Goodwe GW10KN-DT Скачать руководство пользователя страница 4

SDT4~10KW

 

inverter

 

illustration

.

Positive DC Plug:SDT4~10KW 2 pairs.

Negative DC Plug:SDT4~10KW 2 pairs.

4PIN terminal: SDT4~10KW: 1pcs for tigo gateway communication

The installation position shall

 

not prevent access to the disconnection means.

1. PV input terminals
2. Waterproof vent 
3. DC Switch(Optional)
4. Wi-Fi&LAN
5. RS485 & GATEWAY
6. 
7. LED lights 
8. LCD display

9. Buttons

AC output terminal

① ② ③

④ ⑤

Expansion screw

×

6

Flat

 

Head

 

Screw

AC Terminal

 

X6

 

AC Junction 

 Box screw

 

 

AC

 

connector

×

1

3.2

.

2 Package

Inverter

×

1

Wall-mounted

Bracket

×

1

Positive DC Plug

Negative

 

DC Plug

User manual×1

Quick Installation

Guide×1

User

manual

Fast installation

 instructions

3.3 Inverter Installation

3.3.1 Selecting the Installation Position

Installation position should be selected based on the following aspects:

● 

The installation method and mounting location must be suitable for the inverter's weight and dimensions.

● 

Mount on a solid surface.

● 

Select a well ventilated place sheltered from direct sun radiation.

● 

 

point downwards.

 

Install vertically or tilted backward by max 15°. The device cannot be installed with a sideways tilt. The connection area must 

Refer to Figure 3.3.1-1.

● 

In consideration of heat dissipation and convenient dismantlement, the minimum clearances around the inverter should be no less 

than the following value:

Figure

 

3.3.1-1

 

AC Junction Box 

:

RS485

 

6pcs

WiFi

 

12

 

screw 

pcs.

Flat

 

Head

 

Screw: 2pcs(optional).

3.2.1 Inverter Overview

Antenna

×

1

4PIN terminal

×

1

3PIN terminal

×

1

Upward----------200mm

Downward-------500mm

Front--------------300mm

Both sides-------500mm

Figure

 

3.3.1-2

200mm

500mm

500mm

500mm

300mm

3PIN terminal: SDT4~10KW: 1pcs for RS485 communication

Содержание GW10KN-DT

Страница 1: ...goodwe com cn service au goodwe com cn GoodWe Australia www goodwe com cn service nl goodwe com cn GoodWe Netherlands GoodWe UK www goodwe co uk enquiries goodwe co uk Note The information above is s...

Страница 2: ...verview and Packaging 3 3 Inverter Installation 3 4 Electrical Connection 4 1 LED Lights 4 2 User Interface and Controls 4 3 Error Code 4 4 WiFi Reset WiFi Reload 4 5 Power limiting function setting 0...

Страница 3: ...imum rated input voltage of the inverter otherwise the inverter may be damaged and the warranty will be annulled When exposed to sunlight the PV array will generate very high voltage which will cause...

Страница 4: ...tion Installation position should be selected based on the following aspects The installation method and mounting location must be suitable for the inverter s weight and dimensions Mount on a solid su...

Страница 5: ...Add breaker or fuse to AC side the specification should be more than 1 25 times of rated AC output current 3 The PE line of inverter should be connected to the earth make sure the impedance of neutral...

Страница 6: ...risk of shock hazard if the requirement of minimum resistance is not met 5 Positive shall be red negative shall be black 3 4 2 AC circuit breaker and leakage current protection device In order to ensu...

Страница 7: ...gateway cover with screwdriver Remove the screw cap of the cable gland Remove the one hole sealing ring Insert the gateway cable through the components as the followings screw cap one hole sealing ri...

Страница 8: ...lation you need enable Power Limit function and set export power limiting value on LCD via button according to next chapter 4 2 3 4 7 Earth FauItAlarm Figure3 4 6 1 3 4 6 Power Limiting Device DRED In...

Страница 9: ...012 01 18 Utility Loss 13 12 25 2012 03 25 Set Time 13 12 25 2012 03 25 Language English WiFi Reset Successful WiFi Reset Failed Year Mode Month Mode Day Mode Hour Mode Error Log Date Time Language Hi...

Страница 10: ...area shows the maximum rated power generation each hour for inverter This area can display information in different modes There are 5 display modes in total real time mode hour mode day mode month mod...

Страница 11: ...ENTER the chosen safety will be set If there is no EXACTLY proper country code please choose 50Hz Grid Default or 60Hz Grid Default accordingly the safety you This function is used for special requir...

Страница 12: ...inputs from the PV generator and check the peripheral AC system 3 When the problem is cleared reconnect the PV panel and check the Inverter status 4 Contact local service office for help if the probl...

Страница 13: ...40us 40A 40us 40A 40us 6 Technical Parameters and Block Diagram 6 1 Technical Parameters GW4000 DT GW5000 DT GW6000 DT GW8000 DT GW9000 DT GW10KN DT Operating Altitude m User Interface Communication S...

Страница 14: ...with two fans on its left side The fan intakes and handle covers should be cleaned yearly with a vacuum cleaner For more thorough cleaning completely remove the fans Disconnect the AC breaker firstly...

Страница 15: ...8 Certificates 25...

Отзывы: