 4 5 s 0 5 5 0 5 5 1 5 2 H05VV F 3G1 5 2 MK...

Страница 26: ...26 1 2 3 4 L N 20 75 y 36 MK...

Страница 27: ...0100 Teil 701 Bojler p ipevn te ke st n rouby ur en mi pro ze nomin ln ho pr m ru minim ln 8mm Pokud jej montujete na slab st nu je t eba ji nejprve pat icn zpevnit Oh va se m e diky univerz ln konstr...

Страница 28: ...nomin ln m tlakem V tokov otvor na bezpe nostn m ventilu mus m t povinn v chod do atmosf rick ho tlaku P ioh van vodyvtopn mt lesesetlakvodyzvy ujea khranici kter je nastaven na bezpe nostn m ventilu...

Страница 29: ...abudovat reduk n ventil P ed p ipojen m k elektrick s ti mus te apar t nejd ve naplnit vodou Prvn pln n provedete tak e na sm ovac baterii otev ete ventil tepl vody Apar t je napln n kdy se na odto n...

Страница 30: ...e Pro tento el se doporu uje p i zabudov n mezi bezpe nostn ventil a p tokovou trubku oh va e um stit speci ln T d l nebo v pustn ventil Oh va m ete vypr zdnit tak p mo bezpe nostn m ventilem s posun...

Страница 31: ...60364 7 701 VDE 0100 Teil 701 Nale y go zamontowa do ciany za pomoc rub o rednicy najmniej 8 mm cian o s abszej no no ci na kt rej ma by on zawieszony musimy odpowiednio wzmocni Dzi ki uniwersalnej k...

Страница 32: ...od czenia nale y na miejscach poboru wody zamontowa baterie ci nieniowe Do rury doprowadzaj cej obowi zkowo nale y zamontowa zaw r zabezpieczaj cy lub zesp zabezpieczaj cy kt ry uniemo liwia wzrost ci...

Страница 33: ...w musimy obowi zkowo wmontowa zaw r redukcyjny Przed pod czeniem elektrycznym podgrzewacz wody nale y nape ni wod Podczas pierwszego nape niania przekr ci uchwyt ciep ej wody na baterii Podgrzewacz j...

Страница 34: ...obawa przed zamarzni ciem wody w podgrzewaczu nale y wod z niego wypu ci Wod z grzejnika wylewa si przez rur dop ywow grzejnika W tym celu zaleca si przed zamontowaniem grzejnika umieszczeniespecjaln...

Страница 35: ...G 200 N TGU 50 N TGU 80 N TGU 100 N TGU 120 N TGU 150 N TGU200N 50 80 100 120 150 200 0 6 24 74 30 110 34 134 38 158 44 194 65 265 g W 2000 V 230 75 1 155 305 355 435 545 740 40 95 146 193 226 282 360...

Страница 36: ...U 50 N 561 365 185 145 461 454 130 TGU 80 N 766 565 190 345 461 454 180 TGU 100 N 926 715 200 495 461 454 260 TGU 120 N 1081 865 205 645 461 454 260 TGU 150 N 1296 1065 220 845 461 454 260 TGU 200 N 1...

Страница 37: ...37 1 6 2 7 4 H 5 T e 0 5 5 bar e 0 5 5 bar c e 1 5mm2 H05VV F 3G1 5mm2 BG...

Страница 38: ...38 1 2 3 4 L N e e e 20 75 y e a BG...

Страница 39: ...ert k t legal bb 8 mm n vleges tm r j csavarral er s ts k a falra A v zmeleg t csak olyan falra szerelhet fel amely alkalmas a v zzel felt lt tt k sz l k t meg nek biztons gos megtart s ra A v zmeleg...

Страница 40: ...kaz nban a nyom s a nomin lis rt kn l 0 1 MPa n l magasabbra emelkedjen A biztons gi szelepen l v kifoly cs nek rendelkeznie kell lef v csonkkal V zmeleg t s k zben a bojlerban a biztons gi szelepben...

Страница 41: ...gel z en k telez a v zmeleg t v zzel t rt n felt lt se Az els felt lt sn l a kever csaptelep melegv z csapj t ki kell nyitni Ha a v zmeleg t fel van t ltve v zzel akkor a kever csaptelep kifoly cs v n...

Страница 42: ...v n kereszt l t rt nik E c lb l be p t skor aj nlatos a biztons gi szelep s a v zmeleg t befoly cs ve k z egy k l n szerelv nyt T idom vagy leereszt szelepet szerelni A v zmeleg t k zvetlen l a bizton...

Страница 43: ...TGU 50 N TGU 80 N TGU 100 N TGU 120 N TGU 150 N TGU200N 50 80 100 120 150 200 0 6 24 74 30 110 34 134 38 158 44 194 65 265 W 2000 230 75 1 155 305 355 435 545 740 40 95 146 193 226 282 360 2 24 1 32 1...

Страница 44: ...F G TGU 50 N 561 365 185 145 461 454 130 TGU 80 N 766 565 190 345 461 454 180 TGU 100 N 926 715 200 495 461 454 260 TGU 120 N 1081 865 205 645 461 454 260 TGU 150 N 1296 1065 220 845 461 454 260 TGU...

Страница 45: ...45 1 6 2 7 3 4 5 0 5 5 0 5 5 1 5mm2 H05VV F 3G1 5mm2 SRP...

Страница 46: ...46 y y y 20 75 a y fiting 36 y o 1 2 3 4 L N SRP...

