Goodwe GW10KN-DT Скачать руководство пользователя страница 7

Inverter

Positive connector

Negative connector

Figure

 

3.4.3-1

Negative connector

Positive connector

Inverter

Special tools are used to stitching

Note: For installation of Amphenol connectors, These two limit buckles of Amphenol connectors are only for

installation positioning use, can’t crimp the wire.

MC4 series

AMPHENOL series

Figure

 

3.4.3-2

Limit buckle can’t

crimp the wire

DC Cable specification please refer to Figure

 

3.4.3-3

.

Value

4

~

5mm

2

.

5

~

4mm

²

7mm

 

around

Grade

  

Description

  

A

      

O.D.

  

B

      

Conductor Material

 

Sectional Area

  

C

       

Bare Wire Length

Figure

 

3.4.3-3

A

B

C

*DC Cable should be use dedicated PV cable

.

(

1) Gateway communication  connection procedure:

Remove the waterproof kit of gateway cover with screwdriver.

Remove the screw cap of the cable gland.

Remove the one-hole sealing ring.

Insert the gateway cable through the components as the followings: screw cap, one-hole sealing ring, insulation body and sheet 

metal parts.

Fasten

 

the

 

cable

 

as

 

Figure

 

shown

figure

 

3

.

4

.

4

-

2.

Connect the compressed cable to the bulit-in communication interface of inverter.

Fasten the gateway waterproof kit to inverter.

Fasten the screw cap of the cable gland.

INVERTER

Figure

 

3

.

4

.

4

-

1

3

.

4

.

4

 

Gateway connect

The gateway port connects to tigo’s gateway port. Port1 connects to A, Port2 connects to B, Port3 connects to +, Port4 

connects to -.

Gateway connection please refer to Figure 3

.

4

.

4

-

1

.

10

SDT4~10KW

RS485 

Communication

Board

Screw cap

Single hole
seal ring

The 

insulator

Nut

Cables

Screw

1 2 3 

1 2 3

 

Figure

 

3

.

4

.

4

-

2

1  
2    485A
3    485B

GND_COM

1    A (gateway)
2    B (gateway)
3    + (gateway)
4    -  (gateway)

Содержание GW10KN-DT

Страница 1: ...goodwe com cn service au goodwe com cn GoodWe Australia www goodwe com cn service nl goodwe com cn GoodWe Netherlands GoodWe UK www goodwe co uk enquiries goodwe co uk Note The information above is s...

Страница 2: ...verview and Packaging 3 3 Inverter Installation 3 4 Electrical Connection 4 1 LED Lights 4 2 User Interface and Controls 4 3 Error Code 4 4 WiFi Reset WiFi Reload 4 5 Power limiting function setting 0...

Страница 3: ...imum rated input voltage of the inverter otherwise the inverter may be damaged and the warranty will be annulled When exposed to sunlight the PV array will generate very high voltage which will cause...

Страница 4: ...tion Installation position should be selected based on the following aspects The installation method and mounting location must be suitable for the inverter s weight and dimensions Mount on a solid su...

Страница 5: ...Add breaker or fuse to AC side the specification should be more than 1 25 times of rated AC output current 3 The PE line of inverter should be connected to the earth make sure the impedance of neutral...

Страница 6: ...risk of shock hazard if the requirement of minimum resistance is not met 5 Positive shall be red negative shall be black 3 4 2 AC circuit breaker and leakage current protection device In order to ensu...

Страница 7: ...gateway cover with screwdriver Remove the screw cap of the cable gland Remove the one hole sealing ring Insert the gateway cable through the components as the followings screw cap one hole sealing ri...

Страница 8: ...lation you need enable Power Limit function and set export power limiting value on LCD via button according to next chapter 4 2 3 4 7 Earth FauItAlarm Figure3 4 6 1 3 4 6 Power Limiting Device DRED In...

Страница 9: ...012 01 18 Utility Loss 13 12 25 2012 03 25 Set Time 13 12 25 2012 03 25 Language English WiFi Reset Successful WiFi Reset Failed Year Mode Month Mode Day Mode Hour Mode Error Log Date Time Language Hi...

Страница 10: ...area shows the maximum rated power generation each hour for inverter This area can display information in different modes There are 5 display modes in total real time mode hour mode day mode month mod...

Страница 11: ...ENTER the chosen safety will be set If there is no EXACTLY proper country code please choose 50Hz Grid Default or 60Hz Grid Default accordingly the safety you This function is used for special requir...

Страница 12: ...inputs from the PV generator and check the peripheral AC system 3 When the problem is cleared reconnect the PV panel and check the Inverter status 4 Contact local service office for help if the probl...

Страница 13: ...40us 40A 40us 40A 40us 6 Technical Parameters and Block Diagram 6 1 Technical Parameters GW4000 DT GW5000 DT GW6000 DT GW8000 DT GW9000 DT GW10KN DT Operating Altitude m User Interface Communication S...

Страница 14: ...with two fans on its left side The fan intakes and handle covers should be cleaned yearly with a vacuum cleaner For more thorough cleaning completely remove the fans Disconnect the AC breaker firstly...

Страница 15: ...8 Certificates 25...

Отзывы: