English
•
Owner´s manual
61
Top up if necessary.
EVERY 500 HOURS WORK
1) Change the oil in the gearbox housing as indicated in point 1 (after the first 50 work hours), (Fig. 20-
21).
Routine adjustments
NOTE:
The column cover of the handle-bars (A) must be demounted by unscrewing the relative bolts
(Fig. 24-25) to use the adjusters of the diff lock control lever (5) and the right and left brake levers (6-7)
(Fig. 24-25).
Fig. 24 - Demounting the handle-bar column cover to
regulate the lever adjusters.
Fig. 25 - Control levers on the handle-bars.
Remove the column cover and adjust in the following way:
1) Diff lock lever (5), (Fig. 24)
If diff lock (5) lever play increases, it can be adjusted in the following way:
a) Slacken off the check nut (B) of the adjuster (C).
b) Use the adjuster (C) to recover lever play.
c) Re-tighten the check nut (B).
FUEL AND LUBRIFICANTS TABLE*
Specif.
Temp.
Type of
lubricant
Q. TY l.
Replace after
GEARBOX
HOUSING
AGP L3
Multigrade
SAE 80W/90
No detergent
4
50 h (1º Change)
500 h (Nexts)
Lubricators
-
-
EPX-2 MOLY
-
50 h
Fuel Tank
Gasoline / Petrol
6,5 l.
-
* For the diesel model consult diesel engine manual
8. ELECTRICAL SYSTEM
Electrical system*
*According to models
ATTENTION
- Disconnect the battery earth cable before working on any electrical component.
- Never recharge the battery near a naked flame or in an enclosed space. There must always be sufficient
ventilation to prevent accidental explosions.
- Ensure you always connect the battery cables to the correct poles (positive to positive (+) and negative
to negative (-)).