Страница 47: ...C 60364 7 701 VDE 0100 Teil 701 Na zid ga pri vrstite dvjema vijcima za zidove nominalnog promjera minimalno 8 mm Ako je zid namijenjen monta i grijalice nedostatne nosivosti moramo ga primjereno oja...

Страница 48: ...le Ispusni otvor na sigurnosnom ventilu obavezno mora imati izlaz na atmosferski tlak Kod zagrijavanja vode u bojleru tlak vode se u kotlu pove ava do granice pode ene na sigurnosnom ventilu Budu i da...

Страница 49: ...e kroz cijev mije alice PRIKLJU AK NA ELEKTRI NU MRE U Najprije sa raspakirane grijalice odvija em skinemo za titnu kapu sa njezina ku i ta Prije priklju enja na elektri nu mre u potrebno je u napravu...

Страница 50: ...o pri ugradnji izme u sigurnosnog ventila i dovodne cijevi naprave za grijanje namjestiti poseban fiting T komad ili ispusni ventil Napravu za grijanje mo ete tako er isprazniti neposredno kroz sigurn...

Страница 51: ...at e standardit IEC 60364 7 701 VDE 0100 Teil 701 E p rforcini n mur me vidha p r muri me diamet r nominal minimalisht 8mm Murin me bajtje t dob t n t cilin keni nd rmend t varni bojlerin duhet t forc...

Страница 52: ...nominale Hap sira e daljes n ventilin sigurues nevojitet t p rmban dalje n presion atmosferik Te nxehja e ujit n bojler shtypja e ujit rritet deri te kufiri ku asht ajo e rregulluar n ventilin sigurue...

Страница 53: ...5 MPa 5 bar patjet r duhet t instaloni ventil reduktiv Para aderimit elektrik s pari duhet mbushur bojlerin me uj Te mbushja e par elni dor z n p r uj t ngroht n baterin p rziese Bojleri asht i mbush...

Страница 54: ...til shkarkues Ngroh sin mund t zbrazni edhe drejtp rdrejt n p rmjet t ventilit sigurues me l vizjen e dor z s resp kapakut rrotullues t ventilit n pozicion si tek kontrollimi i funksionimit Paraprakis...

Страница 55: ...a montarea boilerului pe perete folosi i buloane cu diamterul nominal de minim 8 mm Peretele cu rezisten respectiv portan redus va trebui n prealabil consolidat n mod corespunz tor n locul unde inten...

Страница 56: ...curgere a ventilului de siguran trebuie s aib n mod obligatoriu ie ire la presiunea atmosferic nc lzirea apei din boiler duce la cre terea presiunii p n la limita fixat prin ventilul de siguran ntruc...

Страница 57: ...te 0 5 MPa 5 bar vor trebui montate ventile de reducere nainte de a fi bran at la re eaua electric boilerul va trebui obligatoriu umplut cu ap La prima umplere se va deschide robinetul de ap cald al...

Страница 58: ...ntil de scurgere Boilerul poate fi golit i n mod direct prin ventilul de siguran prin ac ionarea manetei respectiv a c p celului rotativ al ventilului n acela i fel ca atunci c nd se verific modul de...

Страница 59: ...o iadavky normy IEC 60364 7 701 VDE 0100 as 701 Na stenu ho pripevn te n stenn mi skrutkami s minim lnym nomin lnym priemerom 8 mm Stenu so slabou nosnos ou mus te na mieste kam ho pripevn te vhodne s...

Страница 60: ...pe nostn ventil zabra uj ci zv eniu tlaku v kotle o viac ako 0 1 MPa nad nomin lnym tlakom V pustn otvor na bezpe nostnom ventile mus povinne ma v stup na atmosf rick tlak Pri zohrievan vody v ohrieva...

Страница 61: ...nie reduk n ho ventilu Pred zapojen m do elektrickej siete mus te do ohrieva a bezpodmiene ne najsk r napusti vodu Pri prvom nap an otvorte p ku na tepl vodu na mie acej bat rii Ohrieva je napusten ke...

Страница 62: ...okov hadicu ohrieva a Za t mto elom odpor ame pri zabudovan medzi bezpe nostn ventil a pr tokov hadicu ohrieva a umiestni osobitn fiting T kus alebo vyp ac ventil Ohrieva m ete vypr zdni aj priamo cez...

Страница 63: ...C 60364 7 701 VDE 0100 Teil 701 reikalavim Turi b ti pritaisomas prie sienos naudojant tinkamus kietosios sluoksniuotosios klinties var tus su nema esniu nei 8 mm diametru D l universalios konstrukcij...

Страница 64: ...lin vo tuv kuris nustatytas 0 1 MPa sl giui arba apsaugin grup kuri apsaugot apsaugot nuo vir sl gio susidarymo bake Vandeniui ylant sl gis ildytuve kyla iki nustatyto 0 1 MPa Apsauginio vo tuvo i vad...

Страница 65: ...a u pildyti ildytuv vandeniu Tam reikia atsukti kar to vandens padavimo iaup ildytuvas bus pilnai u pildytas kai i kar to vandens iaupo prad s b gti vanduo PAJUNGIMAS PRIE ELEKTROS TINKLO Prie prijung...

Страница 66: ...r laik nesinaudoti vandens ildytuvu Ir j s i vengsite vandens ildytuvo u alimo Vanduo i ildytuvo i teka per ildytuvo nutekamaj vamzd Tod l patartina montuojant ildytuv tarp apsauginio vo tuvo ir nutek...

Страница 67: ...67...

Страница 68: ...04 2010 189796...

Отзывы: