11.3 HEPA FILTER FOR WORKING AIR EXHAUST (ITEM #8 ON FIG. 1SEE SECTION 8
FOR ILLUSTRATION)
1. Disconnect the power cable from the outlet.
2. Unscrew the six hex nuts securing the lower section of the power head to the lid
3. Remove and discard the old HEPA filter.
4. Carefully inspect the seal gasket on the HEPA filter. Replace gasket if defective.
5. Place the new filter on the lid.
6. Securely fasten the lower section of the power head to the lid using the six hex nuts.
7. Dispose of the contaminated filter according to government regulations. (If applicable)
11.4 HEPA FILTER FOR WORKING AIR INTAKE (ITEM #3 ON FIG. 1 SEE SECTION 7 FOR
ILLUSTRATION)
1. Disconnect the power cable from the outlet.
2. Disengage the latches and remove the power head from the recovery tank.
3. Remove the safety filter
4. Unscrew the hex nut securing the HEPA filter to the underside of the lid.
5. Discard the old HEPA filter.
6. Carefully inspect the seal gaskets for wear and breaks. Replace gaskets if defective.
7. Insert the new HEPA filter
8. Securely fasten the HEPA filter using the hex nut.
9. Place back the safety filter
10. Dispose of the contaminated filter according to government regulations. (If applicable)