Key:
1 - Thermostat
2 - Bimetal fuse
3 - Heating element
(2 x 1000 W)
4 - Light indicator
5 - Connector
L - Phase conductor
N - Neutral conductor
- Earth conductor
WARNING: The appliance must be disconnected from the power supply prior to doing
anything that requires you to open the body of the water heater!
OPERATION AND MAINTENANCE
After the connection to water and electric network the heater is ready for use.
By turning the knob of thermostat at the front side of the protecting cover, the wished temperature of water between
25°C and 75°C is chosen. We recommend the adjustment of the knob to the position “E”. Such an adjustment is the
most economic; with it the temperature of water shall be about 55°C, the excretion of lime-stone and thermal loss shall
be smaller as by adjustment to higher temperature.
The operation of electric immersion heaters is shown by pilot light. On the perimeter of the water heater there is a
built-in thermometer which is showing the temperature of water. When the heater shall not be used during a longer
time, its contents must be protected against freezing so that the power supply (electricity) shall not be switched off,
but the thermostat knob shall be adjusted to the position “*”. With this adjustment the heater shall maintain the water
temperature by about 10°C. But when the heater is switched-off from the electric network, at risk for freezing, the water
must be emptied from it.
Before draining water heater should be disconnected from main supply. Than hot water valves on taps should be
opened. Water heater is to be drained through inlet connection. For this purpose it is recommendable to put special
fitting or a drain valve between inlet connection of water heater and safety valve. If this is not the case water can be
drained directly through safety valve by putting the lever or screw cap of safety valve to “Test” position. After draining
through inlet pipe there is small quantity of residual water which is to be drained by taking off of heating flange.”
The outside of the water heater is cleaned by a mild solution of detergent, The solvents or rough cleaning means should
not be used.
By regular service check of impeccable operation must be assured and a long lifetime of the water heater. The first
check must be performed by an authorised service workshop after about two years after the first connection. At check,
the use of anti-corrosion protecting anode is checked and if necessary lime stone must be cleaned which with regard to
the quality, quantity and temperature of the water used is gathered in the inside of the water heater. Service workshop
shall after check recommend also the date of next check of the water heater with regard to the established results.
Never try to repair any possible faults of the water heater by yourself, but inform about it the
nearest authorised service workshop.
GB
Содержание GBK 100 LN/RN
Страница 1: ...GBK GBL...
Страница 13: ...13 GBK GB c GB GBK y K K a c y 1 2 3 4 5 6 7 c H T RUS...
Страница 14: ...14 1 2 3 2 x 1000 4 5 L N Ha c 25 75 E 55 B f B 10 B He B c o a RUS...
Страница 29: ...29 1 2 3 e 4 5 6 7 H T GBK GB GB GBK Zp tn veden Energetick zdroje BG...
Страница 30: ...30 BG 1 2 3 2 x 1000 W 4 5 L N e e 25 C 75 C e E e e 55 C f 10 C T e c He 2 a...
Страница 37: ...37 MK 1 2 3 4 5 6 7 H a T GBK GB GB GBK 3...
Страница 38: ...38 MK 1 2 3 2 1000 W 4 5 L N 25 75 55 10 36...
Страница 41: ...41 1 2 3 4 5 6 7 H T GBK GB GB GBK 3 mm SRB...
Страница 42: ...42 25 75 55 10 36 1 2 3 2 x 1000 W 4 5 L N SRB...
Страница 67: ...67...
Страница 68: ...766367 03 2010...