![Goot Anti-Static Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/goot/anti-static-series/anti-static-series_owners-operation-manual_2244580009.webp)
www.procontechnology.com.au
Phone: (03) 98306288
TAIYO ELECTRIC IND.CO.LTD.
B. RX-711 series only
B-1. Set the temperature display changeover switch on the left side of
the front panel to the SET side. With the switch at this position, the
temperature display shows the set temperature.
B-2. Set the power switch to ON (the I mark side).
The heater monitor lamp will light and the heater will
start to heat up. When turning the soldering station
power switch ON from OFF, “999” will be initially
displayed for approximately 10 seconds.
B-3. Set the required temperature by using the temper-
ature setting knob.
B-4. After doing the setting, when changing the switch to the
MEAS side the digital display will show the measured tempera-
ture. When the heater temperature reaches the set temperature,
the monitor lamp will flash. This indicates that the soldering unit
is ready for use.
When turning the soldering station power ON again after turning
it OFF within one hour, the temperature displayed will lower to
“000” and then will display measured temperature.
CAUTION
Do not turn the temperature setting knob beyond 480°C. By
turning the temperature setting knob clockwise toward "MAX.",
the required temperature and tip temperature can be set
beyond 480°C. It may go up to approx. 510°C. Setting beyond
500°C could result in damage to your soldering station.
NOTE
1
NOTE
2
NOTE
3
There may be a difference of 2°C between the SET and MEAS temperature
display. When the soldering station is shipped the temperature calibration
is done with the temperature display set on the SET side. With the
temperature display set on the MEAS side correction of the tip temperature
by using the temperature setting knob is not required.
When the temperature display is set on MEAS, the temperature displayed will
fluctuate from 2 to 3 degrees Celsius.
When the temperature display is set on MEAS if a heat load is placed for 10
seconds, the temperature display will not change.
Example While contacting the tip on a wet sponge, the actual tip tem-
perature will drop for 10 seconds. However the temperature shown on the
display will be the one before the tip was touched on the sponge.
The actual temperature will be shown on the display 10 seconds later. The
temperature control circuit works to recover the set temperature when the tip
is cooled immediately even though the display of measured temperature is
not changed.